      Home> Fineness Gauge> Moderner> Moderner QXD-100 (large double-channel) Large double-channel Fineness gauge

      MODERNER QXD-100 Large double-channel lithium battery paste Fineness gauge Fineness range 0~100μm

      Large double-channel, 0~100μm, scale unit μm, Hegman, stainless steel, suitable for standards GB/T 1724, GB/T 13217.3, ISO 1524, ASTM D1210.

      Brand
      SKU: NB018541
      Boutique China Moderner
      Stock
      Loading…
      Price
      Please contact customer service
      Promotion
      Service
        Service
        The delivery and service By NBchao.Com
        VS
        Genuinegoods
        • Moderner QXD-100 (large double-channel) Large double-channel Fineness gaugeOverview

        • Specifications
        • Comments
        • FAQs
        QXD-100 (large double-channel)
        Large double-channel Fineness gauge
        • MODERNER QXD-100 Large double-channel lithium battery paste Fineness gauge Fineness range 0~100μm
        • MODERNER QXD-100 Large double-channel lithium battery paste Fineness gauge Fineness range 0~100μm Figure 1
        • MODERNER QXD-100 Large double-channel lithium battery paste Fineness gauge Fineness range 0~100μm Figure 2
        Large double-channel, 0~100μm, scale unit μm, Hegman, stainless steel, suitable for standards GB/T 1724, GB/T 13217.3, ISO 1524, ASTM D1210.

        In the MODERNER, there are various specifications for the research and development and design of the Fineness of Grind Gauge, including general single and double grooves, wide grooves, and large and wide grooves. This large double-slot Fineness of Grind Gauge is a Fineness of Grind Gauge with a large chute width. The QXD-100 large double-slot Fineness of Grind Gauge has a measuring range of 0~100μm, a division value of 5μm, and a chute width of 25.4mm. Applicable to some users with special needs.

        The large double-slot fineness scraper QXD-100 conforms to the national standard and is mainly used to measure the fineness of particles such as pigments and impurities in paints and paint pastes. The large double-groove fineness scraper is made of stainless steel, and it is equipped with a 95mm scraper. The width of the chute is larger than that of the general fineness plate. The fineness scraper is designed and manufactured according to JJG (Chemical) 018-96 "Grindometer" and its GB/T1724 standard of the Ministry of Chemical Industry of the People's Republic of CHINA for the verification of special equipment for coatings.

        Features

        1) QXD-100 large double-slot Fineness of Grind Gauge is widely used in the determination of the grinding fineness of paint, varnish, printing ink and other materials

        2) The fineness is expressed in microns (μm) or Hegman grades (Hegman)

        3) Compliance with standards: GB/T 1724, GB/T 13217.3, ISO 1524, ASTM D1210

        4) QXD-100 large double groove Fineness of Grind Gauge is made of stainless steel

        real shot

        MODERNER QXD-100 large double groove Fineness of Grind Gauge display

        Details of MODERNER QXD-100 large double-slot Fineness of Grind Gauge

        MODERNER QXD-100 large double groove Fineness of Grind Gauge groove details

        MODERNER QXD-100 large double groove Fineness of Grind Gauge material details

        Steps for usage

        (1) The QXD-100 Fineness of Grind Gauge should be soaked with a suitable solvent before use, including the scraper and the bottom, and dried with cotton yarn, and the sample that meets the product standard viscosity index should be fully stirred with a paint knife .

        (2) In the deepest part of the groove of the QXD-100 large double-groove Fineness of Grind Gauge , drop a few drops of the sample, it is better to fill the groove with a little excess.

        (3) Hold the scraper with the thumb, index, and middle fingers of both hands. Place it horizontally on the upper end of the double-groove Grindometer, make the scraper perpendicular to the surface of the Grindometer, and pull the scraper from the deep part of the groove to the shallow part at an appropriate speed, so that the paint sample fills the groove without leaving any residue on the plate. There is excess paint.

        (4) Immediately (not more than 5 seconds) after scraping, pinch the fineness gauge horizontally and tilt it so that the line of sight is 15-30° from the groove plane and observe the scale value of the uniformly exposed particles in the groove. The reading value is The fineness value of the measured object.

        Precautions

        (1) Do not scratch the surface of the Grindometer and the scraper

        (2) Clean the QXD-100 large double-slot Grindometer immediately after use and apply Vaseline to prevent rust

        (3) When measuring the fineness, the clear oil that meets the product standard should be adjusted before measuring

        (4) Regularly (one year) check the knife edge and the straightness of the fineness gauge, and if it is found to be uneven or the Grindometer is worn, it needs to be calibrated by the national metrology and verification agency before it can be used.

        Specification list

        MODERNER Fineness of Grind Gauge series specification list

        MODERNER full range of Fineness of Grind Gauge specification parameter table

        Series

        SpecificationRangeDivision valueGroove sizeunit
        small single slot0-150.7512.7*140μm
        0-251.25Hegman/μm
        0-502.5
        0-1005
        0-1505μm
        small double slot0-252.5Hegman/μm
        0-502.5
        0-1005
        0-1505μm
        wide slot0-251.2525.4*127Hegman/μm
        0-502.5
        0-1005
        large wide groove0-252.550.8*127
        0-505
        0-1005
        Big double slot0-252.525.4*165Hegman/μm/NPIRI
        0-505
        0-1005
        Special double slot0-502μm
        0-25010μm



        VS

        Moderner QXD-100 (large double-channel) Large double-channel Fineness gaugeSpecifications

        LIST VALUE
        Scraper type Big double-channel
        Number of grooves 2
        range 0 ~ 100µm
        Scale unit μm、Hegman
        Scraper material stainless steel
        Scraper size 241.3*88.9*19.05mm
        Groove size 25.4*165mm
        Scraper material stainless steel
        Scraper size 95mm
        Applicable standard GB/T 1724、GB/T 13217.3、ISO 1524、ASTM D1210

        Moderner QXD-100 (large double-channel) Large double-channel Fineness gauge Packing list

        Scraper x1, scraper x1

        [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

        FAQ

        [Q]
        0-100 microns, scale interval 5 microns, double-channel, effective groove size 25mm * 165mm is available?
        [A]
        MODERNER QXD-100 Large double-channel Fineness of Ground Gauge
        [Q]
        Can this instrument measure the dispersion of Printing ink?
        [A]
        If there is no direct test of dispersion, the Fineness gauge tests the particle size of the sample, and the approximate dispersion can be judged by the Fineness size.
        [Q]
        Do you have the Fineness of Ground Gauge required by the JT/T821.3 standard?
        [A]
        This QXD-100 (large double-channel) Fineness of Ground Gauge will do.
        [Q]
        I want to measure the cleanliness of emulsion paint. Is this Fineness Meter suitable?
        [A]
        The number of particles in the emulsion paint above the Fineness meter reading is suitable for indicating the cleanliness of the emulsion paint and is therefore appropriate.
        [Q]
        Can the QXD100 large double-channel Fineness gauge detect coatings close to 75 microns?
        [A]
        In line with the large double-channel scraper fineness Measurement range can scrape material fineness below 0~ 100μm.
        Moderner
        MODERNER QXD-100 Large double-channel lithium battery paste Fineness gauge Fineness range 0~100μm
        Service
        Focus on online sales of Lab Testing Instruments