LEICI PF-2-01 Fluorine ion electrode range 10-1~ 5 × 10-6
Measurement range of LEICI PF-2-01 fluorine ion electrode is 10-1~ 5 × 10-6, Temperature range is 5~ 45 ℃, PF-2-01 fluorine ion electrode shell is plastic, using BNC connector.
LeiCi-
BANTE E202-BNC planar pH electrode for measurement of semi-solid samples
$ 102.00 -
HANNA HI7004L pH standard solution calibrated value: 4.01pH (25 ℃)
$ 116.00 -
YueFeng PHB-4 Portable Acidity Meter 0~14.0pH
$ 192.00 -
KODIDA CT-6821 Industrial pHmeter ORP
$ 127.00 -
HANNA HI7061L Universal electrode cleaning solution 500mL
$ 119.00
Introduction
Ion-selective electrode is an electrochemical sensitive element with a linear relationship between the potential and the logarithm of ion activity in a given solution, and is a kind of electrochemical sensor that uses membrane potential to determine ion activity or concentration in a solution, and its core component is the induction membrane at the tip of the electrode.
Ion-selective electrode method is a branch of potentiometric analysis, which is generally used for direct potentiometric method and can also be used for potentiometric titration.
Features
It can determine the concentration of specific ions in solution, has a wide range of applications, and is not affected by reagent color, turbidity, etc.
Applications
Ion-selective electrodes can be analyzed in a wide range of objects, as long as the correct ion measurement method is selected,
The Ion Meter and electrode can then measure the concentration of the corresponding ion. It has been successfully used in environmental testing, water quality monitoring, soil analysis, food testing, analysis and other fields.

LeiCi PF-2-01 Fluorine ion electrodeSpecifications
| LIST | VALUE |
|---|---|
| Measurement range | (10 -1-10 -6)mol/L |
| sensitive film | single crystal |
| shell material | Organic Glass |
| Dimension | Φ12×120mm |
| Temperature range | 5-45℃ |
| Connector | BNC (Q9 type) |
LeiCi PF-2-01 Fluorine ion electrode Packing list
Electrode X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveJJG 2060-2014
- ActiveJJF 919-2023
- ActiveSN/T 5051-2018
- ActiveHG/T 2797.4-2007
- ActiveHJ 955-2018
- ActiveGB/T 6920-1986
- ActiveGB/T 9724-2007
- ActiveGB/T 22592-2008
- ActiveGB/T 2390-2013
- ActiveGB/T 14518-1993
- ActiveISO 19396-2-2017
- ActiveISO 19396-1-2017
- ActiveGB/T 6368-2008
- ActiveGB 8325-1987
- ActiveGB/T 13531.1-2008
- ActiveGB/T 11165-2005
- ActiveQB/T 2724-2005
- ActiveJB/T 6858-1993
- ActiveHG/T 4164-2010
- ActiveQB/T 4103-2010


PF-2-01