      Home> Gas detector> DuoRui> DuoRui DR-ZJ108 eight channel controller
      DuoRui DR-ZJ108 eight channel controller

      DUORUI DR-ZJ108 eight-channel controller, connected to 8 Gas Detectors

      DUORUI eight-channel controller DR-ZJ108 is a supporting fixed Gas Detector controller, with 8 connection channels, DR-ZJ108 has perfect fault self-detection function, in line with GB16808 standard, DR-ZJ108 eight-channel controller adopts three-wire 3 * 1.0mm2 connection mode.

      Brand
      SKU: NB017776
      China DuoRui
      VS
      DuoRuiLOGO

      DuoRui

      Information
      Genuinegoods
      • DuoRui DR-ZJ108 eight channel controllerOverview

      • Specifications
      • Comments
      • FAQs
      DR-ZJ108
      eight channel controller

      DR-ZJ108 Gas Alarm Controller

      The gas controller samples the analog signal generated by the Gas Detector, and after the data processing of the internal single-chip microcomputer, it can display the concentration, status (sound and light alarm), physical address and other information of the Detector in real time, and output the control signal. It has a complete fault self-detection function, which can display the fault location and type (sound and light alarm) of the system and sub-address in real time.

      The design of this product follows the national standard of GB16808-2008, compared with traditional products, with new functions such as clock display, alarm time checking, independent setting, etc., and the system appearance is beautiful, the display interface is intuitive, the definition is high, and the operation of each function has the corresponding icons to match, the operation is very simple, and the whole product design adopts centralized control, which is convenient for query and maintenance. (Please download the instruction manual from the "Download Center" column)

      Product Qualification Certificate: Type Approval Certificate, Inspection Report, Manufacturing Measuring Instrument License, Explosion-proof Certificate.

      Features

      ◆ High measurement accuracy

      The CPU of the controller adopts high-speed and high-end single-chip microcomputer, which has fast operation speed, high precision and strong reliability, which can quickly and accurately handle system tasks and ensure the reliability of the system.

      ◆ System design

      The system adopts modular structure design, which is convenient for the maintenance and processing of the system.

      ◆ Mixed configuration

      Enables a mix of flammable and toxic Gas Detectors in the same system.

      ◆ Easy to install

      Extremely simple to install and highly operable

      ◆ Analog signal output

      It can output 4-20mA standard current signal, and 2 groups of alarm passive relay contact signal output (switching signal).

      ◆ Easy to maintain

      The whole product design adopts modular structure design, which is convenient for system assembly and maintenance.

      Product Installation

      ◆ Supporting Detectors: DR-600, DR-700 Gas Detectors.

      ◆ Number of connected Detectors: 8 Gas Detectors can be connected.

      ◆ Wiring method with Gas Detector: three-wire system 3*1.0mm2.

      ◆ The gas alarm controller is a non-explosion-proof product, which should be installed in the monitoring room or indoor safe area or in an environment without explosive gas, and should be wall-mounted.

      ◆ Reasonable installation height is selected for installation, which is convenient for operation and not too low to avoid accidental injury to personal beings, and requires the wall to be firm and flat.

      VS

      DuoRui DR-ZJ108 eight channel controllerSpecifications

      LIST VALUE
      Output signal 485 digital signal
      Control output 10 sets of passive relay outputs (switch signal)
      Error of indication ±5%FS
      Response time ≤2s
      wiring method Three-wire system 3 * 1.0mm2
      Shell material Custom iron shell
      Execution standards GB16808-2008
      Operating temperature -20~50℃
      Environmental humidity 0~95% RH non-condensation
      Operating Time 24H continuous online work
      service life 3-5 years (depending on the environment)
      Display LED digital display, LCD display
      display language number
      display content Measured value
      Dimensions 350*450*130mm
      Alarm mode Audio alarm + indicator light alarm
      Power Supply Main power 220V; backup power DC24V, 7AH
      alarm point High/low alarm point
      Display unit %LEL、PPM、%VOL
      Alarm Volume ≥70dB
      transmission distance ≤1200m
      Detect gas Ex, toxic gas
      Weight 10.0Kg
      Number of connected probes Eight.
      Supporting the use of Detectors DR-600, DR-700 gas Detector

      DuoRui DR-ZJ108 eight channel controller Packing list

      machine X1, manual X1, certificate X1, warranty card X1

      [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

      FAQ

      [Q]
      Do you have the eight-channel controller required by the GB3836.1 standard?
      [A]
      This DR-ZJ108 eight-channel controller will do.
      DuoRui
      DUORUI DR-ZJ108 eight-channel controller, connected to 8 Gas Detectors
      Service
      Focus on online sales of Lab Testing Instruments