      METASH AA-3300 Flame atomic absorption Spectrophotometer Wavelength: 190~900nm

      METASH flame atomic absorption Spectrophotometer AA-3300 adopts six lamp stand automatic switching device, Wavelength range 190~900nm, Wavelength Precision +/- 0.1nm, with atomic absorption method, hydride method, graphite furnace method, emission method Measuring method.

      Brand
      SKU: NB017616
      China METASH
      Model
      VS
      METASHLOGO

      METASH

      Information
      Genuinegoods
      • METASH AA-3300 Flame/graphite furnace atomic absorption Spectrophotometer Overview

      • Specifications
      • Comments
      • FAQs
      AA-3300
      Flame/graphite furnace atomic absorption Spectrophotometer

      Instrument Features and Functions:

      ◆ A high degree of automation function to better meet the needs of users;

      ◆ Built-in optimization parameters, easy for users to quickly grasp;

      ◆ Automatic wavelength scanning, automatic peak finding, automatic switching of spectral bandwidth, automatic adjustment of negative high Voltage, lamp current, etc., systematic setting or single setting, flexible operation;

      ◆ Acetylene gas leakage alarm, real-time flame monitoring, automatic flame-out protection, automatic power-off protection when other abnormalities occur, to ensure the safety of operators and instruments;

      ◆Excellent scalability, which can easily cope with the diversification and complexity of analytical samples, and easily meet a variety of analysis needs;

      ◆ Adopt six lamp stand automatic switching device to meet the needs of a variety of element testing;

      ◆Using transflective and transflective device, when the deuterium lamp buckles the background, the energy of the sample beam and the background beam is automatically balanced;

      ◆ The atomizer and all-titanium burner with classic design are adopted, which has stable combustion and high atomization efficiency, and ensures the accuracy of analysis.

      VS

      METASH AA-3300 Flame/graphite furnace atomic absorption Spectrophotometer Specifications

      LIST VALUE
      Light spectrum Bandwidth 0.1nm、0.2nm、0.4nm、1.0nm、2.0nm
      Wavelength range 190~900nm
      Wavelength Precision ±0.1nm
      Wavelength Repeatability 0.1nm
      Photometric range 0.001~2.000Abs、0.0001~2.0000Abs
      Baseline flatness 0.004A/30min
      Light source Hollow cathode lamp
      Detector High Sensitivity Imported Photomultipliers
      lamp holder Automatic switching of six lamp holders
      Lamp current Dual loop steady flow Power Supply
      Optical inspection system 1800/mm import grating
      device C-T
      Background correction Deuterium Hollow cathode lamp Background correction
      Combustion head All titanium combustion head, 0.6mm * 100mm titanium steel
      Nebulizer Metal Glass Nebulizer
      Ignition method Electronic torch ignition
      Characteristic concentration 0.02μg/mL/1%(Cu)
      Detection limit 0.002μg/mL(Cu)
      Repeatability RSD≤1.0%
      security Acetylene gas leakage alarm, real-time flame monitoring, automatic flameout protection, automatic power-off protection when Miscellaneous abnormalities occur
      gas control Automatic Gas Control system
      Measuring method Atomic absorption method, hydride method, graphite furnace method, emission method
      Concentration Measurement mode Standard Linear dispersion method, Standard addition method, Absorption method
      Number of repeability measurements Any number of times, can calculate standard deviation, relative standard deviation, Precision

      METASH AA-3300 Flame/graphite furnace atomic absorption Spectrophotometer Packing list

      Host X1, air compressor X1, operating software X1, Hollow cathode lamp X3, Nebulizer X2, screw driver X1, spare parts box X1, air pipe (5 meters) X1, acetylene pipe (5 meters) X1, waste liquid pipe X1, three-core power cord X1, dust cover X1, host signal line X1, acetylene pipe clip X3, acetylene gas source pipe (3 meters) X1, 3A fuse X1, 1.5A fuse X1, certificate X1, warranty card X1, packing list X1

      [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

      FAQ

      [Q]
      Is this spectrophotometer HG/T2471 compliant?
      [A]
      This spectrophotometer is suitable for HG/T2471. Please consult customer service for detailed application definition.