LIULING CH-10-A φ 10mm upper probe, 100% hand rubber thickness gauge 0~ 10mm
LIULING CH-10-A φ 10mm upper probe percentile hand rubber thickness gauge is used to test rubber, plastics and other Film thickness, suitable for workshop site measurement, CH-10-A hand rubber thickness gauge measurement Film thickness range 0~ 10mm, pointer indication.
LiuLing-
LIULING CH-10-C Wire and cable thickness gauge 0~ 10mm
$ 304.00 -
WBT-02 Bottle Wall Film thickness Tester, digital display, bottle, box
$ 637.00 -
LIULING CH-20-AT Percent Benchtop Rubber Thickness Gauge 0mm~ 20mm
$ 296.00 -
LIULING CH-20Ø 4 Upper Probe 10kPa, 22kPa Digital Display Desktop Thousand-decimal Special Thickness Gauge
$ 692.00 -
LIULING CH-1-B Latex Thickness Gauge 0~ 1mm
$ 242.00
Introduction
This Thickness Gauge is an instrument for measuring the thickness of rubber and plastic products. It refers to the implementation of HG/T 2041-2009 "Technical Conditions for Rubber Thickness Gauge", HG/T 2198-2011 "General Requirements for Physical Test Methods of Vulcanized Rubber" and HG/T T 2382—1992 "General Technical Conditions for Rubber Testing Instruments and Equipment" and other industry standards of the Ministry of Chemical Industry. It has the characteristics of simple structure, convenient use and reliable quality. The large-span Thickness Gauge with a measuring depth of 130mm has only one specification of hand type. Easy to carry, hand-held measurement, suitable for on-site measurement in the workshop.

LiuLing CH-10-A φ 10mm upper probe Percent hand rubber thickness gaugeSpecifications
| LIST | VALUE |
|---|---|
| Measurement range | 0~10mm |
| Measurement accuracy | ≤0.02mm |
| reading display | Pointer |
| Graduation | 0.01mm |
| Pressure and mass required | 22kPa ± 5kPa (176g ± 20g) |
| upper probe diameter | & 10Mm flat |
| Probe center to maximum measurement depth | 130mm |
| Meet the standard | HG/T 2041-2009 |
LiuLing CH-10-A φ 10mm upper probe Percent hand rubber thickness gauge Packing list
host X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveGB/T 3830-2024
- ActiveJJF 1488-2014
- ActiveHG/T 2041-2009
- ActiveGB/T 14831-2003
- ActiveJJG (轻工)50.3-2000
- ActiveJJG (轻工)50.2-2000
- ActiveASTM F2251-2023
- ActiveQB/T 1055-2004
- ActiveGB/T 7125-2014
- AbolishHG/T 2041-1991


CH-10-A φ 10mm upper probe