      Home> Coating Thickness Gauge> DongRu> DongRu DR230 Coating Thickness Gauge

      DONGRU DR230 Coating Thickness Gauge can automatically identify ferrous or non-ferrous substrate Film Thickness Gauge

      Magnetic Induction and eddy Current thickness measurement, automatic substrate identification, thickness range 0~1000μm, error accuracy +/- 3%, built-in F and NF probes, thinnest substrate 0.4mm, support zero and two point calibrate.

      Brand
      SKU: NB000208
      China DongRu
      Model
      Stock
      Loading…
      Price
      $ 285.00
      Promotion
      Service
        Service
        The delivery and service By NBchao.Com
        VS
        Genuinegoods
        • DongRu DR230 Coating Thickness GaugeOverview

        • Specifications
        • Comments
        • FAQs
        DR230
        Coating Thickness Gauge
        • DONGRU DR230 Coating Thickness Gauge can automatically identify ferrous or non-ferrous substrate Film Thickness Gauge
        • DONGRU DR230 Coating Thickness Gauge can automatically identify ferrous or non-ferrous substrate Film Thickness Gauge Figure 1
        • DONGRU DR230 Coating Thickness Gauge can automatically identify ferrous or non-ferrous substrate Film Thickness Gauge Figure 2
        Magnetic Induction and eddy Current thickness measurement, automatic substrate identification, thickness range 0~1000μm, error accuracy +/- 3%, built-in F and NF probes, thinnest substrate 0.4mm, support zero and two point calibrate.

        Coating Thickness Gauge Selection Tool

        Product Description

        Dongru DR230 coating Thickness Gauge has the same shape and structure as DR210 and DR220, and it is also an integrated structure with a built-in probe. However, the DR230 coating Thickness Gauge is an eddy current/magnetic induction dual-purpose coating Thickness Gauge, which can automatically identify ferrous or non-ferrous substrates. The DR230 coating Thickness Gauge has a data storage function, and can perform two calibration methods, zero point and two point. It will automatically shut down if it is not operated within a certain period of time. Although it is small in size, it has powerful functions. DR230 coating Thickness Gauge can be widely used in manufacturing, metal processing, chemical industry, commodity inspection and other fields, with integrated design, easy to carry and accurate measurement.

        Special feature

        DR230 coating Thickness Gauge can automatically identify the base material.

        Magnetic Thickness Measurement Method

        It can non-destructively measure the thickness of non-magnetic coatings (such as: galvanized, chrome, paint, electrophoresis, enamel, rubber, powder, enamel, anti-corrosion layer, plastic spraying, etc.) on magnetic metal substrates (such as: steel, iron, nickel) )

        Eddy Current Thickness Measurement Method

        Non-destructively measure the thickness of non-conductive coatings (such as: paint, powder, plastic, rubber, enamel, enamel, anti-corrosion coating, etc.) on non-magnetic metal substrates (such as: aluminum, copper, stainless steel)

        DR230 Coating Thickness Gauge is an all-in-one Thickness Gauge, which integrates the features of portable, all-in-one, hand-held, intelligent digital display, etc. It can automatically identify the substrate and substrate, and measure the coating thickness of the metal surface quickly and without damage. Measurement.

        Features

        Small and integrated design, easy to carry

        Simple operation and fast test speed

        DR230 coating Thickness Gauge can store 116 measurement data

        It can be connected to a computer for communication and read out stored data for saving or printing

        Two calibration methods: zero point calibration and two point calibration

        There is a buzzer prompt during the operation (single measurement mode)

        Automatic identification of ferrous and non-ferrous substrates

        DR230 coating Thickness Gauge has low Voltage indication function

        Manual/automatic shutdown function

        Two test methods: continuous test (CONT INUE) and single (SINGLE) measurement

        Four statistical functions: maximum value (MAX), minimum value (MIN), average value (MEA), measurement times

        Calibration method

        1. Zero calibration.

        Put the probe of the DR230 coating thickness gauge vertically on the substrate, press and hold the zero calibration key "ZER0", and then release it until the display shows "CAL" before lifting the probe, otherwise the zero calibration will fail.

        2. Two-point calibration

        1) Calibrate the zero position first.

        2) According to the measurement coating thickness requirements of the experiment, select the closest diaphragm and place the diaphragm on the calibration substrate, then lower the probe to measure. If the measured value is different from the diaphragm, lift the probe and use the "+" and "-" buttons to correct.


        VS

        DongRu DR230 Coating Thickness GaugeSpecifications

        LIST VALUE
        Measurement principle Magnetic Induction + eddy Current
        Measurement range 0 ~ 1000µm
        margin of error ±3%
        Resolution 0.1mm | 1mm
        Minimum radius of curvature Convex 5mm; Concave 25mm
        thinnest matrix 0.4mm
        probe F and NF integrated probes
        Statistical function Average, MAX Maximum, MIN Minimum, Number of Tests
        icon function without
        Power 2 * AA alkaline battery
        Calibrated Certificate without
        Language Chinese
        Display screen LCD
        supporting software without
        Total Weight 99g
        Complete-built unit size 102*62*27mm
        Operating temperature 0~50℃
        Minimum measurement surface 10*10mm
        Relative Humidity 20~90%RH

        DongRu DR230 Coating Thickness Gauge Packing list

        instrument case x1, host x1, standard piece x4, iron-based x1, aluminum-based x1, battery x2, cleaning cloth x1, warranty card x1 attached to the manual, certificate x1.

        [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

        FAQ

        [Q]
        Can I test the pipeline anti-corrosion layer?
        [A]
        Magnetic induction can be measured, but the film thickness of the anti-corrosion layer should be considered. If it exceeds the range, it is recommended to buy a special model for the anti-corrosion layer.
        [Q]
        Does the DONGRU Coating thickness gauge meet the ASTMB499 standard?
        [A]
        Coating thickness gauge of the DR230 can refer to
        +DongRu DR230 Coating Thickness Gauge Big data
          +DongRu DR230 Coating Thickness GaugeSimilar products
          +DongRu DR230 Coating Thickness GaugeKnowledge
          +DongRu DR230 Coating Thickness GaugeStandard
          +Navigation
          DongRu
          DONGRU DR230 Coating Thickness Gauge can automatically identify ferrous or non-ferrous substrate Film Thickness Gauge
          Service
          Focus on online sales of Lab Testing Instruments