YUEFENG 723S (PC) visible spectrophotometer 325nm~ 1100nm
Wavelength 325~ 1100nm, Bandwidth 2nm, Stray ≤ 0.05% T, drift 0.001A/h, LCD, Sample chamber 5~ 100mm, C-T optical path, USB, Automatic calibration
YUEFENG-
Shanghai JINGHUA 7600SCRT Dual beam of light UV-Visible Spectrophotometer Standard computer/printer
$ 5906.00 -
JINGHUA 5cm Colorimetric dish, width 5cm
$ 114.00 -
Shanghai JINGHUA 7600-I Dual beam of light UV-Visible Spectrophotometer Deuterium lamp/tungsten lamp light source
$ 4934.00 -
JINGHUA 7600 Dual beam of light UV-Visible Spectrophotometer Wavelength Accuracy : ± 0.5nm
$ 4610.00 -
Shanghai JINGHUA 7600S Dual beam of light UV-Visible Spectrophotometer wavelength accuracy +/- 0.3nm
$ 5258.00
Features
Large-screen LCD (64×128) graphic liquid crystal display.
The spacious sample room can accommodate 5 ~ 100mm cuvette.
The host can perform photometric detection, quantitative detection, and can display standard curves, and can store 100 standard curves and 200 detection data.
With wavelength automatic calibration, automatic power off to keep data.
The main components adopt imported configuration, which is convenient for maintenance.
The newly designed Czerny-Turner optical path ensures the accuracy of detection linearity and ultra-low stray light.
Can be directly connected to a printer (optional) to print data or maps.

Main functions of the instrument
Photometry
The test of absorbance, transmittance and concentration at a fixed wavelength.
quantitative test
a. Standard curve method: Up to nine standard curves can be established, and the graph and regression equation can be displayed.
b. Coefficient method: use the formula C=KA+B, A=KC+B, and pass the input correlation coefficient test.
System functions
Wavelength calibration, dark current calibration...
YUEFENG 723S(PC) Visible spectrophotometerSpecifications
| LIST | VALUE |
|---|---|
| Optical inspection system | Aberration Elimination (1200L/mm Grating) |
| Light spectrum bandwidth | 2nm |
| Wavelength range | 325~1100nm |
| Wavelength Accuracy | ±0.5nm |
| Wavelength Repeatability | ≤0.3nm |
| Photometric range | 0~200%T、-0.301~3.000A、0~9999C |
| Photometric Accuracy | ±0.002A(0~0.5A)、±0.003A(0.5~1A)、±0.5%T |
| Luminosity, sexual repeability | ≤0.2%T(0~100%T);0.001A(0~0.5A);0.002A(0.5~1A) |
| stray light | ≤0.05%T@360nm |
| Noise level | 100%≤0.15%T;0%≤0.1%T |
| Baseline flatness | ±0.002A |
| Data Interface | USB interface and PC software |
| printout | Parallel port |
| light source | Tungsten Halogen Lamp |
| Dimensions | 450*340*180mm |
| Weight | 13kg |
| Drift | ≤0.001A/h@500nm |
| Scanning speed | Fast, medium, slow |
YUEFENG 723S(PC) Visible spectrophotometer Packing list
host X1, software X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Application of Spectrophotometer in Quantitative Analysis of Chemicals
- Application of Spectrophotometer in Spectral Reflectance
- How does a Spectrophotometer measure the color of beer?
- What are absorption, excitation and emission spectroscopy?
- How are Spectrophotometer s used to measure hot liquid samples?
- Spectrophotometer 100% T Uncalibrated light path inspection
- Test method for light transmittance of adhesives
- ActiveGB/Z 38062-2019
- ActiveGB/T 27594-2025
- ActiveGB/T 713.2-2023
- ActiveSL/T 788.4-2019
- ActiveSL/T 788.5-2019
- ActiveSL/T 788-2019
- ActiveHJ 668-2013
- ActiveSL/T 788.1-2019
- ActiveGB/T 6730.89-2024
- ActiveHB 20056.1-2011
- ActiveYB/T 4217.1-2010
- ActiveJC/T 1040-2020
- ActiveJY/T 0570-2020
- ActiveQX/T 216-2013
- Active 01010102-2006
- ActiveGB/T 15262-1994
- ActiveGB/T 15516-1995
- ActiveGB/T 16129-1995
- ActiveGB/T 32606-2016
- ActiveGB/T 40998-2021


723S(PC)