UK ION SCIENCE FALCO FAL-3000P Fixed VOC Online Monitor, Pump Suction
The UK Ion ION SCIENCE FAL-3000P fixed VOC online monitor is an EX d certified VOC online monitor with a detection range of 0-3000ppm and a resolution of 1ppm. The FAL-3000P has special typhoon technology to prevent the instrument from condensing.
Ion Science-
KORNO GT903-TVOC-Y TVOC Detector, range 0-2ppm
$ 2463.00 -
KORNO GT-903-TVOC-Y TVOC Detector, measuring range 0-10PPM
$ 507.00 -
KORNO MOT500-VOC-Y Fixed organic solvent volatile gas, alcohol Detector
$ 562.00 -
KORNO MOT500-TVOC-Y Online TVOC Detector 0-500ppm
$ 1751.00 -
KORNO MOT500-TVOC-Y air mass /TVOC Detector 0-10PPM
$ 525.00
Introduction
FALCO Falco fixed VOC online monitor, designed for extreme meteorological conditions and certified for EX d flameproofing, is a satisfactory safety equipment for typical high-risk places of volatile organic gases in the manufacturing and processing industries, and can continuously detect total volatile organic gases.
FALCOPossession of Typhoon technology (Typhoon Technology) can prevent the inside of the instrumentPIDThe Detector forms condensation, and the instrument can operate in condensate environments and in harsh weather. InstrumentalPIDSensors appliedIONGrid electrode technology to reduce reading drift and downtime. Standard on all modelsRS485 [Modbus®]、4-20mAand relay outputs, configurable for high-low output alarms, fault conditions, or test cycle synchronization, plus the instrument's multi-color status display can be viewed from sunlight20The alarm status can be seen clearly from meters away, so it can be realized in the Operating EnvironmentVOCSecurity alarms.
FALCOPump-suction or diffusion options are available, and each has four detection ranges0-10ppm、0-50ppm、0-1000ppm、0-3000ppm。 For locations where measurement is difficult to access, the pump-suction type is the perfect choice; The diffusion type, on the other hand, has very low maintenance costs and does not require maintenance on the pump.
Features
Very good sensor performance, reducing reading drift and downtime
The instruments are available in either suction or diffusion version
For hard-to-access locations, the pump-suction type is the perfect choice
Diffusion sampling reduces contamination in the testing chamber and reduces maintenance costs
Four detection ranges are available
Calibration coefficients can be selected according to different VOC gases
RS485 [Modbus®], 4-20mA and relay output are standard
safe
Intrinsically safe, the instrument is Exd flameproof certified
Accurate results in all environmental conditions
Rugged design for use in harsh environments
The typical lifespan of a high-quality PID detection lamp is up to 2 years
The multi-color status display allows the alarm status to be seen from up to 20 meters away in sunlight

Ion Science FAL-3000P Fixed VOC online monitorSpecifications
| LIST | VALUE |
|---|---|
| Sampling method | Pump suction |
| Detection principle | PID |
| range | 3000ppm |
| resolution | 1ppm |
| Response time | ≤30s(T90) |
| user interface | OLED display: high contrast ratio, black background and white text 128x64px; Screen size: 35x17.5mm; 5 magnetic switches with LED confirmation lights (up, down, left, right, confirmation), with exciter |
| status indicator | Bright and visible status indicators: red, orange, and green |
| certification | Ex II 2G Ex d ib IIC T4 Gb。ISO9001:2008 |
| Operating temperature | -20℃~60℃ |
| Operating humidity | 0~100% Relative Humidity and Humidity |
| Mechanical interface | 2 cable access points with 3/4 "NPT threads (left and right); 2 3/4" NPT threads for M20 stainless steel (configured) |
| Dimension | 290*190*125mm |
| Installation point | 2 M8 |
| Input Power | Operating Voltage: 12~ 40Vdc; Maximum Power: 7W |
| output | 4~ 20mA (active and passive); RS485 supports Modbus protocol; configurable relays and 2 SPST switches |
Ion Science FAL-3000P Fixed VOC online monitor Packing list
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- What is a VOC (VOC)
- Learn from the policy orientation of European and American countries on VOC emissions from the Coating Industry
- UK ION SCIENCE Tiger VOC Detector screen display description
- Tiger LT series VOC Detector how to calibrate?
- Ion Science teaches you how to shock test and calibrate Gas detection equipment?
- TIGER LT Series Handheld VOC Detectors
- Make it easy for you to use the ionic science tiger VOC Detector
- Common faults and maintenance of Tiger TIGER LT VOC Detector
- British ion Tiger Tiger brand VOC Detector


FAL-3000P