Qiwei WGZ-XT Bacterial Turbidity Meter 0~6MCF
Qiwei WGZ-XT bacterial Turbidimeter was used to test the bacterial concentration in the suspension of the strains to be identified. It was calibrated with McLean's turbidity standard solution, and the WGZ-XT bacterial Turbidimeter was measuring range from 0 to 6MCF.
QiWei-
JINGQI WGZ-400B Portable precision low turbidity instrument
$ 481.00 -
Yuefeng SGZ-800IT Microcomputer Turbidity Meter 800NTU/0.001
$ 599.00 -
Qiwei WGZ-500AS Microcomputer Turbidity Meter 0~500NTU
$ 257.00 -
Yuefeng SGZ-400A Turbidity Meter 0~400NTU/0.01
$ 405.00 -
NOBOTECH ZS-600 Flow type online Turbidimeter 0-500NTU
$ 752.00
Introduction
WGZ-XT Bacterial Turbidimeter is mainly used to determine the concentration of bacteria in the suspension of strains to be identified. The instrument is calibrated with (BaSO4) McFarland turbidity standard solution, using MCF (McFarland) McFarland turbidity unit. Directly display the McFarland unit turbidity value. It is suitable for the determination of bacterial liquid concentration in medical and health units, biological products, quarantine institutions and scientific research institutions.
Instrument principle
The basic principle of this instrument is that after the measuring device is placed in the sample, the light beam emitted by the light source forms scattered light when encountering bacterial particles, and the McFarland turbidity signal of the 90° scattered light generated thereby is received by the photosensitive element, and the light signal After circuit amplification and single-chip microcomputer data processing, the measured McFarland turbidity value is displayed.
Key Description
Calibration key: enter the calibration state and perform zero calibration on the blank value
Confirm key: confirm the previous operation
Storage key: save the measured value
Query key: query saved measured values
Features
1. Microcomputer, touch keyboard, LCD backlit liquid crystal display, make reading more comfortable, and not affected by natural light
2. Quickly set the average measurement mode to get correct data in the shortest time. .
3. Simple operation, appropriate measurement range and high cost performance, more suitable for use in various industries.
4. The unique positioning structure and high-precision optical path system can effectively ensure the correctness and repeatability of the measured values.
5. The circuit system with low drift, high precision and good stability, and effective long-life light source can effectively ensure the stable operation of the instrument for a long time
6. Can store 20 historical records, no loss when power off
Operating Conditions
1. The instrument should be placed in a dry room at a temperature of 5°C-35°C.
2. When in use, it should be placed on a flat work surface and avoid vibration.
3. The indoor lighting should not be too strong, and avoid direct sunlight.
4. Try to stay away from high-intensity magnetic fields, electric fields and electrical equipment that generate high-frequency waves.
5. Avoid high temperature close to the instrument.
6. Power supply to the instrument: 220V±22V, 50±1Hz, and a good grounding wire is required.
QiWei WGZ-XT Bacterial Turbidity MeterSpecifications
| LIST | VALUE |
|---|---|
| Measurement principle | 0.001 MCF |
| resolution | 0~6MCF (McDonnell Turbidity Unit) 1MCF = 3 × 108CFU/ml |
| Error of indication | ±6%(±5%F.S) |
| Sexual repeability | ±0.5%F.S |
| Zero drift | ±0.5%F.S |
QiWei WGZ-XT Bacterial Turbidity Meter Packing list
Turbidity meter host 1, power cord 1, sample bottle 3, manual, certificate of conformity, warranty card
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.