FANGZHOU FZ-703W Conductivity Detector electrode (bright) 2.0-200 µS/cm
$ 133.00 -
BANTE IE-50HT Industrial Conductivity Detector electrode for measurement of high Conductivity Detector liquid conductivity value
$ 134.00 -
Bante531-DH Portable Conductivity Meter for measurement of high Conductivity Detector liquids
$ 347.00 -
Bante520-S portable conductivity meter for routine applications
$ 256.00 -
HANNA HI98312 High Range EC-TDS- ℃ Meter
$ 267.00
Introduction
TP122 conductivity analyzer is a new generation of our company's new generation of all-Chinese microcomputer high-end instrument, with full Chinese display, Chinese menu-based operation, high intelligence, multi-function, high measurement performance, strong environmental adaptability and other characteristics. It can be widely used in thermal power, chemical fertilizer, metallurgy, environmental protection, biochemical, food and tap water and other solutions for continuous monitoring of conductivity values.

Features
It is displayed in Chinese and English, and it is easy to operate
The instrument adopts high-precision AD conversion and microprocessor microprocessor technology
The components are integrated into a single circuit board, eliminating the need for complex function switches, adjustment knobs and potentiometers
The current output adopts photoelectric coupling isolation technology, which has strong anti-interference ability and good electromagnetic compatibility
IP65 protection level, suitable for outdoor use
Multi-parameter display at the same time to display conductivity, temperature, time and status
The standard output signal type is optional, and the alarm relay can be set arbitrarily
TIMEPOWER TP122 Conductivity analyzerSpecifications
| LIST | VALUE |
|---|---|
| Measurement range | 0~1000mS/cm |
| Measurement error | ±2.5% F.S |
| Resolution | 0.1mS/cm |
| Temperature compensation range | 0~60℃ |
| Dimensions | 145*120*150mm |
| Weight | 0.64kg |
| Display | 128 × 64 dot matrix LCD, Chinese display |
| Temperature sensor | Pt1000 |
| Water sample temperature | 5~50℃ |
| Operating temperature | 5~45℃ |
| Operating humidity | ≤ 90% RH (non-condensing) |
| Display resolution | 0.1℃ |
| An indication of temperature error | 0.5℃ |
| Current Output | 0~10mA, 0~20mA, 4~ 20mA optional, load < 300Ω |
| Alarm relay | 2 normally open points can be set arbitrarily, AC 220V 3A/DC 30V 3A |
| output load Capacity | ≤750Ω |
| Output Accuracy | 1%F.S |
| Relay load Capacity | AC 250V 5A/DC 30V 5A |
| Power Supply | AC (85~ 265) V Frequency (45~ 65) Hz |
| Power | ≤ 15W |
| opening size | 138 mm×138 mm |
TIMEPOWER TP122 Conductivity analyzer Packing list
Host X1, acid/base concentration meter composite electrode X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveJJG 2059-2014
- ActiveGB/T 13580.3-1992
- ActiveGB/T 6539-1997
- ActiveGB/T 18932.15-2003
- ActiveGB/T 11007-2008
- ActiveGB/T 23977-2009
- ActiveGB/T 20245.3-2013
- ActiveGB/T 41079.2-2022
- ActiveGB/T 6908-2018
- ActiveGB/T 7977-2007
- ActiveGB/T 32697-2016
- ActiveGB/T 33328-2016
- ActiveISO 21318-2007
- ActiveISO 9944-1990
- ActiveGB/T 27503-2011
- ActiveGB/T 27502-2011
- ActiveJB/T 9366-1999
- ActiveJB/T 6855-1993
- ActiveASTM D 4399-90-2017
- AbolishHG/T 2-1047-1977


TIMEPOWER
TP122