JINGTIAN LVDV-1 digital display Rotational Viscometer 6 million mPa·s 99.9rpm
JINGTIAN LVDV-1 digital display Rotational Viscometer adopts backlit LCD display, measurement Viscosity range 12~ 6000000mPa·s, LVDV-1 Rotational Viscometer standard L1, L2, L3, L4 rotor, accuracy of ± 1% FS.
JingTian-
NIRUN NTV-CAP1HB Cone-plate Viscometer Low shear rate, rotor required separately
$ 8591.00 -
MODERNER NDJ-5S Digital Rotational Viscometer viscosity range: 1~ 100000mPa · s
Login -
NIRUN SNB-2 Digital Rotational Viscometer Measurement range 10~6 million mPa · s
$ 1462.00 -
NIRUN NTV-P2RV touch screen Rotational Viscometer Rotor Viscosity-Meter 40M mPa · s
$ 3938.00 -
NIRUN DV-79B Digital Viscometer Medium and High Viscosity
$ 1987.00
Introduction
The LCD of Shanghai JINGTIAN LVDV-1 digital display rotary viscometer can display viscosity, shear rate, shear stress, rotational speed, temperature, percentile torque, rotor number and the maximum measurable value of the selected rotor at the current rotational speed. Viscosity value etc. It is a digital display rotary viscometer with a measuring range of 12 to 6,000,000 mPa·s.

JingTian LVDV-1 Digital Rotational ViscometerSpecifications
| LIST | VALUE |
|---|---|
| Display | digital display |
| Measuring range | 12~6000000mPa·s |
| Rotor Specifications | L1#、L2#、L3#、L4# |
| Reproducibility | ±0.5%F.S |
| Measurement Accuracy | ±1% |
| Power | Dedicated power adapter (input 100~240V 50~60Hz) |
| Rotor speed | 0.1~99.9rpm |
| Display information | Viscosity, rotational speed, temperature, percentile torque, rotor number and the maximum Viscosity value that can be measured at the current rotational speed of the selected rotor, etc |
| Speed control method | CVT |
JingTian LVDV-1 Digital Rotational Viscometer Packing list
Host X1, protection frame X1, rotor X1 (sleeve), base and horizontal adjustment bolt X1, lifting frame and lifting mechanism X1, special power adapter X1, wrench X1, RTD temperature probe X1, RS232 standard output interface X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveHG/T 4443-2012
- ActiveHG/T 3323-2008
- ActiveGB/T 21059-2007
- ActiveGB/T 13217.4-2020
- ActiveHG/T 3948-2007
- ActiveASTM D3794-2022
- ActiveISO 12634-2017
- ActiveJJG 1002-2005
- ActiveGB/T 22427.7-2008
- ActiveMH/T 6062-2010
- ActiveGB/T 18856.4-2008
- ActiveSN/T 2903-2011
- ActiveGB/T 17473.5-2008
- ReplacedHG/T 3323-1982
- ActiveSY/T 0522-2008
- ActiveHG/T 3660-1999
- ActiveGB/T 21882-2008
- AbolishGB/T 11175-2002
- ActiveSY/T 5377-2007
- ActiveSY/T 0520-2008


LVDV-1





