LEICI DWS-51 sodium Ion Meter measurement pNa/Na + concentration value 0.00~9.00pNa
The LEICI DWS-51 sodium Ion Meter is dedicated to testing the pNa and Na + concentration values of aqueous solutions in CHINA. It is a desktop manual temperature compensation Ion Meter. The pNa resolution of the DWS-51 sodium Ion Meter measurement is 0.01 pNa, and it adopts a large-screen LCD liquid crystal display.
LeiCi-
Qiwei PXS-K potassium Ion meter
$ 370.00 -
BANTE ISE-K potassium ion selective electrode
$ 384.00 -
LEICI PNO3 -1-01 type nitrate ion electrode adapted to pH, Ion Meter BNC (Q13 type)
$ 121.00 -
BANTE S30-Ag Wireless Bluetooth Silver Ion Meter 0.0000001~ 1mol/L
$ 712.00 -
Potassium ion standard solution 1000ppm, 480ml
$ 131.00








Introduction
Different from DWS-295F, DWS-51 sodium ion can only measure pNa and Na+ concentration values, and the measured pNa resolution is 0.01, and the temperature is manually compensated to ensure that the temperature is within a reasonable range.DWS-51 sodium ions can be calibrated and measured statically and dynamically, and is suitable for detecting the concentration of Na+ ions in aqueous solutions in power plants, environmental protection, scientific research structures, ** and other fields.
Features
1. Large-screen LCD segment code LCD, clear and beautiful display;
2. DWS-51 sodium Ion Meter can measure pNa value and sodium ion concentration value [Na+];
3. Manual temperature compensation function, two-point calibration (static and dynamic calibration);
4. Static and dynamic measurement (optional DWS-51-1 alkalizing device can achieve dynamic measurement);
5. DWS-51 sodium Ion Meter not only has pNa value display, but also has sodium ion concentration value [Na+] display function;
6. Beautiful and lightweight appearance.
Actual picture of the product

LeiCi DWS-51 sodium Ion MeterSpecifications
| LIST | VALUE |
|---|---|
| Measurement parameters | PNa, Na + concentration value |
| Measurement range | (0.00~9.00)pNa;(2.3×10 -2~2.3×10 7)μg/L |
| Resolution | 0.01pNa |
| Intrinsic error | +/- 0.02pNa +/- 1 word |
| Stability | (+/- 0.02pNa +/- 1 word)/3h |
| Temperature compensation method | manual |
| calibration | Two-point calibration (static and dynamic calibration) |
| Measurement | Static and dynamic measurement |
| Display | LED |
| Power Supply | AC (220±22)V;(50±1)Hz |
| Dimensions | 290*210*95mm |
| Weight | 1.5kg |
| Calculation error of pNa value~ [Na +] value conversion | +/- 3% (reading) |
| Temperature compensation range | 0~60℃ |
LeiCi DWS-51 sodium Ion Meter Packing list
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- The Secrets of Metal Electrodeposition: From Molecular Motion to Industrial Applications
- Electrochemistry Corrosion and Its Influencing Factors
- Repair of PXD universal Ion meter
- Coating corrosion resistance inspection -- electrolysis corrosion test
- D10P-06 Desktop Sodium Ion Meter Manual
- Water quality, water treatment method and explanation of water treatment terms
- Ion meter measurement of fluorine content in soil
- Centennial history of ion selective electrode and Ion meter
- Analysis on the technology and maintenance of medical pure water equipment
- Ion meter error indication of uncertainty in mathematical model


DWS-51