TIMEPOWER TP352 dissolved oxygen analyzer, portable dissolved oxygen analyzer
TIMEPOWER-
HANNA HI981420 Water Quality Tester
$ 746.00 -
NOBOTECH NPT-PH106 Waterproof Pen ORP Detector
$ 126.00 -
HANNA HI7091L Oxidation-reduction potential calibrating solution (ORP) reduction pretreatment solution
$ 137.00 -
LEICI DJS-1C Conductivity Detector electrode
$ 95.00 -
HANNA HI97770 Silica/Silicon [HR] Portable Photometer
$ 613.00
Introduction
TP352 Micro Dissolved Oxygen Analyzer is an easy-to-use high-precision dissolved oxygen analyzer, with color touch screen, easy to operate and read, using original imported fluorescent sensor, long life, accurate measurement, can be widely used in power plants, chemical plants and other industries.

Features
High-precision imported fluorescence sensor, fast response speed and long life
No polarization, no correction in general, no stirring
There is no need to change the membrane, no electrolyte to change, no need to polish the anode
Not affected by traffic
Professional chip placement process and integrated design, highly integrated circuit design is stable and durable
Data cycle storage function, automatic removal of overflow data, simple operation, convenient query, power failure data storage time of more than 10 years
Long continuous use time, up to 8 hours of measurement on a full charge
The appearance is small and beautiful, and it is easy to carry
TIMEPOWER TP352 Dissolved oxygen analyzerSpecifications
| LIST | VALUE |
|---|---|
| Display | Touch color dot matrix LCD, Chinese display |
| Measurement range | 0.0~20000.0μg/L |
| Accuracy | +/- 1.5% FS or +/- 3 μg/L |
| Resolution | 0.1μg/L |
| Repeatability | ≤1% |
| Response time | T90<5min (25℃) |
| Temperature compensation range | 0~60℃ |
| Water sample temperature | 5~45℃ |
| Environmental temperature | 5~45℃ |
| Working Relative Humidity | ≤ 90% RH (non-condensing) |
| Power Supply | DC3.7V (lithium battery) |
| power consumption | ≤ 0.5W |
| Data storage | 256 articles |
| Charging time | ≥6h |
| Dimensions | 285*60*255mm |
| Weight | 2.28kg |
TIMEPOWER TP352 Dissolved oxygen analyzer Packing list
Host X1, dissolved oxygen electrode X1, fluorescent cap X1, flow pool X1, electrode mounting cover X1, rechargeable battery X1, external wire threaded pipe joint X1, electrode socket X1, power socket X1, adapter X1, suitcase X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveJJF 1714-2018
- ActiveJJF 1441-2013
- ActiveJJG 2104-2024
- AbolishGB/T 12157-2007
- ActiveGB/T 20245.4-2013
- ActiveGB/T 12157-2022
- ActiveHJ 2515-2012


TP352





![HANNA HI97770 Silica/Silicon [HR] Portable Photometer](http://img.nbchao.com/imgs/200/2024/03/28/1725050916848944.jpg)