FANGRUI instrument NDJ-8T Digital Rotational Viscometer touch screen 2 million mPa·s
FANGRUI NDJ-8T Digital Rotational Viscometer adopts 5-inch color touch screen and has a front level. NDJ-8T is a high-precision laboratory Viscosity Tester with a measurement Viscosity range of 1 to 2 million mPa·s. NDJ-8T is suitable for cosmetics, Printing ink, pulp, food, oil and other industries.
FangRui-
CNSHP NDJ-1S Digital Rotational Viscometer
$ 411.00 -
FANGRUI LV-SSR digital display Viscometer for a small number of samples
$ 954.00 -
NIRUN NTV-T3L viscosity temperature control machine 1 million CP hot-melt adhesive asphalt paraffin wax and other molten materials
$ 4276.00 -
TQC DV2212 Viscosity calibrated oil N4000 500ml
$ 430.00 -
NIRUN NTV-P2HA Intelligent Digital Viscometer 200~80M mPa · s
$ 3938.00
Introduction
NDJ-8T Digital Display Rotational Viscometer is well integrated with touch screen technology, using a fashionable and modern high technology to measure viscosity quickly, accurately and conveniently. Powerful functions, far from comparable to previous liquid crystal display viscometers.
Self-built 30 sets of test procedures help users to quickly and accurately obtain the viscosity and related data of the sample. The 5-inch super-large color touch screen can comprehensively and vividly display various parameters and Operating Conditions. It has obvious advantages such as many measurement parameters, rich display content, convenient operation, intuitive reading, high measurement accuracy, stable speed, strong anti-interference performance, and wide working Voltage. It can completely replace the imported instruments of the same type, closely following the new technological trend of domestic (CN) viscometers.
NDJ-8T Digital Rotational Viscometer can measure the absolute viscosity of Newtonian liquid or the apparent viscosity of non-Newtonian liquid.
Features
① Using ARM technology, built-in Linux system. The operation interface is simple and clear, and the viscosity test can be performed quickly and conveniently through the creation of test programs and data analysis;
② Viscosity measurement is accurate, and each range is automatically calibrated by computer, with high precision and small error;
③ Rich display content: In addition to viscosity, there are also temperature , the percentage of the measured value to the full scale value (graphic display), range overflow alarm, automatic scanning, the maximum measurement range under the current rotor speed combination, date, time, etc. And it can display the kinematic viscosity when the density is known, which greatly meets the different measurement requirements of users;
④ Complete functions, can measure regularly, build 30 sets of test programs, store and retrieve 30 sets of measurement data, display viscosity curves in real time, print data and curves, etc.;
⑤ Front-mounted spirit level, intuitive and convenient level adjustment;
⑥ Optional temperature probe, constant temperature bath for viscometer, constant temperature cup, printer, standard viscosity sample (standard silicone oil), etc.;
⑦ Chinese and English operating system.
Application
NDJ-8T digital display Rotational Viscometer is widely used in various fluids that need to measure viscosity and fluids under high temperature melting. Including paints, coatings, cosmetics, inks, pulp, food, oil, starch, solvent-based adhesives, latex, biochemical products, etc., as well as industries that require high-temperature melting, such as asphalt, paraffin, hot-melt adhesives, etc.
Pictures

FangRui NDJ-8T Rotational viscometerSpecifications
| LIST | VALUE |
|---|---|
| Display | touch type |
| Measuring range | 1~2000000mPa·s |
| Rotor Specifications | 1#、 2#、3#、4# |
| Rotor speed | 0.3/0.6/1.5/3/6/12/30/60rpm |
| Reproducibility | ±0.5%F.S |
| Measurement Accuracy | ±1% |
| Power | Wide Voltage operation (110V/60Hz or 220V/50Hz) |
| Dimensions | 300*300*450mm |
| Weight | 4kg |
| Capacity | 300~400ml |
| Display shear response/shear rate | Standard |
| Timer | Standard |
| Viscosity Linear dispersion | Viscosity Linear dispersion in real time |
| Sports Viscosity | Display after entering the Density of the sample |
| temperature probe | Standard temperature probe interface (optional temperature probe is required) |
| Automatic scan function | Automatically scan and recommend the best combination of rotor and rotational speed |
| Save measurement results | Up to 30 sets can be stored (including rotor, speed, temperature, time, etc.) |
| Save measurement results | Save up to 30 sets of data (including Viscosity, Temperature, Rotor, Speed, Shear Rate, Shear Stress, Time, Density, Motion Viscosity, etc.) |
| Data Interface | Data, Linear dispersion printable (standard with print interface, optional printer required) |
| Thermostatic parts | Options (including various Viscometer Thermostats, thermostatic cups,) |
FangRui NDJ-8T Rotational viscometer Packing list
Viscometer host x1, 1-4 rotor x1 (set), triangular base x1, column x1, power adapter x1, instrument aluminum box gold foil x1, rotor protection frame x1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Viscometer Determination Methods of Several Paints
- Determination of starch viscosity by swirl/spin Viscosity meter
- How do Rotational Viscometer measurement results compare to Miscellaneous viscosity measurement methods?
- How to choose a Rotational Viscometer? This is enough
- Rotational viscometer selection suggestions
- Working principle and application scenario analysis of NDJ digital Rotational Viscometer
- Application technology and quality control of Rotational Viscometer in pulp and paper manufacturing
- Coating Viscosity Determination Method (Daquan Explanation)
- Printing ink viscosity inspection method
- Digital Viscometer automates liquid viscosity measurement
- ActiveHG/T 4443-2012
- ActiveHG/T 3323-2008
- ActiveDIN 53017-1993
- ActiveNF EN 12092-2002
- ActiveGB/T 24148.4-2009
- ActiveGB/T 13217.4-2020
- ActiveHG/T 3948-2007
- ActiveGB/T 12009.3-2009
- ActiveASTM D3794-2022
- ActiveISO 12634-2017
- ActiveASTM D1795-2021
- ActiveJJG 1002-2005
- ActiveGB/T 22427.7-2008
- ActiveGB/T 12004.4-2003
- ActiveGB/T 18856.4-2008
- ActiveSN/T 2903-2011
- ActiveGB/T 17473.5-2008
- ReplacedHG/T 3323-1982
- ActiveSY/T 0522-2008
- ActiveHG/T 3660-1999


NDJ-8T