Yuefeng SGZ-400B Portable Turbidity Meter 0~400NTU/0.01
Yuefeng instrument SGZ-400B portable Turbidity Meter measurement principle 90 ° scattered light, measuring range 0~400NTU, indication accuracy 0.01, indication stability ± 1.5% (F. S 30min), zero drift ± 1.5% (F. S 30min), sexual repeability 1% F. S, error of indication ± 6%.
YUEFENG-
HANNA HI88713 Microcomputer multi-range Turbidimeter (ISO standard)
$ 3124.00 -
HANNA HI83414 Benchtop residual chlorine - total chlorine - turbidity Tester (EPA standard)
$ 3250.00 -
YueFeng SGZ-50BJ Beer Turbidity Meter 0~50EBC
$ 487.00 -
Yuefeng SGZ-50A interface Turbidity Meter with printing interface
$ 316.00 -
Qiwei WGZ-1B Precision Portable Turbidity Meter 0~200NTU
$ 181.00
Features
LCD LCD display with backlight, making reading more comfortable and not affected by natural light.
The operation is simple, the measurement range is appropriate, and the price is high.
The unique positioning structure and high-precision optical path system can effectively ensure the accuracy and repeatability of the measured value.
The circuit system with low drift, high precision and good stability, and the effective and long-life light source can effectively ensure the stable operation of the instrument for a long time.
The instrument can be powered by AC or DC, low power consumption configuration, small and light design, easy to use in the field or in the laboratory.
The low-Voltage indication function instructs the user to replace the battery in time to ensure accurate and effective measurement values.

YUEFENG SGZ-400B Turbidity MeterSpecifications
| LIST | VALUE |
|---|---|
| Measurement principle | 90 ° scattered light |
| Measuring range | 0 ~ 400NTU |
| resolution | 0.01 |
| Indication stability | ±1.5%(F.S 30min) |
| Zero drift | ±1.5%(F.S 30min) |
| Sexual repeability | ±1%F.S |
| Error of indication | ±6% |
YUEFENG SGZ-400B Turbidity Meter Packing list
complete-built unit X1, manual X1, certificate of conformity X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- 10 Tips for Using Turbidity Meters Correctly and Keeping Accurate Measurements
- Turbidity Meter/Turbidity Sensor FAQ
- How to verify the photoelectric Turbidimeter?
- Photoelectric Turbidity Meters for Varnish Transparency Testing
- How to measure the turbidity of a liquid?
- Why is silicone oil important in turbidity meter measurements?
- ActiveJIS K0801-1986
- ActiveJJF 1700-2018
- ActiveJJF 1571-2016
- Active 100-2007
- ActiveDIN EN ISO 15715-2006
- ActiveGB/T 13531.3-1995
- ActiveGB/T 13200-1991
- ActiveHJ 1075-2019
- ActiveHJ 1075-2019
- ActiveGB/T 18570-2009
- ISO 15715-2003


SGZ-400B