JINGTIAN RVDV-2 digital display Rotational Viscometer 40 million mPa·s 200rpm
Fine digital display Rotational Viscometer RVDV-2 measurement Viscosity range 40~40000000mPa·s, is a liquid crystal display Viscosity Measurement Instrument, used for Coating paint and other Viscosity tests, RVDV-2 measurement accuracy of ± 1%.
JingTian-
JINGHAI DV-E Laboratory Rotational Viscometer 1-200,000mPa · s
$ 1859.00 -
FANGRUI RTD temperature probe, temperature range 0~100 ℃ optional accessories
$ 132.00 -
NIRUN NDJ-8S Digital Viscometer swirl/spin Viscosity meter 2 million CP new
$ 951.00 -
HUINUO SNB-2 digital Rotational Viscometer 6 million CP printer
$ 1166.00 -
Shangtian Jingyi NDJ-1 NDJ Pointer Viscometer Dial Viscosity meter 1X10 mPa · s
$ 432.00
Introduction
The LCD of Shanghai JINGTIAN RVDV-2 digital display rotary viscometer can display viscosity, shear rate, shear stress, rotational speed, temperature, percentile torque, rotor number and the maximum measurable value of the selected rotor at the current rotational speed. Viscosity value etc. It is a digital display Rotational Viscometer with a range of 40 to 40,000,000 mPa·s.

Dimensions


JingTian RVDV-2 Digital Rotational ViscoMeterSpecifications
| LIST | VALUE |
|---|---|
| Display | digital display |
| Measuring range | 40~40000000mPa·s |
| Rotor Specifications | R2#、 R3#、R4#、R5#、R6#、R7# |
| Reproducibility | ±0.5%F.S |
| Measurement Accuracy | ±1% |
| Power | Dedicated power adapter (input 100~240V 50~60Hz) |
| Rotor speed | 0.1~200rpm |
| Display information | Viscosity, shear rate, shear stress, rotational speed, temperature, percentile torque, rotor number and the maximum Viscosity value that can be measured at the current rotational speed of the selected rotor, etc |
| Speed control method | CVT |
JingTian RVDV-2 Digital Rotational ViscoMeter Packing list
Host X1, protection frame X1, rotor X1 (sleeve), base and horizontal adjustment bolt X1, lifting frame and lifting mechanism X1, special power adapter X1, wrench X1, RTD temperature probe X1, RS232 standard output interface X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveHG/T 4443-2012
- ActiveHG/T 3323-2008
- ActiveISO 19613-2018
- ActiveGB/T 21059-2007
- ActiveGB/T 13217.4-2020
- ActiveHG/T 3948-2007
- ActiveASTM D3794-2022
- ActiveISO 12634-2017
- ActiveJJG 1002-2005
- ActiveGB/T 22427.7-2008
- ActiveGB/T 18856.4-2008
- ActiveSN/T 2903-2011
- ActiveGB/T 17473.5-2008
- ReplacedHG/T 3323-1982
- ActiveSY/T 0522-2008
- ActiveHG/T 3660-1999
- ActiveGB/T 21882-2008
- AbolishGB/T 11175-2002
- ActiveSY/T 5377-2007
- ActiveSY/T 0520-2008


RVDV-2