Yuefeng SGZ-800I Microcomputer Turbidity Meter 800NTU/0.01
SGZ-800I microcomputer Turbidity Meter measuring range 0~800NTU, resolution 0.01, zero drift ± 1.5% (F. S 30min), indication stability ± 1.5% (F. S 30min), sexual repeability ≤ 2%, error of indication ± 6%.
YUEFENG-
HANNA HI83414 Benchtop residual chlorine - total chlorine - turbidity Tester (EPA standard)
$ 3250.00 -
INESA INESA WGZ-1000B Portable Turbidity Meter 1000NTU
$ 654.00 -
Yuefeng SGZ-800IT Microcomputer Turbidity Meter 800NTU/0.001
$ 599.00 -
LEICI WZT-701 Online turbidity monitor
$ 2681.00 -
LEICI WZB-170 Turbidity Meter 850nm/200NTU
$ 483.00
Features
Streamlined exterior design.
Adopt blue screen liquid crystal display module, menu display mode, humanized operation.
Simple operation, wide range of light measurement and high cost performance are more suitable for use in various industries.
The unique positioning structure and high-precision optical path system effectively ensure the stable operation of the instrument for a long time.
According to different ranges, multi-point calibration is adopted to meet the needs of different users.
The built-in printer is convenient for users to print in real time.
The chromaticity compensation system is added to effectively avoid the interference caused by the color of the sample, and can correctly reflect the concept of turbidity.

Models
| Product number | Measuring range (NTU) | Minimum indication | zero drift | Indication stability | repeatability | Indication error |
| (F.S30min) | (F.S30min) | (linear error) | (basic error) | |||
| SGZ-200I | 0~20,20~200 | 0.01 | ±1.5% | ±1.5% | ≤2% | ±6% |
| SGZ-200IT | 0~20,20~200 | 0.001 | ±1.5% | ±1.5% | ≤2% | ±6% |
| SGZ-500I | 0~20,20~200,200~500 | 0.01 | ±1.5% | ±1.5% | ≤2% | ±6% |
| SGZ-500IT | 0~20,20~200,200~500 | 0.001 | ±1.5% | ±1.5% | ≤2% | ±6% |
| SGZ-800I | 0~20,20~200,200~500,500~800 | 0.01 | ±1.5% | ±1.5% | ≤2% | ±6% |
| SGZ-800IT | 0~20,20~200,200~500,500~800 | 0.001 | ±1.5% | ±1.5% | ≤2% | ±6% |
| SGZ-1000I | 0~20,20~200,200~500,500~1000 | 0.01 | ±1.5% | ±1.5% | ≤2% | ±6% |
| SGZ-1000IT | 0~20,20~200,200~500,500~1000 | 0.001 | ±1.5% | ±1.5% | ≤2% | ±6% |
| SGZ-2000I | 0~20,20~200,200~500,500~1000,1000~1500,1500~2000 | 0.01 | ±1.5% | ±1.5% | ≤2% | ±6% |
| SGZ-2000IT | 0~20,20~200,200~500,500~1000,1000~1500,1500~2000 | 0.001 | ±1.5% | ±1.5% | ≤2% | ±6% |
| SGZ-4000I | 0~20,20~200,200~500,500~1000,1000~1500,1500~2000,2000~4000 | 0.01 | ±1.5% | ±1.5% | ≤2% | ±6% |
| SGZ-4000IT | 0~20,20~200,200~500,500~1000,1000~1500,1500~2000,2000~4000 | 0.001 | ±1.5% | ±1.5% | ≤2% | ±6% |
YUEFENG SGZ-800I Turbidity MeterSpecifications
| LIST | VALUE |
|---|---|
| Measuring range | 0~20NTU、20~200NTU、200~500NTU、500~800NTU |
| resolution | 0.01 |
| Zero drift | ±1.5%(F.S 30min) |
| Indication stability | ±1.5%(F.S 30min) |
| Sexual repeability | ±2%F.S |
| Error of indication | ±6% |
YUEFENG SGZ-800I Turbidity Meter Packing list
complete-built unit X1, manual X1, certificate of conformity X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- 10 Tips for Using Turbidity Meters Correctly and Keeping Accurate Measurements
- Turbidity Meter/Turbidity Sensor FAQ
- How to measure the turbidity of a liquid?
- Techniques for measuring turbidity in water
- How to verify the photoelectric Turbidimeter?
- A brief analysis of the principle, theory and technology of turbidity method and turbidity method
- Why is silicone oil important in turbidity meter measurements?
- ActiveJIS K0801-1986
- ActiveJJF 1700-2018
- ActiveJJF 1571-2016
- Active 100-2007
- ActiveDIN EN ISO 15715-2006
- ActiveGB/T 13531.3-1995
- ActiveGB/T 13200-1991
- ActiveHJ 1075-2019
- ActiveHJ 1075-2019
- ActiveGB/T 18570-2009
- ISO 15715-2003