RONGJIDA JQ-III formaldehyde climate Test Chamber
RONGJIDA JQ-III formaldehyde climate Test Chamber is used to test the concentration of formaldehyde in wood, furniture, flooring, building decoration materials, etc. The temperature adjustment range of JQ-III Formaldehyde climatic chamber is 10~40 ℃, humidity range 30%~ 80%.
RongJiDa-
Ring instrument HYV-60-6 VOC equilibrating chamber 6 barrel type
Login -
Ring instrument HYV-60-4 VOC equilibrating chamber 4 barrel type
Login -
HYV-1000 1 cubic meter VOC emission environment Test Chamber
Login -
HYQC-1500 1.5 cubic meters environment Test Chamber Glass
Login -
HUANGYI HYQ-1000L 1 cubic meter formaldehyde release environment Test Chamber
Login
Equipment use
The 1m 3 formaldehyde climate chamber is mainly used for the determination of free formaldehyde in consumer products such as wood products, furniture, floors, carpets, footwear products, and building decoration materials.
product description
Put the test piece with known surface area into the test box where the temperature, humidity, air velocity and air replacement rate are controlled at a certain value. Formaldehyde is released from the test piece and mixed with the air in the box. The air in the box is regularly extracted, and the air is drawn from the box to measure the concentration of formaldehyde absorbed in the water through a washing bottle filled with water. The formaldehyde concentration of the air in the Test Chamber is calculated from the formaldehyde concentration in the scrubber bottle and the volume of the extracted air, expressed in milligrams per cubic meter (mg/m3). Sampling is periodic until the formaldehyde concentration in the Test Chamber reaches equilibrium.
design reference standard
"Limits of formaldehyde release in wood-based panels and their products for interior decoration and decoration materials" (GB 18580-2017);
"Standard Test Method for Formaldehyde Concentration and Release Rate in Air Released from Wood Products in Large Environmental Chambers" ASTM E 1333-96
"Standard Test Method for Formaldehyde Concentration in Air Released from Wood Products by Small-Scale Environmental Chamber" ASTM D 6007-02
"Environmental Chamber Method for Measuring Formaldehyde Emission from Wood-based Panels" EN 717-1
"Test methods for physical and chemical properties of wood-based panels and veneer wood-based panels" (GB/T17657-2013)
"Limits of Hazardous Substances in Wood Furniture for Interior Decoration Materials" (GB18584-2001);
"Indoor Decoration Materials Carpet, Carpet Backing and Carpet Adhesive Release Limits of Hazardous Substances" (GB18587-2001);
"1M3 climate chamber for detection of formaldehyde emission" (LY/T1980-2011);
"Determination of Formaldehyde Emission from Plates by 1M3 Climate Chamber Method" (ISO 12460-1.2007)
"1m 3 climate chamber for detection of formaldehyde emission" (LYT 1612-2004)
Features
●Professional heat exchanger technology: high heat transfer efficiency and small temperature gradient;
●Hot and cold resistance temperature adjustment Water Tank: temperature control is stable;
●Imported humidity temperature and humidity sensor: the sensor has high precision and stable performance;
●Excellent refrigerator: imported refrigerator, stable operation and long service life;
●Protection device: the Climate Chamber and the dew point Water Tank have high-low temperature alarm protection measures and high-low water level alarms;
●Protection measures; the compressor also has overheating, overcurrent and overpressure protection measures, and the whole machine is safe and reliable in operation;
●Stainless steel inner box: the inner cavity of the constant temperature box is made of mirror stainless steel, the surface is smooth and does not condense, does not absorb formaldehyde, and ensures the detection accuracy;
●The constant temperature box is made of hard foam material, and the door of the box is made of silicone rubber sealing strip, which has good thermal insulation performance and sealing performance. The box is equipped with a forced air circulation device (forming a circulating air flow) to ensure that the temperature and humidity in the box are balanced and consistent.
Equipment Control System
1. Instrument: Shenzhen Xianke
2. Sensor: Honeywell far-infrared temperature and humidity integrated sensor
2. Contactor: French Schneider
3. Relay: Japan Omron
4. Thermal relay: French Schneider
5. Contactor: French Schneider
6. Terminal block: French Schneider
7. Heater: CHINA Pengda electric tube (manufacturer promises to work continuously for 8000 hours)
8. Water pump: Wilo, Germany




RongJiDa JQ-III Formaldehyde climate Test ChamberSpecifications
| LIST | VALUE |
|---|---|
| Ambient Temperature | 15~30℃ |
| Relative Humidity | ≤90%RH |
| Temperature range | 10~40℃ |
| Temperature control Accuracy | ±0.1℃ |
| Temperature Fluctuation | ≤±0.5℃ |
| Temperature Uniformity | ≤±0.5℃ |
| Humidity control range | 30~80 % R.H. |
| Humidity control range | ±2% R.H. |
| Humidity stability | ≤±3% RH |
| Humidity Uniformity | ≤±5% RH |
| air exchange rate | 1m3/h,±5% |
| pressure | 10±5Pa |
| Flow velocity | 0.1~ 0.3M/s (continuously adjustable) |
| Flow velocity Accuracy | ≤0.05m/s |
| Air tightness | At 1kPa positive pressure (gauge pressure), the air leakage rate in the cabin is less than 10-3 * 1M3/min |
| Gas flow rate difference | <1% |
| Chamber material | 304 mirror stainless steel plate seamless welding |
| Enclosure Material | A3 Color plating electrostatic spraying (ES) |
RongJiDa JQ-III Formaldehyde climate Test Chamber Packing list
machine X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveJG/T 527-2017
- ActiveSN/T 3026-2011
- ActiveLY/T 1982-2011
- ActiveLY/T 1981-2011
- ActiveLY/T 1612-2004
- ActiveGB/T 43353-2023
- ActiveGB/T 33043-2016


JQ-III