Yuefeng SGZ-1000BS Portable Turbidity Meter 0~1000NTU/0.1
Measuring range 0~400NTU, 400~1000NTU, resolution 0.1, indication stability ± 1.5% (F. S 30min), zero drift ± 1.5% (F. S 30min), sexual repeability 1.5% F. S, error of indication ± 6%.
YUEFENG-
Qiwei WGZ-1000AS Microcomputer Turbidity Meter 0~1000NTU
$ 324.00 -
INESA INESA WGZ-1000 desktop Turbidity Meter 1000NTU
$ 863.00 -
HANNA HI83749 Liquor turbidity and silica soda Tester
$ 1743.00 -
Yuefeng SGZ-400B Portable Turbidity Meter 0~400NTU/0.01
$ 381.00 -
Qiwei WGZ-500AS Microcomputer Turbidity Meter 0~500NTU
$ 257.00
Features
LCD LCD display with backlight, making reading more comfortable and not affected by natural light.
The operation is simple, the measurement range is appropriate, and the price is high.
The unique positioning structure and high-precision optical path system can effectively ensure the accuracy and repeatability of the measured value.
The circuit system with low drift, high precision and good stability, and the effective and long-life light source can effectively ensure the stable operation of the instrument for a long time.
The instrument can be powered by AC or DC, low power consumption configuration, small and light design, easy to use in the field or in the laboratory.
The low-Voltage indication function instructs the user to replace the battery in time to ensure accurate and effective measurement values.

YUEFENG SGZ-1000BS Turbidity MeterSpecifications
| LIST | VALUE |
|---|---|
| Measurement principle | 90 ° scattered light |
| Measuring range | 0~400NTU、400~1000NTU |
| resolution | 0.1 |
| Indication stability | ±1.5%(F.S 30min) |
| Zero drift | ±1.5%(F.S 30min) |
| Sexual repeability | ±1.5%F.S |
| Error of indication | ±6% |
YUEFENG SGZ-1000BS Turbidity Meter Packing list
complete-built unit X1, manual X1, certificate of conformity X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- How to measure the turbidity of a liquid?
- 10 Tips for Using Turbidity Meters Correctly and Keeping Accurate Measurements
- Turbidity Meter/Turbidity Sensor FAQ
- Why is silicone oil important in turbidity meter measurements?
- How to verify the photoelectric Turbidimeter?
- ActiveJIS K0801-1986
- ActiveJJF 1700-2018
- ActiveJJF 1571-2016
- Active 100-2007
- ActiveDIN EN ISO 15715-2006
- ActiveGB/T 13531.3-1995
- ActiveGB/T 13200-1991
- ActiveHJ 1075-2019
- ActiveHJ 1075-2019
- ActiveGB/T 18570-2009
- ISO 15715-2003


SGZ-1000BS