TIMEPOWER TP121 (k = 10) conductivity analyzer
TIMEPOWER-
HANNA HI98318 GroLine EC-TDS- ℃ Tester
$ 201.00 -
ECscan10H-E pen conductivity meter 0.1~ 19.99mS/cm
$ 127.00 -
LEICI DDBJ-350 Conductivity Meter Class 1 Portable conductivity Tester
$ 521.00 -
LEICI DJS-1DF Conductivity Detector electrode (platinum black) three-core aviation plug (waterproof type)
$ 97.00 -
LEICI DJS-10C Conductivity Detector electrode
$ 94.00
Introduction
TP121 conductivity analyzer has the characteristics of Chinese and English menu-based operation, full intelligence, multi-function, high measurement performance, strong environmental adaptability, etc., which can be used for continuous monitoring of conductivity values in solutions in various industries.

Features
The instrument adopts high-precision A/D conversion and microprocessor microprocessor technology, which can realize various functions such as conductivity measurement, temperature measurement, automatic temperature compensation, and automatic range conversion.
The components are integrated into a single circuit board, eliminating the need for complex function switches, adjustment knobs and potentiometers.
The current output adopts photoelectric coupling isolation technology, which has strong anti-interference ability and can realize remote transmission. It has good electromagnetic compatibility.
The standard output signal type is optional, and the alarm relay can be set arbitrarily.
The display in Chinese and English can be switched, which is easy to understand and easy to operate.
Data cycle storage function, automatic removal of overflow data, easy operation, simple query, power failure data storage time of more than 10 years.
Waterproof and dustproof design: IP65 protection level, suitable for outdoor use.
TIMEPOWER TP121(k=10) Conductivity analyzerSpecifications
| LIST | VALUE |
|---|---|
| Measurement range | 20μS/cm~20mS/cm |
| Measurement error | ±2.5% F.S |
| Resolution | 0.01μS/cm |
| Temperature compensation range | 0~60℃ |
| Dimensions | 98*130*98mm |
| Weight | 0.5kg |
| Display | 1128X64 dot matrix LCD, Chinese and English display can be switched |
| Repeatability | ≤1% |
| Temperature sensor | Pt1000 |
| Water sample temperature | 5~60℃ |
| water sample pressure | <0.6 Mpa |
| Operating temperature | 5~45℃ |
| Operating humidity | ≤ 90% RH (non-condensing) |
| Storage temperature | -25~55℃ |
| Protection level | IP65 |
| Power down save | > 10 years |
| Current Output | 0~10mA, 0~20mA, 4~ 20mA optional, load < 300Ω |
| Alarm relay | 2 normally open points can be set arbitrarily, AC 220V 3A/DC 30V 3A |
| output load Capacity | ≤750Ω |
| Output Accuracy | 1%F.S |
| Relay load Capacity | AC 250V 5A/DC 30V 5A |
| Power Supply | AC (85~ 265) V Frequency (45~ 65) Hz |
| Power | ≤ 15W |
| opening size | 94mm×94mm |
TIMEPOWER TP121(k=10) Conductivity analyzer Packing list
Host X1, conductivity composite electrode (k = 10) X1, 5 meters X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveJJG 2059-2014
- ActiveGB/T 13580.3-1992
- ActiveGB/T 6539-1997
- ActiveGB/T 18932.15-2003
- ActiveGB/T 11007-2008
- ActiveGB/T 23977-2009
- ActiveGB/T 20245.3-2013
- ActiveGB/T 41079.2-2022
- ActiveGB/T 6908-2018
- ActiveGB/T 7977-2007
- ActiveGB/T 32697-2016
- ActiveGB/T 33328-2016
- ActiveISO 21318-2007
- ActiveISO 9944-1990
- ActiveGB/T 27503-2011
- ActiveGB/T 27502-2011
- ActiveJB/T 9366-1999
- ActiveJB/T 6855-1993
- ActiveGB/T 5209-1985
- ActiveASTM D 4399-90-2017


TP121(k=10)