JINGTIAN RVDV-1H High temperature Rotational Viscometer 10 million mPa·s 250 ℃
JINGTIAN RVDV-1H high temperature Rotational Viscometer adopts embedded integral heating, with blue LCD, RVDV-1H high temperature Rotational Viscometer Measurement range is 100~10000000mPa·s, reproduction accuracy is +/- 0.5%.
-
HUINUO NDJ-1S Digital Rotational Viscometer with L0 rotor
$ 518.00 -
NIRUN LDV-1 + Pro Digital Viscometer Measurement range 10~2 million cP
$ 2225.00 -
HUINUO LVDV-2 Digital Rotational Viscometer with L0 rotor
$ 1566.00 -
RVDV-1H High temperature Rotational Viscometer 10 million mPa · s 250 ℃
$ 2061.00 -
NIRUN NTV-T3R Viscosity and Temperature Control Integrated Machine 10 million cp Suitable for molten materials
$ 4276.00
Introduction
It mainly measures substances that are solid at room temperature and become liquid after heating at high temperature, such as asphalt, hot melt adhesive, polyethylene wax, etc.
It can be used as a stand-alone machine, and the measurement data can be directly displayed on the LCD without secondary calculations; it can also be equipped with "data collection analysis and drawing software" to realize data collection and data analysis, and monitor the viscosity-temperature curve throughout the process.
Using high-resolution stepping motor, the speed is accurate and stable.
LCD liquid crystal with blue backlight function, directly display viscosity, speed, percent torque, rotor number, and the maximum viscosity value and temperature value that can be measured at the current speed of the selected rotor. DV-2 series can also display shear rate and shear stress. The viscosity value shows a continuous change, and there will be an alarm sound when it exceeds the measurement range.
The measurement performance of the instrument has reached the level of foreign products of the same type through computer correction.
The high-temperature furnace adopts built-in overall heating, which is evenly heated and has small thermal inertia.
Instrument structure

DV-H series selection
| model | LVDV-1H | RVDV-1H | HBDV-1H | LVDV-2H | RVDV-2H | HBDV-2H |
| Measuring range | 10~1M | 100~10M | 800~80M | 5~1M | 50~10M | 400~80M |
| (mPa·s) | ||||||
| spinning speed | 0.1~99.9 stepless speed change | 0.1~200 stepless speed change | ||||
| (rev/min) | ||||||
| Rotor configuration | No. 21, No. 27, No. 28, No. 29 rotors each 1 piece | |||||
| measurement accuracy | ±1% (FS) Newtonian fluid | |||||
| Reproducibility | ±0.5% (FS) Newtonian fluid | |||||
| Sample volume (mL) | 10~20 | |||||
| Temperature control range (℃) | Room temperature +10~250 | |||||
| Temperature control accuracy (℃) | ±0.1 | |||||
| power supply | 220V 50Hz | |||||
JingTian RVDV-1H Digital Rotational ViscometerSpecifications
| LIST | VALUE |
|---|---|
| Display mode | digital |
| Measurement range | 100~10000000mPa·s |
| Rotor specification | 21#、 27#、28#、29# |
| Reproducibility | ±0.5%F.S |
| Measurement Accuracy | ±1%F.S |
| Power | 220V 50Hz |
| Rotor speed | 0.1~99.9rpm |
| Display information | Viscometer: Viscosity, Rotation speed, Temperature, Percentimeter torque, Rotor number and the maximum viscosity value of the selected rotor at the current Rotation speed. Temperature Controller: Set temperature and actual Measuring temperature display. |
| Capacity | 10~20mL |
| Temperature range | RT+10~250℃ |
| Temperature Accuracy | ±0.1℃ |
| Rotation speed Control mode | Continuously variable speed |
JingTian RVDV-1H Digital Rotational Viscometer Packing list
Viscometer host X1, bracket X1, measuringflask X1, rotor X1 (sleeve), base and horizontal adjustment foot X1, temperature controller X1, insulation cover X1, positioning frame X1, power cord X1, lifting frame and lifting mechanism X1, special power adapter X1, wrench X1, RTD temperature sensor X1, heating furnace X1, special forceps pliers X1, connecting cable X1, connecting hook X2
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveGB/T 8884-2017
- Active 0739-2014
- ActiveJC/T 2678-2022
- ActiveGB/T 22427.7-2023
- ActiveSN/T 0739-2003
- ActiveGB/T 21059-2007
- ActiveGB/T 13217.4-2020
- ActiveHG/T 3948-2007
- ActiveJJG 1002-2005
- ActiveGB/T 22427.7-2008
- ActiveGB/T 18856.4-2008
- ActiveSN/T 2903-2011
- ReplacedHG/T 3323-1982
- ActiveSY/T 0522-2008
- ActiveGB/T 21882-2008
- ActiveSY/T 5377-2007
- ActiveSY/T 0520-2008
- AbolishGB/T 2794-2013
- ActiveGB/T 14490-2008