MODERNER STM-V Stormer Viscometer without printer 40.2~ 141.0KU
MODERNER STM-V Stormer Viscometer conforms to GB/T9269 standard, with serial printing port, STM-V Stormer Viscometer is a digital display Viscometer, microcomputer control, STM-V is suitable for Coating, paints, inks and other fields.
Moderner-
TQC Sheen DV2300 Krebs Viscometer Stormer Viscometer Coating KU Viscometer
$ 6875.00 -
MODERNER STM-VII Digital Stormer Viscometer
Login -
JINGKELIAN STM-III Stormer Viscometer for determination of paints and Miscellaneous Coating consistency with KU value
$ 480.00 -
PUSHEN STM-V Stormer Viscometer KU/G/CP
$ 1034.00 -
PUSHEN STM-IV Stormer Viscometer KU/G
$ 568.00
Introduction to STM-V Stormer Viscometer
MODERNER STM-V Stormer viscometer is a digital display Stormer viscometer. The control head is a blue metal shell with a handle on the side. The lower part of the control head is connected to a stirring paddle. The viscosity measurement is achieved by computer-controlled rotation of the stirring paddle. , and a display screen displays the measured viscosity value.The measuring viscosity range of the STM-V Stormer viscometer is 40.2KU~141.0KU.
The STM-V Stormer Viscometer is a testing instrument used to measure the viscosity of paints and other coatings with a KU value. The LCD simultaneously displays the KU value of the sample being tested and the load value (unit: g) and reference viscosity value (unit: cP) associated with the KU value.
The Stormer viscometer is microcomputer controlled and has a serial print port. The operator only needs to immerse the stirring blade into the sample to be measured to the specified depth, and the KU value and associated load value of the sample can be read directly from the STM-V Stormer viscometer . Stormer viscometer is designed based on the GB9269 standard.
Structure diagram


Stormer Viscometer Product Picture




Usage environment of STM-V Stormer viscometer
(1) MODERNER STM-V Stormer viscometer should be placed on a solid and flat table away from strong air flow, strong magnetic field, strong electric field, and strong electromagnetic pulse interference.
(2) The temperature in the laboratory should be 25℃±2℃, and the Relative Humidity should not be greater than 75%.
(3) The sample temperature should be 25℃±0.2℃.
Moderner STM-V Stormer ViscometerSpecifications
| LIST | VALUE |
|---|---|
| Display mode | digital display |
| Measurement range | 40.2~141.0KU,32~1099g,27~5274cP |
| Unit display | KU/g/cP |
| Reproducibility | ±1%F.S |
| Accuracy | ±5%F.S |
| Power | 220V/50Hz |
| Interface | serial print port |
| Applicable standards | GB/T 9269 |
| Sample temperature | 25℃±2℃ |
| Dimensions | 210*180*500mm |
| Instrument Weight | 10kg |
| Swirl/spin speed | 200rpm |
| Container size | 500ml |
| Sample temperature | 25℃±0.2℃ |
| Working Relative Humidity | ≤75% |
| Lifting method | Leverage lift |
Moderner STM-V Stormer Viscometer Packing list
host x1, stainless steel cup x1, manual x1, certificate x1, warranty card x1.
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveASTM D562-01-2023
- ActiveASTM D 562-2018
- AbolishGB/T 9269-1988
- ActiveGB/T 9268-2008
- AbolishGB/T 9268-1988
- ActiveGB/T 9269-2009


STM-V