PUSHEN MFFT minimum film forming temperature (MFFT) Tester
Resin emulsion detection layer heating drying conditions to form a continuous uniform without the lowest temperature of the crazing film, layer plate Operating temperature range -7~ 70 ℃, temperature measurement point 13 points, layer plate size 300 * 200mm, Spreader the number of samples 6.
Pushen-
TQC VF9600 MFFT10 minimum film forming temperature (MFFT) Tester -10~80 ℃
$ 39193.00 -
JINGKELIAN QMB minimum film forming temperature (MFFT) Tester, stainless steel profiled temperature layer
$ 2835.00 -
JINGKELIAN QMB-II minimum film forming temperature (MFFT) Tester GB9267 standard
$ 2779.00 -
TQC VF9700 MFFT20 minimum film forming temperature (MFFT) Tester -30~ + 250 ℃
$ 60310.00 -
PUSHEN MFFT minimum film forming temperature (MFFT) Tester
$ 3568.00
Minimum film forming temperature Tester
It refers to the minimum temperature at which the resin emulsion forms a continuous and uniform film without cracks under gradient heating and drying conditions.
Its main structure is a metal gradient plate, and the two ends of the gradient plate are respectively provided with a cooling source and a heating source. Through the principle of metal heat conduction, different temperature gradients are generated on the metal plate. Coat a wet film of emulsion or compound dispersion with uniform thickness on the temperature gradient plate, dry the sample with dry air flow, and the sample is affected by the temperature on the gradient plate to form a film based on moisture.
Due to the different temperature on the gradient plate, the position of the film formation of the sample is also different. Find the junction point where the continuous transparent film and the white opaque (unpolymerized) are formed . The temperature corresponding to this point on the gradient plate can be obtained from the screen display. The temperature is is the minimum film-forming temperature of the sample.

Standards
GB/T9267
IS0 2115
ASTMD 2354
Pushen MFFT Minimum film forming temperature (MFFT) TesterSpecifications
| LIST | VALUE |
|---|---|
| input Voltage | 220V |
| Layer operation temperature range | -7~70℃ |
| Temperature measurement point | 13 point |
| Layer board size | 300*200mm |
| Number of Applications | Article 6 |
| Test strip size | 240*22mm |
| Overall Dimensions | 520*520*370mm |
| Shipment Weight | 40KG |
Pushen MFFT Minimum film forming temperature (MFFT) Tester Packing list
Host X1, plexiglass cover X1, dryer box X1, catheter X1, Spreader doctor blade X1, fuse X1, manual X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Combined pencil Hardness Tester operating instructions
- Shanghai Pushen pushen film preparation instrument selection table [selection]
- Pushen KTQ Micrometer Film Applicator
- A good manual Ink Proofer from domestic (CN)
- ActiveHG/T 4448-2012
- ActiveGB/T 20623-2006
- ActiveGB/T 9267-2008
- AbolishGB/T 11175-2002
- ISO 2115-1996
- AbolishGB/T 9267-1988


MFFT