NIRUN SNB-3 Digital Viscometer Solder Paste Viscometer Viscosity Range 100~80 million mPa · s
Measurement accuracy of +/- 1.0%, LCD display, can display viscosity, Rotation speed, percentile torque, the maximum viscosity value of the rotor at the current Rotation speed, temperature value.
NiRun-
PUSHEN NDJ-5S Digital Rotational Viscometer 100000mPa.s
$ 521.00 -
MODERNER NDJ-9S Digital Rotational Viscometer 6000000cp
Login -
Viscosity Tester digital Rotational Viscometer 80 million cps
$ 1314.00 -
FANGRUI NDJ-8S Digital Rotational Viscometer with RTD temperature probe
$ 490.00 -
YUEPING NDJ-8S Rotational Viscometer is used in grease, paints, plastics, accessories, Coatings, detergents, etc
$ 610.00
technical features
It can be used as a stand-alone machine, or it can be connected to a micro-printer and a computer to realize data collection.
High subdivision drives the stepper motor to rotate, the speed is accurate and stable, and the frequency change of AC Voltage does not affect the accuracy of viscosity measurement.
For thixotropic non-Newtonian liquids, the timing function of the viscometer can ensure good consistent data.
LCD liquid crystal with blue backlight function, directly display viscosity, speed, percent torque, maximum viscosity value and temperature value of the rotor at the current speed. Viscosity values show a continuous change. There is an alarm sound prompt when the measurement range is exceeded.
SNB data collection and drawing software can be purchased to realize data collection and data analysis, and a miniature monochrome printer can also be purchased to realize regular printing of measurement results.
The instrument's full scale and linearity of each gear are all measured and corrected through the computer interface, and its measurement performance and functions have reached the professional level of the same type abroad.
The standard RTD temperature probe monitors the sample temperature in real time with an accuracy of 0.1°C and a temperature range of 0-100°C.
Using 16-bit microcomputer processor as the core, high subdivision drive stepper motor, digital LCD with blue backlight function.
Different standard rotors can be selected as required.
According to the need, you can choose the standard material of the Metrology Bureau to calibrate the viscometer, so that the inspection level can be in line with the international standard.
Optional SNB data acquisition and drawing software
Applications
SNB-3 digital viscometer is widely used in ink, glue, latex, solvent-based adhesive, polymer solution, petroleum, paint, solvent, cosmetics, milk products, medicine, fruit juice and so on.
Pictures

Optional
Ultra Low Viscosity Adapter (Spindle 0)
micro printer
Special viscosity constant temperature Water Tank
SNB Data Acquisition and Graphing Software
Small sample adapter (with 21#, 27#, 28#, 29# rotors)
standard oil
remote control
Comparison of SNB parameters
| model | Measuring range | Rotor speed | measurement method |
| SNB-1 | 10,000-600,000 | 1-60 | manual |
| SNB-2 | 1-6 million | 0.1-100 | |
| SNB-3 | 4-80 million | 0.1-100 | |
| SNB-AI | 1-6 million, 4-80 million | 0.1-200 | manual, intelligent |
| Unit: mPa·s, rev/min | |||
| Other parameters | |||
| Number of rotors | 4 types of rotors 1, 2, 3, 4 (rotor 0 is optional) | ||
| measurement accuracy | ±1.0% (full scale) | ||
| repeatability | 0.50% | ||
NiRun SNB-3 Digital ViscometerSpecifications
| LIST | VALUE |
|---|---|
| Display | digital display |
| Measuring range | 100~80000000mPa·s |
| Rotor Specifications | 1#、2#、3#、4# |
| Rotor speed | 0.1~100rpm |
| Reproducibility | ±0.5%F.S |
| Measurement Accuracy | ±1% |
| Power | AC100-240V,50Hz/60Hz,DC17V1.2A |
| Weight | 7kg |
| Collection method | continuous acquisition |
| Encasement material | Five-layer cardboard |
| Capacity | 300~400ml |
| Capacity | 400Ml (self-prepared) |
| Lifting system | PE lifting system |
| Bearing system | ruby |
| Torque material | beryllium bronze |
| Control system | microcomputer |
| software system | Data collection, mapping |
| temperature probe | RID temperature probe |
| Encasement | aluminum alloy |
| Speed control method | CVT |
NiRun SNB-3 Digital Viscometer Packing list
host x1, one rotor each for 1 #, 2 #, 3 #, and 4 #, manual x1, warranty card x1.
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Methods for Verifying the Accuracy of a Digital Viscometer
- Viscometer Determination Methods of Several Paints
- Introduction to Several Methods for Determining Relative Viscosity
- Determination of relative viscosity of high viscosity pigment system
- Application of Rotational Viscometer in the viscosity test of circuit board solder paste
- Determination of starch viscosity by swirl/spin Viscosity meter
- What are the selection points for purchasing a solder paste viscometer? How to operate?
- Solder paste viscosity detection steps and instrument introduction
- National Standard for Coating Viscosity Determination [Rotational Viscometer method]
- what is Viscometer?
- ActiveHG/T 4443-2012
- ActiveHG/T 3323-2008
- ActiveDIN 53017-1993
- ActiveNF EN 12092-2002
- ActiveDIN EN 12092-2002
- ActiveGB/T 24148.4-2009
- ActiveGB/T 5547-2007
- ActiveGB/T 13217.4-2020
- ActiveHG/T 3948-2007
- ActiveGB/T 12009.3-2009
- ActiveASTM D3794-2022
- ActiveISO 12634-2017
- ActiveJJG 1002-2005
- ActiveGB/T 22427.7-2008
- ActiveGB/T 18856.4-2008
- ActiveSN/T 2903-2011
- ActiveGB/T 17473.5-2008
- ReplacedHG/T 3323-1982
- ActiveSY/T 0522-2008
- ActiveHG/T 3660-1999


SNB-3
SNB-2
SNB-1