| Sensors (PID) | 10.6 eV Ion Science grid electrode detection lamp |
| intrinsically safe certification | Hazardous area safety approval. ATEX: II 3 G Ex nA IIC T4 (-40 ℃ ≤ Ta ≤ 50 ℃); IECEX: II Ex ia IIC T4 (-20 ℃ ≤ Ta ≤ 50 ℃) |
| access protection level | IP-65 Wire Bushing; IP-45 Sensors |
| Power Supply | 5-28VDC, maximum 65mA |
| output | 4-20mA (requires 8-35VDC Power Supply) |
| range | 0~10ppm |
| resolution | 0.01ppm |
| Sampling method | Diffusion (External Electric Pump if required) |
| Display | 7-Section display, 4-digit digital LCD, 4-color LED |
| Response time | Sensors T90 < 5s, Detector - 1 minute (standard) |
| Accuracy | 0-100ppm > 98% |
| calibrate | Magnetic, calibrated with 100 ppm isobutylene by calibrating package |
| Operating temperature | -20℃~50℃(-4℉—122℉) |
| Operating humidity | 0~95% RH (non-condensing) |
| Weight | 1.3kg(2.9lb) |
| Encasement Weight | 1.47kg(3.2lb) |
| Dimension | 120*160*70mm |
| Sensors principle | PID |
None