TIMEPOWER TP120 (k = 0.1) conductivity analyzer
TIMEPOWER-
ECscan30 pen conductivity meter Conductivity Detector TDS
$ 155.00 -
FANGZHOU DDS-302 + high-precision pure water conductivity meter
$ 747.00 -
HANNA HI98318 GroLine EC-TDS- ℃ Tester
$ 201.00 -
DDKSIC DJS-0.01VTK Low Range Conductivity Detector electrode set for pure water, ultrapure water distillation water, etc
$ 216.00 -
Qiwei DDBJ-350 conductivity meter (portable microcomputer model) automatic temperature compensation
$ 169.00
Introduction
TP120 conductivity analyzer is a new generation of high-end instrument with Chinese and English menu-based operation, full intelligence, multi-function, high measurement performance, strong environmental adaptability, etc., which can be used for continuous monitoring of conductivity values in solutions in various industries.

Features
The instrument adopts high-precision A/D conversion and microprocessor microprocessor technology, which can realize various functions such as conductivity measurement, temperature measurement, automatic temperature compensation, and automatic range conversion.
It adopts professional chip placement process and integrated high-integration circuit design.
The current output adopts photoelectric coupling isolation technology, which has strong anti-interference ability and can realize remote transmission. It has good electromagnetic compatibility.
Chinese menu-style operation, easy to understand, easy to operate.
Data cycle storage function, automatic removal of overflow data, easy operation, simple query, power failure data storage time of more than 10 years.
IP65 protection level, suitable for outdoor use.
The standard output signal type is optional, and the alarm relay can be set arbitrarily.
TIMEPOWER TP120(k=0.1) Conductivity analyzerSpecifications
| LIST | VALUE |
|---|---|
| Measurement range | 0.00 to 30.00 μS/cm and 0.0 to 300.0 μS/cm |
| Measurement error | ±2.5% F.S |
| Resolution | 0.001μS/cm |
| Temperature compensation range | 0~60℃ |
| Dimensions | 145*120*150mm |
| Weight | 0.64kg |
| Display | 128X64 dot matrix LCD, Chinese display |
| Repeatability | ≤1% |
| Temperature sensor | Pt1000 |
| Water sample temperature | 5~60℃ |
| water sample pressure | <0.6 Mpa |
| Operating temperature | 5~45℃ |
| Operating humidity | ≤ 90% RH (non-condensing) |
| Storage temperature | -25~55℃ |
| Protection level | IP65 |
| Power down save | > 10 years |
| Current Output | 0~10mA, 0~20mA, 4~ 20mA optional, load < 300Ω |
| Alarm relay | 2 normally open points can be set arbitrarily, AC 220V 3A/DC 30V 3A |
| output load Capacity | ≤750Ω |
| Output Accuracy | 1%F.S |
| Relay load Capacity | AC 250V 5A/DC 30V 5A |
| Power Supply | AC (85~ 265) V Frequency (45~ 65) Hz |
| Power | ≤ 15W |
| opening size | 138mm×138mm |
TIMEPOWER TP120(k=0.1) Conductivity analyzer Packing list
Host X1, conductivity composite electrode (k = 0.1) X1, 5 meters X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveJJG 2059-2014
- ActiveGB/T 13580.3-1992
- ActiveGB/T 6539-1997
- ActiveGB/T 18932.15-2003
- ActiveGB/T 11007-2008
- ActiveGB/T 23977-2009
- ActiveGB/T 20245.3-2013
- ActiveGB/T 41079.2-2022
- ActiveGB/T 6908-2018
- ActiveGB/T 7977-2007
- ActiveGB/T 32697-2016
- ActiveGB/T 33328-2016
- ActiveISO 21318-2007
- ActiveISO 9944-1990
- ActiveGB/T 27503-2011
- ActiveGB/T 27502-2011
- ActiveJB/T 9366-1999
- ActiveJB/T 6855-1993
- ActiveASTM D 4399-90-2017
- AbolishHG/T 2-1047-1977


TP120(k=0.1)