BOTECH botech BCT-200B high accuracy split Coating Thickness Gauge
BCT-200B high accuracy split Coating Thickness Gauge adopts magnetic and eddy current thickness measurement methods, which can quickly, nondestructive and precise measurement of coating and platings Film thickness. It can be used in laboratories or engineering sites.
BoTech-
Germany Nix QNix 4500 + FN5 integrated dual-use coating platings Thickness Gauge FeNFe dual-use probe 0-5000μm
$ 1345.00 -
German EPK MiniTest 600 B-N eddy current platings Thickness Gauge, thickness: 0~2000μm
$ 952.00 -
Germany Nix QNix 4500 + FN3 integrated dual-use coating platings Thickness Gauge FeNFe dual-use probe 0-3000μm
$ 957.00 -
Defelsko PosiTector 6000 F1 Coating Thickness Gauge Iron metal substrate nonmagnetic coating
$ 845.00 -
LINSHANG LS237 Film Thickness Gauge (for automobile paint thickness detection)
$ 173.00
Overview
BCT-200B is a high-end coating Thickness Gauge independently developed by Petai, as a portable measuring instrument, it can quickly, non-damage, precise measurement of coating and coating thickness, it has the advantages of wide measurement range, fast measurement speed and high measurement accuracy. It can be used both in the laboratory and in the engineering field. By using different probes, a wide range of measurement needs can also be met. This instrument can be widely used in manufacturing, metal processing industry, chemical industry, commodity inspection and other testing fields. It is an instrument required for the material protection profession.

Features
Two thickness measurement methods, magnetic and eddy current, are used to measure the thickness of the non-magnetic overlay on the magnetic metal substrate and the thickness of the non-conductive overlay on the non-magnetic metal matrix
10 probes available (F400, F1, F1/90°, F5, F10, N400, N1, N1/90°, CN02, N10)
There are two measurement methods: continuous measurement method (CONTINUE) and single measurement method (SINGLE)
It has two Operating Modes: direct mode (DIRECT) and group mode (A-B)
There are five statistics: mean (MEAN), maximum (MAX), minimum (MIN), number of tests (NO.), standard deviation (S.DEV)
The instrument can be calibrated using both zero and two-point calibration, and the systematic error of the probe can be corrected using the basic calibration method
Storage: 495 measured values can be stored
It has a delete function: it can delete a single suspicious data that appears in the measurement, and it can also delete all the data in the storage area so that a new measurement can be made
Limits can be set: automatic alarms can be given for measured values outside the limits
It has the function of power supply under-Voltage indication
It has an error prompt function, which can be used to prompt errors through screen display or beep
There are two shutdown modes: manual shutdown mode and automatic shutdown mode
The probe contact parts are hard chrome or ruby plated for durability
It can be equipped with microcomputer software, which has rich functions such as transmitting measurement results, measuring value storage management, statistical analysis of measured values, and printing measurement reports
Small, portable, rugged and durable in an aluminum enclosure, it is suitable for harsh operating environments and is resistant to vibration, shock and electromagnetic interference
Main uses:
It can be applied to the thickness measurement of electroplating layer, paint layer, enamel layer, aluminum tile, copper tile, babbitt tile, phosphate layer paper
Thickness measurement of hull paint and attachments to underwater structures
It is widely used in manufacturing, metal processing industry, chemical industry, commodity inspection and other testing fields
Operating Conditions
Ambient temperature: operating temperature -20°C~+50°C
Storage temperature: -30°C~+70°C
Relative Humidity≤90%
There is no strong vibration, no strong magnetic field, no corrosive medium and no serious dust in the surrounding environment
BoTech BCT-200B Coating Thickness GaugeSpecifications
| LIST | VALUE |
|---|---|
| measurement principle | Magnetic Induction + eddy Current |
| Measurement Range | 0~1250μm |
| margin of error | ±2% |
| resolution | 0.1μm |
| Calibrated mode | Single point calibrated and two point calibrated |
| statistical function | Single measurement, continuous measurement |
| Unit display | μm/mils |
| statistical function | Measurement times, MAX Maximum, MIN Minimum, Average, Standard deviation |
| Data Interface | USB communication interface, can connect and communicate with PC |
| data storage | Can store 5 sets (up to 100 measurements each) measurement data |
| Power Supply | 3V (2 AA alkaline batteries) |
| Display screen | 128 * 64 dot matrix liquid crystal LCD |
| operating temperature | -20~50℃ |
| Relative Humidity | ≤90%RH |
| operating temperature | The surrounding environment has no strong vibration, no strong magnetic field, no corrosive medium and serious dust |
| battery life | More than 200h (when the backlight is not turned on) |
| Weight | 340g |
| Dimensions | 115*67*31mm |
BoTech BCT-200B Coating Thickness Gauge Packing list
machine X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Which Coating Thickness Gauge is Right for You?
- How is the surface profile of precast concrete measured?
- Application of Coating Thickness Gauge on Galvanized Steel Sheet
- Analysis of Thickness Measurement Method for Coating Thickness Measurement
- Two Methods of Coated Film thickness measurement
- Why Use Coating Thickness Gauges in Powder Coatings?
- ActiveQJ 990.3A-2011
- ActiveASTM B244-2021
- ActiveISO 2360-2017
- ActiveISO 2178-2016
- ActiveASTM D7091-2022
- ActiveASTM B499-2021
- ActiveISO 19840-2012
- ActiveGB/T 1740-2007
- ASTM E376-2019
- ActiveISO 2808-2019
- AbolishJJG 889-1995
- AbolishJJG 818-1993
- ActiveGB/T 4956-2003
- ISO 2361-1982
- ActiveHG/T 3885-2006
- ActiveGB/T 6463-2005
- AbolishGB/T 4956-1985
- AbolishASTM G12-07-2013
- AbolishISO 2808-2007
- ActiveJB/T 5000.12-2007


BCT-200B





