      Home> Coating Thickness Gauge> DongRu> DongRu DR360 Coating Thickness Gauge

      DONGRU DR360 metal Thickness Gauge, professional measurement of the thickness of coated platings

      Dual-function metal Thickness Gauge, thickness range 0~1250 microns, touch button operation, imported metal probe, support zero and two point calibrating, in line with GB/T 4956 standard.

      Brand
      SKU: NB000187
      China DongRu
      Model
      Stock
      Loading…
      Price
      $ 350.00
      Promotion
      Service
        Service
        The delivery and service By NBchao.Com
        VS
        Genuinegoods
        • DongRu DR360 Coating Thickness GaugeOverview

        • Specifications
        • Comments
        • FAQs
        DR360
        Coating Thickness Gauge
        • DONGRU DR360 metal Thickness Gauge, professional measurement of the thickness of coated platings
        • DONGRU DR360 metal Thickness Gauge, professional measurement of the thickness of coated platings Figure 1
        • DONGRU DR360 metal Thickness Gauge, professional measurement of the thickness of coated platings Figure 2
        Dual-function metal Thickness Gauge, thickness range 0~1250 microns, touch button operation, imported metal probe, support zero and two point calibrating, in line with GB/T 4956 standard.

        Coating Thickness Gauge Selection Tool

        Introduction

        Dongru DR360 Metal Thickness Gauge is a coating Thickness Gauge with a split structure and a dual-function magnetic coating Thickness Gauge. The DR360 metal Thickness Gauge is operated by touch buttons, and the measured data is displayed on the LCD, which is convenient for reading. The probe of the metal Thickness Gauge adopts a small measuring head of imported high-quality metal material, which makes the thickness measurement more accurate and reliable. The measurement range is 0~1250 microns, and the minimum measurement substrate is 0.3mm.

        Dongru DR360 Metal Thickness Gauge is a method that applies the principle of electromagnetic induction. It can non-destructively measure the thickness of non-magnetic coatings (such as: paint, electrophoresis, powder, galvanized, chromium, copper, indium, enamel, rubber, enamel, anti-corrosion layer, paint) on magnetic metal substrates (such as: steel, iron) etc.), easy to use, easy to carry, LCD display, large font size, backlight direct reading is clearer, precise and firm structure, better repeatability, and excellent performance.

        Features

        1. The DR360 metal Thickness Gauge has a variety of measurement modes to choose from

        2. There are two optional modes of continuous test and single measurement; continuous test can effectively reduce human error and make the measured value more accurate.

        3. It can count the maximum value, minimum value, average value, and measurement times. It can be completed with one key, good, effective, and convenient.

        4. Fast test speed, high sensitivity, beautiful appearance and fine workmanship

        5. DR360 metal Thickness Gauge adopts imported high-quality metal small measuring head, which has more stable performance, wear resistance and pressure resistance, and long service life

        6. Fully intelligent touch buttons, non-slip type, unique design, novelty, humanization, compact structure, professional technology

        7. Large LCD display, backlight, large font size display, clear and accurate reading height at any angle

        8. With data storage function, stable storage

        9. Large-capacity storage, which can store more than 800 measurement data, connect to the computer to read the data and print and save

        10. Two calibration methods can be used: zero-point calibration and two-point calibration, two-point calibration is more accurate.

        11. DR360 Coating Thickness Gauge has a buzzer sound during operation (single measurement mode)

        12. Metric and imperial conversion μm/Mil

        13. Low Voltage indication

        14. Manual/automatic shutdown function

        Standards

        According to the national industry: GB/T 4956-1985 standard, DR360 metal Thickness Gauge is a professional non-destructive testing instrument for measuring the thickness of magnetic metal material surface coating layer objects.

        VS

        DongRu DR360 Coating Thickness GaugeSpecifications

        LIST VALUE
        Measurement principle Magnetic Induction + eddy Current
        Measurement range 0 ~ 1250µm
        margin of error ±1~3%
        Resolution 0.1mm | 1mm
        Minimum radius of curvature Convex 5mm; Concave 25mm
        thinnest matrix 0.3mm
        probe F and N split probes
        Statistical function Average, MAX Maximum, MIN Minimum, Number of Tests
        icon function without
        Power Three (7) alkaline batteries
        Standards GB/T 4956-1985
        Calibrated Certificate without
        Language Chinese, English
        Display screen 2.3-Inch large color screen large font size display
        supporting software without
        Total Weight 100g
        Complete-built unit size 130*70*25mm
        Minimum measurement surface F11.5mm
        Operating Environment Temperature: 0 ℃ -60 ℃, Humidity: 20% RH - 90% RH, use in environment without strong magnetic field
        Unit display μm / Thousand
        Shutdown method Manual/Automatic
        data storage It can be stored in 10 groups, 200 in each group, and a total of 2000 data can be stored
        Calibrated mode Zero point calibrated, two point calibrated, multi point calibrated

        DongRu DR360 Coating Thickness Gauge Packing list

        Thickness gauge x1, calibrated diaphragm (50, 100, 250, 370 μm) x4, iron matrix x1, ABS instrument Encasement box x1, battery x1, manual x1, certificate x1, cleaning cloth x1

        [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

        FAQ

        [Q]
        Which national standard does the DR360 thickness gauge meet?
        [A]
        It meets the national standard GB/T 4956-1985.
        [Q]
        What principle is used for measurement?
        [A]
        It uses the principle of electromagnetic induction for measurement and realizes nondestructive measurement.
        [Q]
        What Measurement modes are available?
        [A]
        Measurement modes are available for the DR360, including Continuous Test and Single Measurement modes for improved measurement accuracy.
        [Q]
        Which national standard does the DR360 thickness gauge meet?
        [A]
        It conforms to the national standard GB/T 4956-1985 and is a professional nondestructive testing instrument for the measurement of the thickness of metal materials coated with platings.
        [Q]
        How to display measurement data?
        [A]
        It displays measurement data via a large LCD screen with a backlight and large font size, ensuring highly clear and accurate readings at any angle.
        +DongRu DR360 Coating Thickness Gauge Big data
          +DongRu DR360 Coating Thickness GaugeSimilar products
          +DongRu DR360 Coating Thickness GaugeKnowledge
          +DongRu DR360 Coating Thickness GaugeStandard
          +Navigation
          DongRu
          DONGRU DR360 metal Thickness Gauge, professional measurement of the thickness of coated platings
          Service
          Focus on online sales of Lab Testing Instruments