MODERNER RJD-10 Pressure sensitive adhesive solubility Tester
MODERNER RJD-10 Pressure sensitive adhesive solubility Tester conforms to GB/T34716 standard and is dedicated to Adhesive solubility measurement. RJD-10 Pressure sensitive adhesive solubility Tester is suitable for various biological and chemical laboratories with high requirements for Oscillation Frequency and temperature accuracy.
Moderner-
YUZHOU ZXQ-1 Automatic Metallographic Specimen Inlay Machine Mold Cover Specifications < unk > 40mm
Login -
DUBAN DB25-ATP-A5 ATP Fluorescence Bacteria Detector (Standard)
$ 404.00 -
DUBAN DB22-FPM42K Stroboscope 50~42000 FPM
$ 374.00 -
Jingyi JY-30A3 automatic forward and reverse swirling/spinning oil mixer
$ 2527.00 -
MODERNER RYK heat source block, bottom diameter φ 100mm
Login
Introduction
The RJD-10 solubility Tester is designed to meet the needs of adhesive solubility measurement. It can also be used for bacterial culture, fermentation, hybridization and biochemical reactions as well as enzyme and cell tissue research that have high requirements on temperature and oscillation frequency.
main feature
RJD-10 pressure-sensitive adhesive solubility Tester is suitable for various biological and chemical laboratories that have high requirements for oscillation frequency and temperature accuracy.
âHigh-strength and high-performance mechanical transmission design, it can still run smoothly even under overload conditions.
âIt has a power outage recovery function. After the external power supply suddenly loses power and comes back again, the equipment can automatically resume operation according to the original setting program.
âDouble over-temperature protection design. When the water level of the heater component is too low and the test sample is over-temperature, the host can automatically cut off the heating power.
âMicroprocessing chip PI type temperature control design, the temperature control has good linearity, small fluctuations, and the temperature uniformity reaches 0.1℃.
âThe LCD displays the set temperature and actual temperature.
âWith operating parameter memory function, it can avoid repeated and cumbersome operations.
âMicroprocessor chip frequency control, LCD display shows the set frequency and actual frequency.
âComplete timing setting function, any time can be set between 1 minute and up to 500 hours. The timing endpoint equipment can automatically stop and issue audible and visual alarms.
âWhen the actual measured temperature deviates from the set temperature by 3℃, the host automatically stops heating and sounds an audible alarm.
âThere is a drain valve on the side of the Water Bath.
âImported stainless steel liner, stainless steel electropolished rocking plate, spring, and flask clamp.
âFlexible, convenient and detachable rocking plate assembly with various specifications.
Product display picture

Standards compliant
GB/T34716-2017 Determination of solubility of pressure-sensitive adhesives
Moderner RJD-10 Pressure sensitive adhesive solubility TesterSpecifications
| LIST | VALUE |
|---|---|
| Product model | RJD-10 |
| Swirl/spin Frequency | 20~250r/min±10% |
| Amplitude | 24mm |
| configuration | 250Ml * 10 sticks |
| Rocking board size | 450*260mm |
| Timer Timing range | 500 hours |
| Digital display | LCD |
| Temperature range | Room temperature + 5 ℃~ 99 ℃ |
| Temperature control Accuracy | ±0.1℃ |
| Temperature Uniformity | +/- 0.5 ℃ (when oscillating) |
| Power | 1270W/1550W |
| Power | AC220V±10% 50Hz±2% |
| Oscillation mode | round trip |
Moderner RJD-10 Pressure sensitive adhesive solubility Tester Packing list
Whole machine X1, flask X10, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.


RJD-10





