Junengda MA6 high precision general Glossiness Meter
Junengda MA6 high-precision general-purpose Glossiness Meter is a fully intelligent Glossiness Meter that is self-calibrated at startup. The measurement Gloss is 0.0~199.5, and the light spot size of the MA6 Glossiness Meter is 9 × 18mm.
JND-
KSJ MG68-F2 intelligent Gloss meter, projection angle 60 °/85 °
Login -
Hypertherm GZ-268 Glossiness Meter 20 °/60 °/85 ° Three Angle Gloss Meter
$ 324.00 -
YINUO YN-GM Glossiness Determination of Glossiness
$ 1796.00 -
Metal Surface Glossiness Detection Instrument JFL-B60M JFL 60 Degree Glossiness Detection Instrument
$ 285.00 -
QILI MN268 three angle Glossmeter 20/60/85 ° three angle measurement Coating special
$ 661.00
MA6 Portable Gloss Meter is a portable gloss measuring instrument designed and manufactured in accordance with international standard ISO 2813 and Chinese national standard GB/T13891 GB9754 GB7706 GB8807. Its Specifications also meet the requirements of ASTM D2457 and ASTM D523 standards, and all performance indicators meet the requirements of the second-level working machine in the national standard JJG 696-2002 "Mirror Mirror Gloss Meter and Gloss Board".
Instrument gloss values are traceable to the gloss benchmarks of the Shanghai Institute of Metrology and Testing Technology (SIMT).

Application
Paint coatings, decoration materials, building materials, plastic materials, bamboo and wood products, ceramic products, metal polishing surface, electroplating surface, brushing surface, leather products, film paper, printing ink, stone and other material products in many fields and various Metal surface gloss measurement.

1. Numerical display window 2. On/off button 3. Adjustment button 4. Anti-slip rope perforation 5. Base 6. Calibration work board 7. Board value label
Advantages
1. Fully intelligent power-on self-calibration, high precision, high stability, instant measurement, simple and convenient operation.
2. With the new design of intelligent error compensation device, users can easily adjust without returning to the factory.
3. The measurement data has passed credible certification for five consecutive years and can be traced to the "SIMT" National Metrology and Verification Center.
4. Unique national first-level standard black (high) white (low) calibration plate, in line with national standards, can easily pass the metrological verification.
5. Using professional optical path design, the measurement data is stable and reliable, with minimal inter-stage difference and excellent reproducibility.
6. Patented ergonomic shell, one-time molding of high-end molds, anti-slip, lightweight, and resistant to a variety of solvents. (Patent No.: ZL 2014 3 0242920.5)
7. Pay attention to safety. High-end non-conductive shell is adopted, which has a high safety factor and avoids electric shock.
8. The power supply adopts imported high-end management chips, which can last up to 80 hours of continuous measurement on one charge, which is the most efficient in the industry.
9. Imported non-mechanical three-proof power switch is adopted, which has a long life and a good hand feeling.
10. The probe design with elliptical angle and soft surface can effectively prevent the measured object from being scratched during the measurement process.
Model Selection
| model | Measuring range | precision | grade | spot | power supply |
| Small and portable - without self-aligning base | |||||
| JND-A60 | 0.0~199.5GU | 0.5GU | National Standard Level 2 | Medium spot 36*18mm | Comes with built-in rechargeable battery |
| JND-P60 | 0.0~199.9GU | 0.1GU | National Standard Level 1 | ||
| JND-M60 | 0.0~199.9~1999GU (automatic switching) | 0.1/1GU | National Standard Level 2 | ||
| Ultra-Small Portable - Smart Self-Calibrating Stand | |||||
| MA6 | 0.0~199.5GU | 0.5GU | National Standard Level 2 | Small spot 9*18mm | Rechargeable or alkaline battery 1.2~1.5V (AA) No. 5 battery 1 piece |
| MP6 | 0.0~199.9GU | 0.1GU | National Standard Level 1 | ||
| MM6 | 0.0~199.9~1999GU (automatic switching) | 0.1/1GU | National Standard Level 2 | ||
| Ultra-small small hole curved surface portable - smart self-aligning base | |||||
| XA6 | 0.0~199.5GU | 0.5GU | National Standard Level 2 | Super small spot 1.5*3mm | Rechargeable or alkaline battery 1.2~1.5V (AA) No. 5 battery 1 piece |
| XP6 | 0.0~199.9GU | 0.1GU | National Standard Level 1 | ||
| XM6 | 0.0~199.9~1999GU (automatic switching) | 0.1/1GU | National Standard Level 2 | ||
| Small Portable - Classic Upgrade | |||||
| WGG60-E4 | 0.0~199.5GU | 0.5GU | National Standard Level 2 | Medium spot 36*18mm | Automatic built-in rechargeable battery |
| WGG60-Y4 | 0.0~199.9GU | 0.1GU | National Standard Level 1 | ||
| WGG60-EJ | 0.0~199.9~1999GU (automatic switching) | 0.1/1GU | National Standard Level 2 | ||
JND MA6 High precision Glossiness MeterSpecifications
| LIST | VALUE |
|---|---|
| Geometry | 60° |
| Measurement range | 0~199.5GU |
| Stability | 1GU |
| Error of indication | ±1.5GU |
| Division Value | 0.5GU |
| Zero Error | 0 |
| Measuring Areas | 9*18mm |
| Measurement port shape | ellipse |
| Standards | ISO 2813、GB/T9754、ASTM D2457、ASTM D523、GB/T13891、GB/T7706、GB/T8807、JJG 696 |
| Display | LCD display |
| Operating language | Chinese |
| Dimensions | 131*39*81mm |
| Weight | 186g |
| Power | 1.2~ 1.5V AA (No. 5) rechargeable or alkalinity battery |
| Operating Time | >80h |
| Operating Temperature | 15~40℃ |
| Environment Operating Humidity | < 85%, no condensation |
| Storage temperature | -10~60℃ |
JND MA6 High precision Glossiness Meter Packing list
1 host, 1 shockproof instrument bag, 1 set of intelligent calibrating base, 1 white work board (for verification), 1 user manual, 1 certificate of conformity, 1 warranty card, 1 lens cleaning cloth, 1 non-slip hand rope
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Gloss Meter - Coating Inspection Instrument Guide
- What gloss meter does the automotive, furniture, plastics and other industries choose?
- Frequently Asked Questions for Gloss Meters in 2022
- Gloss measurement and standard of paint film
- Surface painting mass detection and physicochemical performance measurement
- Gloss inspection method of slurry inks
- How to consider gloss when measuring color?
- How to measure gloss with a gloss meter?
- How to operate the different measurement modes of 3nh Sanenchi YG gloss meter?
- Junnengda MA6 Precision Gloss Meter How to measure gloss?
- IncomingGB/T 9754-2025
- ActiveGB/T 23454-2025
- ActiveGB/T 13217.2-2024
- ActiveSY/T 4106-2016
- Active 002-2017
- ActiveFZ/T 01097-2006
- AbolishGB/T 11420-1989
- ActiveGB/T 13448-2019
- ActiveHG/T 2006-2006
- ActiveGB/T 33876-2017
- ActiveGB/T 23997-2009
- ActiveHG/T 5370-2018
- ActiveHG/T 5183-2017
- ActiveHG/T 5180-2017
- ActiveASTM D3794-2022
- ActiveJJG 696-2015
- AbolishASTM F1843-2015
- ActiveASTM D1455-2023
- ActiveASTM D3928-2018
- ActiveISO 2813-2014


MA6
MP6
MM6