HANNA HI8720 oxidation reduction ORP monitoring and analysis controller
HANNA HI8720 oxidation reduction ORP monitoring and analysis controller is a real ORP controller, Measurement range of +/- 1000mV, HI8720 oxidation reduction ORP monitoring and analysis controller with large LCD display and background light.
HANNA-
HANNA HI98302 High Range Total Solid solubility TDS
$ 186.00 -
LEICI 780800N03 Residual chlorine/chlorine dioxide kit for DGB-403F
$ 117.00 -
Bante810 laboratory Dissolved Oxygen Meter
$ 392.00 -
Bante70 portable intelligent multiparameter instrument STIP-scan pH ORP Ion concentration conductivity TDS salinity resistivity
$ 716.00 -
LEICI Fluorine Boricacid electrode calibrated solution, suitable for fluorine Boricacid electrode
$ 106.00
Introduction
It is a compact panel-mounted online continuous detection redox [ORP] controller, measuring range: ±1000mV
Equipped with a large LCD display with protective cover and backlight, single set point, single output for oxidation or reduction dosing settings, manual two-point calibration through the panel, analog output: 0 to 20 mA or 4 to 20 mA [ isolationã
Manual ON, OFF and automatic quantitative control can be selected for oxidation or reduction quantitative dosing settings; the automatic diagnostic function can verify offset and slope calibration as well as electrode contamination or failure, and the fail-safe alarm system can prevent power failure or signal interruption. and caused problems.

HANNA HI8720 Oxidation reduction ORP monitoring and analysis controllerSpecifications
| LIST | VALUE |
|---|---|
| Measurement range mV | ±1000mV |
| pH resolution | 1mV |
| Measurement Accuracy of mV | +/- 5mV, +/- 0.5% (input mode) |
| pH calibrating mode | Drift: CAL knob manual trimmer +/- 200mV |
| Impedance -pH | 10 ^ 12Ohm, electrode type with matching reference pin input can be used, 4 to 20 mA |
| pH electrode type | BNC Interface type, according to the requirements of the measurement project, select the BNC type acidity pH electrode |
| Dosing relay set point | 1, maximum 2A (isolated), 240 VAC |
| Dosing relay setting range | ±1000mV |
| Alarm relay set point | 1, maximum 2A (isolated), 240 VAC |
| Alarm relay setting range | 10~300 mV |
| Dosing control mode | Manual selector switch OFF/AUTO/ON |
| control delay time | Manual front panel knob adjustment within 5 to 60 minutes, this function can be turned off through the rear panel terminal |
| analog output | 0 to 20 mA or 4 to 20 mA [Isolated] |
| Backlight Settings | Keep on |
| opening size | 141 * 69Mm, depth: 135mm |
| Power Supply | 230AC ± 10%,50/60 Hz |
| Applicable environment | -10~50 ℃; 95% RH, non-condensing |
| Shell material | ABS flame retardant plastic housing and panel design, equipped with a high transparent splash-proof front cover |
| Dimensions | 141*69mm |
| Weight | 1kg |
HANNA HI8720 Oxidation reduction ORP monitoring and analysis controller Packing list
machine X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.


HI8720