NIRUN SNB-1 Digital Viscometer with Rotor No. 21-27
Digital display, Measurement range 10~600000mPa · s, Rotor specifications 1 #, 2 #, 3 #, 4 #, 21 #, 27 #, 28 #, 29 #, Rotor speed 1~ 60rpm, reproducibility +/- 0.5% F.S, Measurement accuracy +/- 1% F.S.
NiRun-
HUINUO SNB-AIH digital display swirl/spinning high temperature Viscometer manual automatic measurement 10 million mPa · s
$ 2054.00 -
NIRUN 3000 series, standard solution (not sold separately)
$ 192.00 -
Pingxuan NDJ-8S Digital Rotational Viscometer 2000000mPa.s
$ 506.00 -
NIRUN NDJ-8ST Touch Screen Viscometer Measurement range 1-2 million mPa.s
$ 1005.00 -
TQC DV2209 viscosity calibrated oil S600 500ml
$ 431.00
Features
It can be used as a stand-alone machine or connected to a micro printer and computer for data collection.
The stepper motor rotates with high subdivision drive, the speed is accurate and stable, and the change of AC Voltage frequency does not affect the accuracy of measuring viscosity.
For thixotropic non-Newtonian liquids, the timing function of the viscometer ensures good consistent data.
The LCD has a blue backlight function, which directly displays the viscosity, rotational speed, percentmeter torque, the maximum viscosity value and temperature value that can be measured by the rotor at the current speed. The viscosity value shows a continuous variation. When the measurement range is out, there is an alarm sound.
SNB data acquisition and plotting software can be purchased for data acquisition and data analysis, and micro monochrome printers can also be purchased for timed printing of measurement results.
The full-scale range and linearity of the instrument are all calibrated through the computer interface, and its measurement performance and function have reached the same professional level abroad.
RTD temperature probe is standard to monitor the sample temperature in real time with an accuracy of 0.1°C and a temperature range of 0-100°C.
It adopts 16-bit microcomputer processor as the core, high-subdivision drive stepper motor, and digital LCD with blue backlight function.
Depending on your needs, you can choose a different standard rotor.
According to the need, the reference materials of the Bureau of Metrology can be purchased to calibrate the viscometer, so that the inspection level is in line with the international standard.
SNB data acquisition and plotting software is optional
Product Applications
SNB-1 digital viscometer is widely used in inks, glues, latexes, solvent-based adhesives, polymer solutions, petroleum, paints and coatings, solvents, cosmetics, milk products, *products, juices, etc.
Product display diagram

Optional
Ultra-low viscosity adapter (rotor size 0)
Micro printers
Dedicated viscosity thermostatic sink
SNB data acquisition and mapping software
Small sample adapter (with 21#, 27#, 28#, 29# rotors)
Standard oil
Remote control
Comparison of SNB parameters
| Model | Measuring range | Rotor speed | Measurement method |
| SNB-1 | 1-600,000 | 1-60 | Manual |
| SNB-2 | 1-6 million | 0.1-100 | |
| SNB-3 | 4-80 million | 0.1-100 | |
| SNB-AI | 1-6 million, 4-80 million | 0.1-200 | Manual, intelligent |
| Unit: mPa·s, revolutions/minute | |||
| Other parameters | |||
| Number of rotors | 4 rotors of 1, 2, 3 and 4 (rotor 0 is optional) | ||
| Measurement accuracy | ±1.0% (full scale) | ||
| repeatability | 0.50% | ||
NiRun SNB-1 (Customized) Digital ViscometerSpecifications
| LIST | VALUE |
|---|---|
| Display mode | digital explicit |
| Measurement range | 10~600000mPa·s |
| Rotor specification | 1#、2#、3#、4#、21#、27#、28#、29# |
| Rotor speed | 1~60rpm |
| reproducibility | ±0.5%F.S |
| Measurement Accuracy | ±1%F.S |
| Power supply Voltage | 110V/220V,50Hz/60Hz,DC17V1.2A |
| Weight | 7kg |
| Input Frequency | 50Hz/60Hz |
| Encasement material | Five-layer cardboard |
| collection method | continuous acquisition |
| Capacity | 300~400ml |
| Capacity | 400Ml (self-prepared) |
| Lifting system | PE lifting system |
| Bearing system | ruby |
| Torque material | beryllium bronze |
| Control system | microcomputer |
| software system | Data collection, mapping |
| temperature sensor | RID temperature sensor |
| Encasement | aluminum alloy |
| Rotation speed Control mode | Continuously variable speed (without gear drive) |
NiRun SNB-1 (Customized) Digital Viscometer Packing list
Host x1, 1 #, 2 #, 3 #, 4 #rotor X1 (set), 21 #, 27 #, 28 #, 29 #rotor X1 (set) manual x1, warranty card x1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Methods for Verifying the Accuracy of a Digital Viscometer
- Operation steps and precautions for the use of Nirun viscometer
- Sunny NDJ-5S Digital Viscometer Instructions for Use
- What are the precautions for the installation of the Fungilab Rotational Viscometer?
- Principles of Digital Viscometer Structure
- How to measure unknown viscosity samples
- How to Tell if a Digital Viscometer is Accurate
- Effect of temperature on viscosity
- The basic knowledge of viscometer is enough to read this article
- What is the difference between surface tension and Viscosity?
- ActiveASTM D3794-2022
- ActiveISO 12634-2017
- ActiveJJG 1002-2005
- ActiveGB/T 22427.7-2008
- ActiveGB/T 18856.4-2008
- ActiveSN/T 2903-2011
- ActiveGB/T 17473.5-2008
- ReplacedHG/T 3323-1982
- ActiveSY/T 0522-2008
- ActiveHG/T 3660-1999
- ActiveSY/T 5377-2007
- ActiveSY/T 0520-2008
- ActiveFZ/T 10020-2011
- ActiveJIS K5101-6-2-2004
- AbolishGB/T 2794-2013
- AbolishGB/T 2794-1995
- ISO 2884-2-2003
- ActiveGB/T 5561-2012
- ActiveJB/T 9357-1999
- ActiveGB/T 22235-2008


SNB-1 (Customized)