Search
    Cart(0)
      总价
      前往结算
      您的购物车是空的 : )
      Home> Coating Thickness Gauge> BoTech> BoTech BCT-210A Coating Thickness Gauge

      BOTECH botech BCT-210A split Coating Thickness Gauge

      BOTECH botech BCT-210A split Coating Thickness Gauge is suitable for film thickness measurement of paints, enamel layers, aluminum tiles, copper tiles, Babbitt tiles, phosphating layers, paper, and can also be used for film thickness measurement of hull paints and attachments of underwater structures.

      Brand
      SKU: NB017126
      China BoTech
      VS
      BoTechLOGO

      BoTech

      Information
      Genuinegoods
      • BoTech BCT-210A Coating Thickness GaugeOverview

      • Specifications
      • Comments
      • FAQs
      BCT-210A
      Coating Thickness Gauge

      Overview

      BCT-210A is a high-precision coating Thickness Gauge independently developed by Pertai, as a portable measuring instrument, it can quickly, non-damage, precision coating and coating thickness measurement, with high measurement accuracy, wide measurement range, fast measurement speed and other advantages. It can be used both in the laboratory and in the engineering field. By using different probes, a wide range of measurement needs can also be met. This instrument can be widely used in manufacturing, metal processing industry, chemical industry, commodity inspection and other testing fields. It is an instrument required for the material protection profession.

      Features

      Two thickness measurement methods, magnetic and eddy current, can measure the thickness of the non-magnetic overburden on the magnetic metal substrate and the thickness of the non-conductive overburden on the non-magnetic metal substrate

      10 probes available (F400, F1, F1/90°, F5, F10, N400, N1, N1/90°, CN02, N10)

      There are two measurement methods: continuous measurement method (CONTINUE) and single measurement method (SINGLE)

      It has two Operating Modes: direct mode (DIRECT) and group mode (A-B)

      There are five statistics: mean (MEAN), maximum (MAX), minimum (MIN), number of tests (NO.), standard deviation (S.DEV)

      The instrument can be calibrated using both single-point calibration and two-point calibration, and the systematic error of the probe can be corrected using the basic calibration method

      Direct measurement status: 120 measured values can be measured

      With storage function: 600 measured values can be stored

      It has a delete function: it can delete a single suspicious data that appears in the measurement, and it can also delete all the data in the storage area so that a new measurement can be made

      Limits can be set: automatic alarms can be given for measured values outside the limits

      It has the function of power supply under-Voltage indication

      It has an error prompt function, which can be used to prompt errors through screen display or beep

      There are two shutdown modes: manual shutdown mode and automatic shutdown mode

      The probe contact parts are hard chrome or ruby plated for durability

      It can be equipped with microcomputer software, which has rich functions such as transmitting measurement results, measuring value storage management, statistical analysis of measured values, and printing measurement reports

      Small, portable, rugged and durable in plastic housing, it is suitable for harsh operating environments

      Main uses:

      It can be applied to the thickness measurement of electroplating layer, paint layer, enamel layer, aluminum tile, copper tile, babbitt tile, phosphating layer, paper

      Thickness measurement of hull paint and attachments to underwater structures

      This instrument can be widely used in manufacturing, metal processing industry, chemical industry, commodity inspection and other testing fields

      Operating Conditions

      Ambient temperature: operating temperature -10°C~+40°C

      Storage temperature: -30°C~+70°C

      Relative Humidity≤90%

      There is no strong vibration, no strong magnetic field, no corrosive medium and no serious dust in the surrounding environment

      Product mockups



      VS

      BoTech BCT-210A Coating Thickness GaugeSpecifications

      LIST VALUE
      measurement principle Magnetic Induction + eddy Current
      Measurement Range 0~1250μm
      margin of error ±2%
      resolution 0.1μm
      Calibrated mode Single point calibrated and two point calibrated
      statistical function Single measurement, continuous measurement
      Unit display μm/mils
      statistical function Measurement times, MAX Maximum, MIN Minimum, Average, Standard deviation
      Data Interface USB communication interface, can connect and communicate with PC
      data storage Can store 600 measurements
      Power Supply 3V (2 AA alkaline batteries)
      Display screen 128 * 64 dot matrix liquid crystal LCD
      operating temperature -10~40℃
      Relative Humidity ≤90%RH
      operating temperature The surrounding environment has no strong vibration, no strong magnetic field, no corrosive medium and serious dust
      battery life More than 200h (when the backlight is not turned on)
      Weight 400g
      Dimensions 125*67*31mm

      BoTech BCT-210A Coating Thickness Gauge Packing list

      [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

      FAQ

      [Q]
      Is there an ISO2360 standard Coating thickness gauge?
      [A]
      This BOTECH Coating thickness gauge is ok!
      BoTech
      BOTECH botech BCT-210A split Coating Thickness Gauge
      Service
      Focus on online sales of Lab Testing Instruments