Kedian MC-3000B Coating Thickness Gauge built-in probe
MC-3000B Coating Thickness Gauge is an integrated structure Thickness Gauge, built-in magnetic probe, Kedian MC-3000B has temperature compensation and screen flip function, V-groove design makes the MC-3000B Coating Thickness Gauge convenient for measurement of various sizes of pipe outer surface coatings.
KODIN-
Leeb222 (N1) eddy current Thickness Gauge for non-magnetic metal substrates
Login -
LEEB260 high-precision Coating Thickness Gauge magnetic Induction
Login -
Defelsko NS conventional strip line probe measurement non-ferrous metal substrate coatings
$ 770.00 -
Defelsko PosiTector 6000 FRS1 import Thickness Gauge paints/film/film thickness measurement
$ 1024.00 -
Germany EPK MikroTest S20 McCourt enamel layer Thickness Gauge, thickness measurement: 7.5~ 20mm
$ 2675.00
Introducing the MC-3000B Coating Thickness Gauge
The MC-3000B is an all-in-one coating Thickness Gauge that can measure coating and coating thickness quickly, without damage, and accurately. It can be used both in the laboratory and in the engineering field. By using different probes, a wide range of measurement needs can also be met. This instrument can be widely used in manufacturing, metal processing industry, chemical industry, commodity inspection and other testing fields. It is an instrument required for the material protection profession. This instrument complies with the following standards: GB/T 4956─1985 Measurement of the thickness of non-magnetic overlay on magnetic metal substrates Magnetic method GB/T 4957─1985 Measurement of thickness of non-conductive overlay on non-magnetic metal substrate Eddy current method JB/T 8393─1996 Magnetic and eddy current cladding Thickness Gauge JJG 889─95 "Magnetoresistive Thickness Gauge" JJG 818─93 "Eddy current Thickness Gauge".
Features
●Two thickness measurement methods, magnetic and eddy current, can non-destructively measure the thickness of the non-magnetic cladding (such as zinc, aluminum, chromium, copper, rubber, paint, etc.) on the magnetic metal matrix (such as steel, iron, alloy and hard magnetic steel, etc.) and the thickness of the non-conductive cladding (such as rubber, paint, plastic, anodized film, etc.) on the non-magnetic metal matrix (such as copper, aluminum, zinc, tin, etc.).
●6 types of probes (F0.5, F1.2, F3, F5, F9, N1.2) can be used
●With temperature compensation function: equipped with Kedian's new "phase-locked loop" technology
●With screen flip function: You can manually choose to flip the measurement data to display
● Display: 2.4-inch TFT high-definition color screen, 320*240 pixels, large digital display
●Measurement speed: According to different applications, customers can choose two kinds of measurement speeds: single measurement and continuous measurement
●The instrument can be calibrated in three ways, and the systematic error of the probe can be corrected by the basic calibration method
●With storage function: more than 10,000 measurement points can be stored
● With delete function: you can delete one suspicious data in the storage group, and you can also delete all the stored data so that new measurements can be made
●Set the limit: The measured value outside the limit can be automatically alarmed
●Display language: built-in Chinese, English
●Unit of measurement: Metric, Imperial convertible
● With wireless communication function: Bluetooth 2.0, it can communicate wirelessly with computers and printers
●It has the function of power supply under-Voltage indication
●There is a beep prompt during operation
●There are two shutdown modes: manual shutdown mode and automatic shutdown mode
●V-groove: The humanized V-groove structure is convenient for measuring the coating on the outer surface of pipes of various sizes
●Large flat bottom: The special large flat bottom probe structure makes the instrument measurement more stable and repeatable
●Anti-slip mat: The professionally designed anti-slip mat with the anti-slip texture on the back of the chassis makes it easy for customers to get tired for a long time, which reflects the consistent concept of customer first
Pictures
KODIN MC-3000B Coating Thickness GaugeSpecifications
| LIST | VALUE |
|---|---|
| Measurement principle | Magnetic Induction + eddy Current |
| Measurement range | F0.5:0~0.5mm;F1.2:0~1.25mm;F3:0~3mm;F5:0~5mm;F9:0~9mm;N1.2:0~1.25mm |
| margin of error | ±3% |
| Resolution | 0.1μm|1μm|0.01mm |
| Minimum measurement surface | F0.5:6mm;F1.2:9mm;F3:12mm;F5:20mm;F9:20mm;N1.2:9mm |
| probe | Integrated probe |
| Power Supply | 2 * AA battery |
| Standards | GB/T 4956-1985、GB/T 4957-1985、JB/T 8393-1996、JJG 889-95、JJG 818-93 |
| system language | Chinese, English |
| Display screen | 2.4 inch TFT high definition color screen, 320 * 240 pixels, large digital display |
| Machine Weight | 220G (including battery) |
| Machine size | 150*68*33mm |
| statistical function | Lite mode, Monitoring mode, Statistics mode, MIN Minimum capture |
| Data storage | 10,000 Measured values |
KODIN MC-3000B Coating Thickness Gauge Packing list
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.


MC-3000B