Nix Fe/NFE2mm Thickness Gauge Probe QNix7500 Thickness Gauge Special
The German QNix Fe/Nfe2mm Thickness Gauge probe is the matching probe of the QNix7500 anti-corrosion layer Thickness Gauge, the thickness measurement range is 0~2000 microns, and the Fe/Nfe2mm Thickness Gauge probe is a magnetic eddy current dual function.
Qnix-
Germany Nix QNix 4500 + FN3 integrated dual-use coating platings Thickness Gauge FeNFe dual-use probe 0-3000μm
$ 964.00 -
IPRE CT400 magnetic Induction eddy Current Coating Thickness Gauge Measurement range 0~1500μm
$ 256.00 -
Defelsko N built-in detachable probe
$ 648.00 -
Defelsko PosiTector 6000 F90S3 Coating Thickness Gauge 90 ° probe nonmagnetic Coating thickness measurement
$ 1769.00 -
List Magnetik TOP-CHECK Dual platings Thickness Gauge
$ 1794.00
Introduction
The German QNix Nix Fe/Nfe2mm Thickness Gauge probe is a magnetic induction and eddy current dual-purpose coating Thickness Gauge, with a thickness measurement range of 0~2000 microns, and the Fe/Nfe2mm Thickness Gauge probe is a supporting probe of QNix7500 anti-corrosion layer Thickness Gauge, with a measurement accuracy of 0-50μm: ≤±1μm, 50-1000μm: ≤±1.5%, 1000-2000μm: ≤±2%.

Qnix 7500 Probe Model Chart
| Model | Fe-2000 | Fe-5000 | Nfe-2000 | Nfe-5000 | Fe/Nfe-2000 | Fe/Nfe-5000 |
| matrix | iron | iron | Non-iron | Non-iron | Iron/non-ferrous | Iron/non-ferrous |
| Probe form | One/Split | One/Split | One/Split | One/Split | One/Split | One/Split |
| Measuring range | 0~2000μm | 0~5000μm | 0~2000μm | 0~5000μm | 0~2000μm | 0~5000μm |
| Measurement accuracy | 0~1999μm:±(1μm+2%) | 0~1999μm:±(1μm+2%); 2000~5000μm:±3.5% | 0~1999μm:±(1μm+2%) | 0~1999μm:±(1μm+2%); 2000~5000μm:±3.5% | 0~1999μm:±(1μm+2%) | 0~1999μm:±(1μm+2%); 2000~5000μm:±3.5% |
| Minimum measuring surface | Fe:φ25mm;NFe:φ25mm | |||||
| Minimum radius of curvature | Convex φ5mm, concave φ25mm | |||||
| Minimum substrate thickness | Fe:200μm;NFe:50μm | |||||
Qnix 7500 Fe/Nfe2mm probeSpecifications
| LIST | VALUE |
|---|---|
| Measurement principle | Magnetic Induction + eddy Current |
| Measurement range | 0~2000μm |
| margin of error | ±2% |
| Minimum measurement surface | Φ25mm |
| Minimum radius of curvature | Convex: 5mm; Concave: 25mm |
| thinnest substrate | Fe:200μm;NFe:50μm |
| Interface | USB or RS232 |
Qnix 7500 Fe/Nfe2mm probe Packing list
Probe X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Specific operation steps of the three methods of surface contour measurement
- How does the QNix Coating Thickness Gauge maintain accuracy?
- Concept and basic knowledge of coating Thickness Gauge
- ActiveGB/T 44757-2024
- ActiveJJG 818-2018
- ActiveGB/T 1727-2021
- ActiveHG/T 20720-2020
- ActiveHG/T 5367.1-2018
- ActiveASTM B244-2021
- ActiveISO 2360-2017
- ActiveISO 2178-2016
- ActiveASTM D7091-2022
- ActiveASTM B499-2021
- ActiveISO 19840-2012
- ActiveGB/T 1740-2007
- ASTM E376-2019
- ActiveISO 2808-2019
- AbolishJJG 889-1995
- AbolishJJG 818-1993
- ActiveGB/T 4956-2003
- ISO 2361-1982
- ActiveHG/T 3885-2006
- ActiveGB/T 6463-2005


7500 Fe/Nfe2mm