Introduction
TP160 ORP analyzer is a high-precision intelligent instrument, with full Chinese display, Chinese menu operation, multi-function, high measurement performance, strong environmental adaptability, etc., can accurately measure the redox potential value and temperature of the solution.

Features
Using 128×64 dot matrix LCD module, all data, status and operation tips are Chinese display, easy to understand and easy to operate.
The instrument adopts high-precision A/D conversion and single-chip microcomputer microprocessor technology, with high performance and low power consumption.
The motherboard adopts SMD technology and highly integrated isolation circuit design, which has good anti-interference performance, stability and durability.
The standard output signal type is optional, and the alarm of the two sets of relay control switches can be set arbitrarily.
The data loop storage function automatically clears the overflow data, which is convenient to operate and simple to query.
IP65 protection level, suitable for outdoor use.
TIMEPOWER TP160 ORP AnalyzerSpecifications
| LIST | VALUE |
|---|---|
| Display | 128 * 64 dot matrix LCD, Chinese display |
| Measurement range | ±2000mV |
| An indication of electrical error | ±1 mV |
| Resolution | 0.1 mV |
| Temperature compensation range | 0~60℃ |
| Water sample temperature | 5~60℃ |
| water sample pressure | <0.6MPa |
| Environmental temperature | 5~45℃ |
| Working Relative Humidity | ≤ 90% RH (non-condensing) |
| Storage temperature | -25~55℃ |
| Power Supply | AC (85~ 265) V Frequency (45~ 65) Hz |
| power consumption | ≤15W |
| Dimensions | 145*120*150mm |
| opening size | 138*138mm |
| Weight | 0.64kg |
| Current Output | 0~10mA, 0~20mA, 4~ 20mA optional, load < 300Ω |
| Alarm relay | 2 normally open points can be set arbitrarily, AC220V 3A /DC30V 3A |
| Protection level | IP65 |
| Power down save | > 10 years |
TIMEPOWER TP160 ORP Analyzer Packing list
Host X1, ORP three composite electrode X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.


TIMEPOWER
TP160