DONGRU DR270 Coating Thickness Gauge adopts eddy current thickness measurement principle nondestructive measurement nonmagnetic metal matrix
EDDY Current Coating Thickness Gauge, thickness range 0~1250μm, accuracy of +/- 3%, thinnest substrate 0.4mm, split NF probe, can store more than 800 measurement data, two and zero point calibrated.
DongRu-
QNix 9500Pro Coating Thickness Gauge
$ 1226.00 -
LANDTEK CM8829Fn Coating Thickness Gauge, integrated paints Thickness Gauge Film Thickness Gauge
$ 386.00 -
Leeb242 (N1) Coating Thickness Gauge can print measurement data
Login -
LEEB Probe N1 eddy Current Probe with leeb242 Coating Thickness Gauge
Login -
Defelsko F90S split 90 ° right angle probe measurement low headroom area
$ 1017.00
Product Description
Dongru DR270 coating Thickness Gauge is a digital display eddy current Thickness Gauge without a built-in probe. It is easy to measure the thickness of the coating surface of the measured object at a long distance by connecting the probe and the thickness measuring host through a connecting line. The sensitivity of the probe High, and use high-quality components to ensure the stability and accuracy of the measurement. The DR270 coating Thickness Gauge has a data storage function and can be connected to a printer to print measurement data, which is convenient for subsequent data management.
Dongru DR270 coating Thickness Gauge adopts the principle of eddy current thickness measurement to realize non-destructive measurement of non-magnetic metal substrates, such as non-conductive coating thickness on aluminum, copper, and stainless steel. Widely used in paint, powder, rubber, electrophoresis, anti-corrosion layer, enamel, enamel, etc.
Features
Simple operation, fast test speed, good sensitivity and high measurement accuracy
Large capacity storage, can store more than 800 measurement data
Various testing methods:
Continuous (CONT INUE) and single (SINGLE) measurement methods
There are four statistical functions:
Maximum value (MAX), minimum value (MIN), average value (MEA), measurement times (No)
Provide intelligent operation process:
The operation process is marked with a buzzer (single measurement mode)
Automatic identification of ferrous and non-ferrous substrates
Metric and imperial conversion μm/Mil
Large screen display, backlight display mode, low Voltage indication
Manual/automatic shutdown function
Connect to a computer for communication, read out stored data for saving or printing (applicable to U-type host)
Two calibration methods are available:
Zero-point calibration and two-point calibration
Instructions for use
1) After the DR270 coating Thickness Gauge is installed with the battery, press the "ON/OFF" button to turn it on, and after the buzzer sounds, the LCD will display "0".
2) The DR270 coating Thickness Gauge automatically enters the measurement state, and directly presses the probe vertically and quickly onto the coating on the surface of the workpiece.
3) The DR270 coating Thickness Gauge automatically measures the coating thickness through the probe, and displays the thickness value on the display screen (note: keep the probe vertical when measuring)
Maintenance
1. Storage temperature of DR270 coating Thickness Gauge: 0℃~40℃, Relative Humidity ≤85%.
2. When the DR270 coating Thickness Gauge is not in use, the battery should be taken out, and the probe and diaphragm should be cleaned regularly.
3. Keep away from strong electromagnetic fields, oil, heavy dust, and humid places, and prevent collisions as a precision instrument.
DongRu DR270 Coating Thickness GaugeSpecifications
| LIST | VALUE |
|---|---|
| Measurement principle | Eddy Current |
| Measurement range | 0 ~ 1250µm |
| margin of error | ±3% |
| Resolution | 0.1mm | 1mm |
| Minimum radius of curvature | Convex 5mm; Concave 25mm |
| thinnest matrix | 0.4mm |
| probe | NF Split Probe |
| Statistical function | Average, MAX Maximum, MIN Minimum, Number of Tests |
| icon function | without |
| Power | 3 * AAA alkaline battery |
| Calibrated Certificate | without |
| Language | Chinese |
| Display screen | LCD |
| supporting software | without |
| Total Weight | 100g |
| Complete-built unit size | 130*70*24mm |
| Operating temperature | 0~50℃ |
| Minimum measurement surface | 10*10mm |
| Relative Humidity | 20~90%RH |
DongRu DR270 Coating Thickness Gauge Packing list
host x1, standard sheet x1, aluminum substrate x1, battery x3, manual x1, certificate x1, cleaning cloth x1.
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Coating thickness detection method overview
- Introduction of nondestructive thickness testing principle and instrument
- Correct use of Film Thickness Gauge
- Test method for film thickness
- Application Value of Coating Thickness Gauge in Steel Structure Coating Construction
- How to choose a Thickness Gauge?
- Film Film thickness determination
- Introduction of wet film thickness measuring instrument
- Choice of Coatings
- Principle, Application and Type Selection Analysis of Chrome Coating Thickness Gauge
- ActiveGB/T 44757-2024
- ActiveJB/T 13939-2020
- ActiveQJ 990.3A-2011
- ReplacedNF EN ISO 2808-2007
- ActiveJJG 818-2018
- ActiveGB/T 1727-2021
- ActiveHG/T 20720-2020
- ActiveASTM B244-2021
- ActiveISO 2360-2017
- ActiveASTM D7091-2022
- ASTM E376-2019
- ActiveGB/T 13452.2-2008
- ActiveGB/T 11374-2012
- ActiveGB/T 4957-2003


DR270