LEICI JPBJ-608 Portable Dissolved Oxygen Meter
LEICI JPBJ-608 portable Dissolved Oxygen Meter measurement dissolved oxygen range of 0.00~19.99mg/L, support zero oxygen and full calibrate, JPBJ-608 Dissolved Oxygen Meter with LCD screen, can simultaneously measure a variety of parameter values.
LeiCi-
HANNA HI97701 Portable residual chlorine photometer
$ 529.00 -
NOBOTECH DO-6800 Industrial Online Dissolved Oxygen Meter
$ 363.00 -
LEICI Ammonia Gas sensing electrode calibrated solution for Ammonia Gas sensing electrode
$ 106.00 -
HANNA HI2004 Desktop saturated Dissolved Oxygen Meter
$ 1111.00 -
JINGQI WD8801 residual chlorine analyzer
$ 481.00
Features
● High-definition LCD screen is used to display clearly
● Temperature units are optional: °C and °F.
● Support self-diagnosis, automatic shutdown, power-off protection and factory reset functions
● Support firmware upgrade function, allowing function expansion and personalized requirements
● Support IP65 protection level
● Equipped with polarographic dissolved oxygen electrode, electrode hanger, silicone protective case, wrist strap, and portable carrying case as standard
Intelligent detection and automatic identification
● Intelligent endpoint discrimination, support automatic reading, timed reading, timed interval reading, and manual reading
● Support automatic temperature compensation, automatic atmospheric pressure compensation (kPa, mmHg, atm and other units are optional)
● Automatic zero oxygen calibration and full calibration
● Support manual salinity compensation
Data management, information traceability
● Support data storage (500 sets each), view, delete, transfer and print
● Comply with GLP and realize data traceability
● Support connection to standard RS-232 serial printer, directly print measurement results, printing format optional
● It has a USB interface, which can be connected with a PC through a dedicated communication software to realize data transmission
power management
● Powered by large-capacity lithium battery, it supports charging by connecting PC and power bank
● It has the function of battery under-Voltage reminder and charging status reminder
● Support backlight adjustment
LeiCi JPBJ-608 Portable Dissolved Oxygen Meter (1 meter)Specifications
| LIST | VALUE |
|---|---|
| DO range | 0.00~50.00mg/L |
| Resolution | 0.01 mg/L |
| Electronic unit error of indication | ±0.10mg/L |
| An indication of instrument error | ≤20.00mg/L:±0.30 mg/L >20.00mg/L:±10.0% |
| Response time | ≤ 45s (90% Response at 20 ℃) |
| Salinity compensation error | ±2% |
| DO% Measurement range | 0.0~300.0% |
| Resolution | 0.10% |
| Electronic unit error of indication | ±2.0% |
| An indication of instrument error | ±10.0% |
| Measurement range | -5.0~110.0℃ |
| Resolution | 0.1℃/0.1℉ |
| Electronic unit error of indication | ±0.2 ℃ |
| An indication of instrument error | +/- 0.4 ℃ (0.0 ℃ -60.0 ℃); +/- 1.0 ℃ (Miscellaneous range) |
| Power Supply | Rechargeable lithium battery, power adapter (input: AC100~240V, output: DC5V) |
| Dimensions | 80*225*35mm |
| Weight | 0.4kg |
LeiCi JPBJ-608 Portable Dissolved Oxygen Meter (1 meter) Packing list
Host X1, DO-958-BF type dissolved Oxygen electrode X1, manual x1, certificate x1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- The correct operation method of the dissolved Oxygen Meter [including five-minute video demonstration]
- Water quality, water treatment method and explanation of water treatment terms
- Introduction to STIP-scan function and principle
- The principle and main functions of STIP-scan
- Application value of dissolved oxygen Detector in brewery
- What type of electrode can be used to measure dissolved oxygen?
- Electrochemistry Corrosion and Its Influencing Factors
- How to choose the dissolved oxygen measurement method: optical method, current method, polarographic method?
- Introduction to anti-corrosion mechanism of coating
- Influence of metal surface cleaning methods on test results
- ActiveJJF 1714-2018
- ActiveJJF 1565-2016
- ActiveJJF 1441-2013
- ActiveJJG 2104-2024
- ActiveHJ 925-2017
- Active 096-2007
- ActiveSC/T 7006-2001
- AbolishGB/T 12157-2007
- ActiveGB/T 20245.4-2013
- ActiveGB/T 12157-2022
- ActiveGB/T 1576-2018
- ActiveHJ 2515-2012


JPBJ-608