Search
    Cart(0)
      总价
      前往结算
      您的购物车是空的 : )
      Home> Coating Thickness Gauge> DongRu> DongRu DR220 (upgraded version) Coating Thickness Gauge

      DONGRU DR220 (upgraded version) Integrated Coating Thickness Gauge 0-2000μm

      The DONGRU DR220 integrated Coating Thickness Gauge is an upgraded version of the Thickness Gauge with a range of 0-2000μm. The DR220 integrated Coating Thickness Gauge adopts a larger display screen and is widely used in automotive paints, automotive evaluation, metal processing, chemical and other fields.

      Brand
      SKU: NB019670
      China DongRu
      Stock
      Loading…
      Price
      $ 226.00
      Promotion
      Service
        Service
        The delivery and service By NBchao.Com
        VS
        Genuinegoods
        • DongRu DR220 (upgraded version) Coating Thickness GaugeOverview

        • Specifications
        • Comments
        • FAQs
        DR220 (upgraded version)
        Coating Thickness Gauge

        Introduction

        The DR220 coating Thickness Gauge adopts the principle of electromagnetic induction, and according to the national industry: GB/T4956-2003 standard, it can quickly, without damage, and accurately measure the thickness of the coating on the magnetic metal surface. It can non-destructively measure the thickness of non-magnetic coatings (such as: paint, electrophoresis, enamel, rubber, powder, enamel, anti-corrosion layer, galvanized, chrome, etc.) on magnetic metal substrates (such as: steel, iron, nickel); DR220 The integrated coating Thickness Gauge is exquisite and compact, and uses a metal measuring head to make the on-site test more stable and firmer.

        This instrument can be widely used in the detection fields of automobile paint, automobile evaluation, manufacturing, metal processing, chemical industry, commodity inspection and so on.

        DR220 Coating Thickness Gauge Features

        A. Using alloy integrated probe, the world's professional technology

        B. Simple operation, fast test speed and high sensitivity

        C. Exquisite ergonomic integrated design, easy to carry

        D. Two test methods: continuous test (CONT INUE) and single (SINGLE) measurement

        E. Statistical function: maximum value (MAX), minimum value (MIN), average value (MEA)

        F. It can store 2000 measurement data (10 sets of data)

        G. It can be connected to a computer for communication and read out stored data for saving or printing (optional)

        H. Two calibration methods: zero point calibration and two point calibration

        I. There is a buzzer prompt during the operation (single measurement mode)

        I. Automatic identification of iron-based and non-ferrous-based substrates

        J. Low Voltage indication

        K. Manual/automatic shutdown function

        L, super large LCD backlight display, with screen rotation and inversion function
              M, metric and imperial conversion function um/mil


        VS

        DongRu DR220 (upgraded version) Coating Thickness GaugeSpecifications

        LIST VALUE
        Measurement principle Magnetic Induction
        Measurement range 0 ~ 2000m
        margin of error ±3%
        Resolution 0.1mm | 1mm
        Minimum radius of curvature Convex 5mm; Concave 25mm
        thinnest matrix 0.4mm
        probe F integrated probe
        Statistical function MAX Maximum (MAX), MIN Minimum (MIN), Average (MEA)
        icon function without
        Power Three (7) alkaline batteries
        Calibrated Certificate without
        Language Chinese
        Display screen LCD
        supporting software without
        Total Weight 106G (without battery)
        Complete-built unit size 126*64*28mm
        Operating temperature 0~50℃
        Minimum measurement surface 18*15mm
        Relative Humidity 20~90%RH
        operating temperature 0℃-50℃

        DongRu DR220 (upgraded version) Coating Thickness Gauge Packing list

        portable instrument bag x1, host x1, standard sheet (49, 100, 250, 370 μm) x4, iron-based x1, battery x3, cleaning cloth x1, warranty card attached to the manual x1, certificate of conformity x1.

        [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

        FAQ

        [Q]
        How to start Coating thickness gauge and start measurement?
        [A]
        Press the "ON/OFF" button, when the display appears on the LCD screen, the instrument will automatically enter the measurement state, and then press the probe vertically onto the tested coating, and the thickness value will be displayed on the display screen.
        [Q]
        What is two-point calibrating and how is it performed?
        [A]
        Two-point calibrating is to select the appropriate film thickness sheet according to the Coating thickness to be measured on the basis of zero-position calibrating, and press the probe down for measurement. If the measured value is different from the film thickness sheet, it can be corrected by the "+" "-" button.
        [Q]
        How to calibrate?
        [A]
        Zero position calibrating is done by pressing the probe against the substrate, pressing the zero correction button "ZERO" button, and then releasing it. After successful calibrating, "CAL" will be displayed on the screen and a beep will sound.
        [Q]
        Is the DR220 Coating thickness gauge suitable for outdoor use?
        [A]
        Yes, the DR220 has a sun mode that can be used in bright light and is suitable for outdoor environments.
        [Q]
        Does the DR220 support measurement of high temperature materials?
        [A]
        The DR220 standard model supports the measurement of high temperature materials up to 300 degrees, and a dedicated high temperature probe can also be selected for measurement.
        +DongRu DR220 (upgraded version) Coating Thickness Gauge Big data
          +DongRu DR220 (upgraded version) Coating Thickness GaugeSimilar products
          +DongRu DR220 (upgraded version) Coating Thickness GaugeKnowledge
          +DongRu DR220 (upgraded version) Coating Thickness GaugeStandard
          +Navigation
          DongRu
          DONGRU DR220 (upgraded version) Integrated Coating Thickness Gauge 0-2000μm
          Service
          Focus on online sales of Lab Testing Instruments