Yuefeng SGZ-4000IT Microcomputer Turbidity Meter 4000NTU/0.001
SGZ-4000IT microcomputer Turbidity Meter measuring range 0~20NTU, 204000NTU, resolution 0.001, zero drift ± 1.5% (F. S 30min), indication stability ± 1.5% (F. S 30min), sexual repeability ≤ 2%, error of indication ± 6%.
YUEFENG-
JINGQI WGZ-1000 Precision turbidity instrument 1000NTU +/- 2%
$ 640.00 -
JINGQI WGZ-400BJ Portable precision low turbidity instrument
$ 613.00 -
YueFeng SGZ-6AXJ Portable Bacterial Turbidity Meter 0~6.000MCF
$ 739.00 -
Qiwei WGZ-200 Precision Benchtop Dual Range Turbidity Meter 0-20NTU/0-200NTU
$ 225.00 -
BANTE TB200 laboratory Turbidity Meter
$ 706.00
Features
Streamlined exterior design.
Adopt blue screen liquid crystal display module, menu display mode, humanized operation.
Simple operation, wide range of light measurement and high cost performance are more suitable for use in various industries.
The unique positioning structure and high-precision optical path system effectively ensure the stable operation of the instrument for a long time.
According to different ranges, multi-point calibration is adopted to meet the needs of different users.
The built-in printer is convenient for users to print in real time.
The chromaticity compensation system is added to effectively avoid the interference caused by the color of the sample, and can correctly reflect the concept of turbidity.

Models
| Product number | Measuring range (NTU) | Minimum indication | zero drift | Indication stability | repeatability | Indication error |
| (F.S30min) | (F.S30min) | (linear error) | (basic error) | |||
| SGZ-200I | 0~20,20~200 | 0.01 | ±1.5% | ±1.5% | ≤2% | ±6% |
| SGZ-200IT | 0~20,20~200 | 0.001 | ±1.5% | ±1.5% | ≤2% | ±6% |
| SGZ-500I | 0~20,20~200,200~500 | 0.01 | ±1.5% | ±1.5% | ≤2% | ±6% |
| SGZ-500IT | 0~20,20~200,200~500 | 0.001 | ±1.5% | ±1.5% | ≤2% | ±6% |
| SGZ-800I | 0~20,20~200,200~500,500~800 | 0.01 | ±1.5% | ±1.5% | ≤2% | ±6% |
| SGZ-800IT | 0~20,20~200,200~500,500~800 | 0.001 | ±1.5% | ±1.5% | ≤2% | ±6% |
| SGZ-1000I | 0~20,20~200,200~500,500~1000 | 0.01 | ±1.5% | ±1.5% | ≤2% | ±6% |
| SGZ-1000IT | 0~20,20~200,200~500,500~1000 | 0.001 | ±1.5% | ±1.5% | ≤2% | ±6% |
| SGZ-2000I | 0~20,20~200,200~500,500~1000,1000~1500,1500~2000 | 0.01 | ±1.5% | ±1.5% | ≤2% | ±6% |
| SGZ-2000IT | 0~20,20~200,200~500,500~1000,1000~1500,1500~2000 | 0.001 | ±1.5% | ±1.5% | ≤2% | ±6% |
| SGZ-4000I | 0~20,20~200,200~500,500~1000,1000~1500,1500~2000,2000~4000 | 0.01 | ±1.5% | ±1.5% | ≤2% | ±6% |
| SGZ-4000IT | 0~20,20~200,200~500,500~1000,1000~1500,1500~2000,2000~4000 | 0.001 | ±1.5% | ±1.5% | ≤2% | ±6% |
YUEFENG SGZ-4000IT Turbidity MeterSpecifications
| LIST | VALUE |
|---|---|
| Measuring range | 0~20NTU、20~200NTU、200~500NTU、500~1000NTU、1000~1500NTU、1500~2000NTU、2000~4000NTU |
| resolution | 0.001 |
| Zero drift | ±1.5%(F.S 30min) |
| Indication stability | ±1.5%(F.S 30min) |
| Sexual repeability | ±2%F.S |
| Error of indication | ±6% |
YUEFENG SGZ-4000IT Turbidity Meter Packing list
complete-built unit X1, manual X1, certificate of conformity X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- 10 Tips for Using Turbidity Meters Correctly and Keeping Accurate Measurements
- Techniques for measuring turbidity in water
- How to measure the turbidity of a liquid?
- How to verify the photoelectric Turbidimeter?
- What is a turbidity meter and how does it work?
- Why is silicone oil important in turbidity meter measurements?
- A brief analysis of the principle, theory and technology of turbidity method and turbidity method
- ActiveJIS K0801-1986
- ActiveJJF 1700-2018
- ActiveJJF 1571-2016
- Active 100-2007
- ActiveDIN EN ISO 15715-2006
- ActiveGB/T 13531.3-1995
- ActiveGB/T 13200-1991
- ActiveHJ 1075-2019
- ActiveHJ 1075-2019
- ActiveGB/T 18570-2009
- ISO 15715-2003


SGZ-4000IT