British ION SCIENCE FALCO FAL-10P Fixed VOC Gas Detector Pump suction
The British ION SCIENCE FAL-10P fixed VOC Gas Detector adopts the principle of pump-suction sampling, and the detection range is 0-10ppm. The FAL-10P fixed VOC Gas Detector adopts typhoon technology to prevent the condensation of the PID Detector and has passed the Exd flameproof certification.
Ion Science-
KORNO GT-903-TVOC-Y TVOC Detector, measuring range 0-10PPM
$ 507.00 -
KORNO GT1000-VOC-Y Organic solvent volatile gas, alcohol Detector
$ 727.00 -
KORNO MOT500-TVOC-Y air mass /TVOC Detector 0-10PPM
$ 525.00 -
KORNO MOT500-TVOC-Y Online TVOC Detector 0-500ppm
$ 1751.00 -
KORNO MOT500-VOC-Y Fixed organic solvent volatile gas, alcohol Detector
$ 562.00
Introduction
FALCO Falco fixed VOC online monitor, designed for extreme meteorological conditions and certified for EX d flameproofing, is a satisfactory safety equipment for typical high-risk places of volatile organic gases in the manufacturing and processing industries, and can continuously detect total volatile organic gases.
FALCOPossession of Typhoon technology (Typhoon Technology) can prevent the inside of the instrumentPIDThe Detector forms condensation, and the instrument can operate in condensate environments and in harsh weather. InstrumentalPIDSensors appliedIONGrid electrode technology to reduce reading drift and downtime. Standard on all modelsRS485 [Modbus®]、4-20mAand relay outputs, configurable for high-low output alarms, fault conditions, or test cycle synchronization, plus the instrument's multi-color status display can be viewed from sunlight20The alarm status can be seen clearly from meters away, so it can be realized in the Operating EnvironmentVOCSecurity alarms.
FALCOPump-suction or diffusion options are available, and each has four detection ranges0-10ppm、0-50ppm、0-1000ppm、0-3000ppm。 For locations where measurement is difficult to access, the pump-suction type is the perfect choice; The diffusion type, on the other hand, has very low maintenance costs and does not require maintenance on the pump.
Features
Very good sensor performance, reducing reading drift and downtime
The instruments are available in either suction or diffusion version
For hard-to-access locations, the pump-suction type is the perfect choice
Diffusion sampling reduces contamination in the testing chamber and reduces maintenance costs
Four detection ranges are available
Calibration coefficients can be selected according to different VOC gases
RS485 [Modbus®], 4-20mA and relay output are standard
safe
Intrinsically safe, the instrument is Exd flameproof certified
Accurate results in all environmental conditions
Rugged design for use in harsh environments
The typical lifespan of a high-quality PID detection lamp is up to 2 years
The multi-color status display allows the alarm status to be seen from up to 20 meters away in sunlight

Ion Science FAL-10P Fixed VOC online monitorSpecifications
| LIST | VALUE |
|---|---|
| Sampling method | Pump suction |
| Detection principle | PID |
| range | 10ppm |
| resolution | 0.001ppm |
| Response time | ≤30s(T90) |
| user interface | OLED display: high contrast ratio, black background and white text 128x64px; Screen size: 35x17.5mm; 5 magnetic switches with LED confirmation lights (up, down, left, right, confirmation), with exciter |
| status indicator | Bright and visible status indicators: red, orange, and green |
| certification | Ex II 2G Ex d ib IIC T4 Gb。ISO9001:2008 |
| Operating temperature | -20℃~60℃ |
| Operating humidity | 0~100% Relative Humidity and Humidity |
| Mechanical interface | 2 cable access points with 3/4 "NPT threads (left and right); 2 3/4" NPT threads for M20 stainless steel (configured) |
| Dimension | 290*190*125mm |
| Installation point | 2 M8 |
| Input Power | Operating Voltage: 12~ 40Vdc; Maximum Power: 7W |
| output | 4~ 20mA (active and passive); RS485 supports Modbus protocol; configurable relays and 2 SPST switches |
Ion Science FAL-10P Fixed VOC online monitor Packing list
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Ion Science teaches you how to shock test and calibrate Gas detection equipment?
- What is a VOC (VOC)
- Gas detection Common detection items/detection methods and testing standards
- Common faults and maintenance of Tiger TIGER LT VOC Detector
- Talking about Tiger portable universal data type VOC Gas Detector
- Learn from the policy orientation of European and American countries on VOC emissions from the Coating Industry
- Current Situation and Research Direction of VOC Detection Methods in Air
- British ion Tiger Tiger brand VOC Detector
- Tiger LT series VOC Detector how to calibrate?
- Make it easy for you to use the ionic science tiger VOC Detector


FAL-10P