YUEFENG 770S UV-Visible Spectrophotometer full-band/sub-band scanning
Proportional double beam of light, 1200 line grating, 2nm, 190~ 1100nm, +/- 0.5nm, stray light ≤ 0.15% T, 7 inch touch screen, automatic adjustment 0/100, full band scanning, octagonal cell
YUEFENG-
JINGHUA 755B Automatic UV-Visible Spectrophotometer High Performance Grating, Large Sample Chamber
$ 1499.00 -
YUEFENG 754 UV-Visible Spectrophotometer 195~ 1000nm Bandwidth 4.0nm
$ 924.00 -
JINGHUA H300 Dual beam of light Spectrophotometer Wavelength range 190nm-1100nm
$ 2747.00 -
YUEFENG 752N UV-Visible Spectrophotometer
$ 774.00 -
JINGHUA 2cm Colorimetric dish, width 2cm
$ 101.00
Features
It adopts 7-inch color touch LCD display, which is flexible and convenient to operate.
It adopts proportional double-beam monitoring optical path structure, high-performance, low stray light "blazed holographic grating", high-resolution monochromator, and has outstanding measurement accuracy, accuracy, reproducibility and stability.
It has a unique automatic adjustment "0" adjustment "100", eight sample pool linkage. It has various advanced functions such as full-band scanning (only applicable to 770S), sub-band scanning (only applicable to 770S), kinetic time scanning, GOTOλ, linear regression, direct reading of concentration, peak and valley detection, etc.
Connected to a printer, data printing can be performed, and printing functions such as spectral scanning (only applicable to 770S), fixed wavelength time scanning, and linear regression curves can be realized.
Professional power-off protection measures can memorize test data, scan maps, regression equations, and instrument correction values, etc., and realize rapid initialization and enter the test state when starting up.
The instrument uses a high-energy, long-life flange to position the deuterium lamp. Easy to replace, no need for tedious light path adjustment.

YUEFENG 770S UV-Visible SpectrophotometerSpecifications
| LIST | VALUE |
|---|---|
| Optical inspection system | Proportional double beam of light, 1200/mm Holographic grating |
| Light spectrum bandwidth | 2nm |
| Wavelength range | 190~1100nm |
| Wavelength Accuracy | ±0.5nm |
| Wavelength Repeatability | ≤0.2nm |
| Photometric range | 0.0%~200.0%T、-0.301~4.000A |
| Photometric Accuracy | ±0.5%T |
| Luminosity, sexual repeability | ≤0.2%T |
| stray light | ≤0.15%T@220nm,360nm |
| Noise level | 100%(T):≤0.2%(T) 0%(T):≤0.1%(T) |
| Baseline flatness | ±0.002A (200nm ~1090nm) |
| printout | RS232 print interface |
| light source | Deuterium lamp, tungsten halogen lamp |
| Drift | ≤0.0009A/0.5h@250nm、500nm |
| Environment temperature | 5 ℃~35℃,≤85% |
| Scanning speed | Fast, medium, slow |
YUEFENG 770S UV-Visible Spectrophotometer Packing list
host X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- UV-Visible Spectrophotometer for Evaluating Light spectrum Transmittance of Agricultural Conversion Films
- Determination of specific additives in Adhesives by UV spectrophotometer
- Application of Spectrophotometer in Spectral Reflectance
- How does a Spectrophotometer measure the color of beer?
- How are Spectrophotometer s used to measure hot liquid samples?
- Does paint color affect product quality?
- Application of ultraviolet spectrophotometer in detection of inks harmful substances
- Understanding tristimulus values: eliminating guesswork from the Colorimeter
- What are absorption, excitation and emission spectroscopy?
- UV-Visible Spectrophotometer for Light spectrum Absorption of Perovskite Thin Films
- ActiveGB/T 713.2-2023
- ActiveSL/T 788.4-2019
- ActiveSL/T 788.5-2019
- ActiveSL/T 788-2019
- ActiveHJ 668-2013
- ActiveSL/T 788.1-2019
- ActiveGB/T 6730.89-2024
- ActiveJJF 1641-2017
- ActiveHB 20056.1-2011
- ActiveYB/T 4217.1-2010
- ActiveJG/T 235-2014
- ActiveJC/T 1040-2020
- ActiveSH/T 0409-1992
- ActiveSL 84-1994
- ActiveJY/T 0570-2020
- ActiveQX/T 216-2013
- Active 01010102-2006
- ActiveGB/T 15262-1994
- ActiveGB/T 15516-1995
- ActiveGB/T 16129-1995


770S