PUSHEN ISO-8 ISO Flow Cup 8mm/aluminum single cup
Outflow time 30~100s, flow hole diameter 8mm, cup height 86mm, cup width 56mm, Total height 86mm, cup body material anodic oxidation aluminum, filter material stainless steel, Applicable standards ASTM D5125, ISO 2431.
PushenThe ISO outFlow Cup is designed and manufactured in accordance with the relevant provisions of the international standard ISO2431-1993 for the determination of the outflow time and the national standard GB/T6753.4-98 for the determination of the outflow time of paints - ISO outFlow Cup method. This outFlow Cup is used to test the outflow time of Newtonian or near-Newtonian liquids.
Main technical parameters:
| Model | Outflow pore size | Measuring range | Run out of time | The width of the cup | Cup height | weight | Meets standards |
| Number 3 | 3mm | 7-42 cSt | 30-100s | 56mm | 86mm | 268g | ASTM D 5125,ISO 2431 |
| Number 4 | 4mm | 34-135 cSt | 25-100s | ||||
| Number 5 | 5mm | 91-326 cSt | 25-100s | ||||
| Number 6 | 6mm | 188-684 cSt | 25-100s | ||||
| Number 8 | 8mm | -- | Customized | ||||
| Note: Brackets can be purchased separately | |||||||
The actual picture of the ISO outFlow Cup



Equipment and utensils
1. Stopwatch: Accuracy 0.1 (bring your own)
2. OutFlow Cup holder (optional)
How to use:
1. Before or after measuring, wipe the inner wall with fine gauze dipped in the solution repeatedly, twist it into a rope shape with soft paper, and repeatedly pull it clean in the outflow hole.
2. Place the outFlow Cup onto the stand and adjust the level of the stand.
3. Prepare a stopwatch with an accuracy of 0.1 seconds while holding down the outflow hole with your hand.
4. Slowly pour the measured liquid at a controlled temperature (according to the user's requirements) into the outFlow Cup to avoid bubbles, and scrape flat with a scraper or glass when the liquid exceeds the mouth of the cup.
5. Start the stopwatch and quickly release the finger holding the outflow hole at the same time, and press the stopwatch at the moment when the outflow liquid is interrupted to record the outflow time.
Calculation method:
The measured outflow time is calculated as the kinematic viscosity mm /s according to the following formula
| Cup number | ISO-3 | ISO-4 | ISO-5 | ISO-6 |
| formula | V=0.443t-200/t | V=1.37t-200/t | V=3.28t-220/t | V=6.90t-570/t |
where: v=mm² /s
t = outflow time
Centistock = K value × outflow time - (C÷ outflow time)
centipoise = centistock × specific gravity
Note: In order to obtain more accurate data, the outflow time can be measured multiple times and the average value can be calculated.
Pushen PS 1020/8 ISO Flow CupSpecifications
| LIST | VALUE |
|---|---|
| outflow time | 30~100s |
| flow hole diameter | 8mm |
| Cup height | 86mm |
| Cup width | 56mm |
| Total height | 86mm |
| Cup body material | Aluminum anodic oxidation |
| Filter material | stainless steel |
| Applicable standard | ASTM D5125、ISO 2431 |
Pushen PS 1020/8 ISO Flow Cup Packing list
Viscosity cup × 1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.