TIMEPOWER TP120 (k = 10) conductivity analyzer
TIMEPOWER-
Qiwei DDS-11A microcomputer conductivity meter 0~1999μs/cm
$ 130.00 -
LEICI DJS-1-L Conductivity Detector electrode (platinum black) MiniDIN 8 core
$ 105.00 -
FANGZHOU FZ-702 Conductivity Detector electrode 0.2-200 µS/cm
$ 178.00 -
LEICI DDB-305A Portable Conductivity Meter 1.0 level conductivity TDS temperature value
$ 431.00 -
Bante520-DL portable conductivity meter for measurement of pure water
$ 366.00
Introduction
TP120 conductivity analyzer is a new generation of high-end instrument with Chinese and English menu-based operation, full intelligence, multi-function, high measurement performance, strong environmental adaptability, etc., which can be used for continuous monitoring of conductivity values in solutions in various industries.

Features
The instrument adopts high-precision A/D conversion and microprocessor microprocessor technology, which can realize various functions such as conductivity measurement, temperature measurement, automatic temperature compensation, and automatic range conversion.
It adopts professional chip placement process and integrated high-integration circuit design.
The current output adopts photoelectric coupling isolation technology, which has strong anti-interference ability and can realize remote transmission. It has good electromagnetic compatibility.
Chinese menu-style operation, easy to understand, easy to operate.
Data cycle storage function, automatic removal of overflow data, easy operation, simple query, power failure data storage time of more than 10 years.
IP65 protection level, suitable for outdoor use.
The standard output signal type is optional, and the alarm relay can be set arbitrarily.
TIMEPOWER TP120(k=10) Conductivity analyzerSpecifications
| LIST | VALUE |
|---|---|
| Measurement range | 0~3000 μS/cm and 0~30000 μS/cm |
| Measurement error | ±2.5% F.S |
| Resolution | 0.001μS/cm |
| Temperature compensation range | 0~60℃ |
| Dimensions | 145*120*150mm |
| Weight | 0.64kg |
| Display | 128X64 dot matrix LCD, Chinese display |
| Repeatability | ≤1% |
| Temperature sensor | Pt1000 |
| Water sample temperature | 5~60℃ |
| water sample pressure | <0.6 Mpa |
| Operating temperature | 5~45℃ |
| Operating humidity | ≤ 90% RH (non-condensing) |
| Storage temperature | -25~55℃ |
| Protection level | IP65 |
| Power down save | > 10 years |
| Current Output | 0~10mA, 0~20mA, 4~ 20mA optional, load < 300Ω |
| Alarm relay | 2 normally open points can be set arbitrarily, AC 220V 3A/DC 30V 3A |
| output load Capacity | ≤750Ω |
| Output Accuracy | 1%F.S |
| Relay load Capacity | AC 250V 5A/DC 30V 5A |
| Power Supply | AC (85~ 265) V Frequency (45~ 65) Hz |
| Power | ≤ 15W |
| opening size | 138mm×138mm |
TIMEPOWER TP120(k=10) Conductivity analyzer Packing list
Host X1, conductivity composite electrode (k = 10) X1, 5 meters X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveJJG 2059-2014
- ActiveGB/T 13580.3-1992
- ActiveGB/T 6539-1997
- ActiveGB/T 18932.15-2003
- ActiveGB/T 11007-2008
- ActiveGB/T 23977-2009
- ActiveGB/T 20245.3-2013
- ActiveGB/T 41079.2-2022
- ActiveGB/T 6908-2018
- ActiveGB/T 7977-2007
- ActiveGB/T 32697-2016
- ActiveGB/T 33328-2016
- ActiveISO 21318-2007
- ActiveISO 9944-1990
- ActiveGB/T 27503-2011
- ActiveGB/T 27502-2011
- ActiveJB/T 9366-1999
- ActiveJB/T 6855-1993
- ActiveASTM D 4399-90-2017
- AbolishHG/T 2-1047-1977


TP120(k=10)