PHS-3E laboratory acidity meter pH/mV (ORP)/temperature value
YueFeng PHS-3E laboratory acidity meter measurement parameters pH, mV, temperature, pH measuring range -2~ 18.0pH, resolution 0.01pH, temperature measuring range automatic/manual, 0.0~99.9 ℃
-
FANGZHOU FZ-660 2-in-1 electrode for organic sample measurement
$ 195.00 -
KODIDA CT-6821 Industrial pHmeter ORP
$ 127.00 -
FANGZHOU FZ-861 PH Glass electrode electrolysis solution, Eletroplating solution, chemical reagent PH test
$ 254.00 -
YUEPING PHS-3CU acidity meter Measurement range (-2.00~19.99) pH temperature (0.0~80.0) ℃
$ 228.00 -
BANTE E203-BNC universal pH electrode built-in temperature sensor for outdoor applications
$ 102.00
Introduction
YueFengs PHS-3E LABOratory pH Meter has a measurement range of -2~18.0 pH, a resolution of 0.01pH, and the instrument can also measure mV(ORP), temperature value, and the range of mV(ORP) and temperature value Respectively -1999~1999mV, 0.0~99.9°C, PHS-3E laboratory acidity meter is a laboratory instrument with LCD display function.

YUEFENG PHS-3E Laboratory acidity meterSpecifications
| LIST | VALUE |
|---|---|
| Measurement parameters | pH, mV, temperature |
| PH range | -2~18.0pH |
| resolution | 0.01pH |
| Temperature Measurement range | Automatic/manual, 0.0~99.9 ℃ |
| Stability (zero drift) | (0.01pH ± 1 word)/3h |
| input impedance | ≥ 1 × 10 ^ 12O |
| Instrument level | Level 0.01 |
| mV range | -1999~1999mV |
| Temperature Measurement range | 0.0~99.9℃ |
| mV resolution | 0.1°C |
| temperature resolution | 0.1℃ |
| pH intrinsic error | ± 0.01pH ± 1 word |
| mV measurement Accuracy | ±0.1%F.S |
| Temperature intrinsic error | ± 0.3 ℃ ± 1 word |
| calibration | Two-point calibration |
| Buffer recognition | Automatic identification of 3 standard buffer solutions: 4.00pH, 6.86pH, 9.18pH |
| Measured solution temperature | 5~60°C |
| Display | LCD |
YUEFENG PHS-3E Laboratory acidity meter Packing list
complete-built unit X1, manual X1, certificate of conformity X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Experimental operation steps of pH meter
- What is ORP in solution testing?
- Detailed steps for pH determination of solutions
- What factors affect ORP measurements?
- ActiveGB/T 3324-2024
- ActiveGB/T 44332-2024
- ActiveGB/T 2394-2024
- ActiveJJF 1575-2016
- ActiveJJG 2060-2014
- ActiveJJF 919-2023
- ActiveHG/T 2797.4-2007
- ActiveSN/T 1523-2005
- ActiveQB/T 2724-2018
- ActiveJB/T 6203-2017
- ActiveNY/T 82.7-1988
- ActiveGB/T 1601-2023
- ActiveGB/T 6920-1986
- ActiveGB/T 13580.4-1992
- AbolishGB/T 1601-1993
- ActiveGB/T 9724-2007
- ActiveGB/T 22592-2008
- ActiveGB/T 12010.4-2010
- ActiveGB/T 2390-2013
- ActiveGB/T 3780.7-2016


YUEFENG
PHS-3E
PHS-3D
PHS-3B
PHS-3C