PHYNIX Surfix EX-F Coating Thickness Gauge DATASHEET
| Brand |
PHYNIX |
Model |
Surfix EX-F |
| From |
|
Name |
Coating Thickness Gauge |
Specifications
| Measurement principle |
Magnetic Induction |
| Measurement range |
0~1500μm |
| margin of error |
±1% |
| Resolution |
0.1μm |
| probe |
1.5Mm F standard probe |
| Probe contact temperature |
-15~50℃ |
| Probe material |
Tungsten carbide |
| Calibrated mode |
Working calibrated, zero calibrated, single foil calibrated; zero offset |
| statistical function |
Measurement times, MAX Maximum, MIN Minimum, Average, Standard deviation |
| Interface |
USB2.0 |
| Data storage |
2000 Measured values |
| Standards |
DIN,ISO,ASTM,BS |
| system language |
English, German, French, Italian, Spanish, Turkish, Czech and Chinese |
| Display screen |
High resolution color display |
| Operating temperature |
0~50℃ |
| Protection level |
IP52 |
| Machine Weight |
205g |
| Machine size |
137*66*23mm |
Packing list
Integrated host, rubber protective cover, calibrated film, zero standard sheet, 2 AA batteries, PHYNIX.connect transmission software, user manual, manufacturer certificate, Encasement box
After-sales instructions
[Note] For after-sales services outside the Chinese mainland, if the instrument requires repair, the shipping and possible associated taxes shall be borne by the sender. Generation address of the manual: http://en.nbchao.com/p/18262/Specification.html , which is only used by users who purchase commodities from the NBCHAO.