IKA MICROSTAR 7.5 controlled Stirrer 5L
IKA cantilever Stirrer, model MICROSTAR 7.5 control, with vibration detection function, can communicate via USB and Bluetooth, MICROSTAR 7.5 has a stirring volume of 5L and a stirring viscosity of 4000mPas.
IKA-
HUXI JB50-SH digital display constant speed powerbasic stirrer Circular six-hole fan blade Impeller blade 50mm Rod length 300mm
$ 368.00 -
CHIJIU MYP12-2-100W programmable Overhead Stirrer Stir power 100W
$ 323.00 -
RWD150 Strong Mechanical Stirring, Three Hole Fan Type Impeller Slurry 50mm Rod L400mm
$ 758.00 -
HUXI JB90-SH Laboratory Digital Display Stirrer Round Six Hole Fan Impeller Slurry 50mm Rod Length 500mm
$ 385.00 -
HUXI JB90-SH digital display constant speed powerbasic stirrer Four-blade Impeller blade 50mm Rod length 300mm
$ 383.00
Introduction
IKA's new MICROSTARS series: developed as a high-tech overhead agitator at the highest level of technology, the most compact for special applications.
Combining high performance with good detail in the smallest of spaces with a long-term warranty. Witness for yourself:
The "lightweight" in the smallest high-tech category, with little power but exceptional speed!
Features
Very good super high quality clear glass display
Vibration detection function with automatic shutdown in case of vibration of the overhead agitator
USB interface, e.g. for recording all parameters or firmware updates
Bluetooth function, which enables the combination of functions in the app
Simple connection with labworldsoft®
The measured temperature is displayed on a display
Viscosities up to 4,000 mPas and volumes up to 5 l are possible
Chemically resistant housing
Infinitely adjustable speed, 0/30 - 2,000 min-1
Microprocessor control system for constant speed as well as viscosity changes
Keylock (keylock button)
timer

Comparison of models of the IKA MICROSTAR Control series
| Model | MICROSTAR 7.5 control | MICROSTAR 10 control | MICROSTAR 20 control |
| Maximum stirring capacity (H2O) | 5 l | 10 l | 20 l |
| Motor input power | 32 W | ||
| Motor output power | 22 W | ||
| Motor principle | Brushless DC motor | ||
| Rotational speed display | LCD | ||
| Minimum speed | 30 rpm | ||
| Minimum speed | 0/30 rpm | ||
| Maximum rotational speed | 2000 rpm | 1000 rpm | 500 rpm |
| Maximum viscosity | 4000 mPas | 8000 mPas | 20000 mPas |
| Maximum output power of the stirring shaft | 15.7 W | ||
| Continuous operation time is allowed | 100% | ||
| Maximum torque of the stirring shaft | 7.5 Ncm | 15 Ncm | 30 Ncm |
| Maximum shaft torque (overload) at 60 rpm | 7.5 Ncm | 15 Ncm | 30 Ncm |
| At 100 rpm, the maximum torque of the mixing shaft | 7.5 Ncm | 15 Ncm | 30 Ncm |
| At 1000 rpm, the maximum torque of the stirring shaft | 7.5 Ncm | 15 Ncm | 30 Ncm |
| Maximum torque I | 7.5 Ncm | 15 Ncm | 30 Ncm |
| Speed range I (50 Hz) | 30 -2000 rpm | 30 - 1000 rpm | 30 - 500 rpm |
| Speed Range I (60 Hz) | 30 -2000 rpm | 30 - 1000 rpm | 30 - 500 rpm |
| Rotational speed control | Control knobs | ||
| Rotational speed setting accuracy | 1 ±rpm | ||
| n > Deviation of speed measurement at 300 rpm | 1 ±% | ||
| N < speed measurement deviation at 300 rpm | 3 ±rpm | ||
| The impeller is fixed | Rotary chuck | ||
| External temperature sensor interface | PT1000 | ||
| Temperature display | be | ||
| The minimum diameter of the rotor chuck clamping range | 0.5 - 8 mm | ||
| Hollow shaft, inner diameter | 8.5 mm | ||
| Hollow shaft (stop-state can be inserted) | be | ||
| Bracket fixation | Extension arm chuck fixation | ||
| Extension arm diameter | 13 mm | ||
| Extend the arm length | 160 mm | ||
| Torque display | be | ||
| Speed control | electronic | ||
| Rated torque | 0.075 Nm | 0.15 Nm | 0.3 Nm |
| Torque measurement | trend | ||
| Torque measurement deviation I | 3 ±Ncm | ||
| timer | be | ||
| Timer display | LCD | ||
| Time setting range | 0 - 6000 min | ||
| Temperature range | -10 - 350 °C | ||
| Temperature measurement accuracy | 0.1 K | ||
| Temperature measurement accuracy | PT1000 temperature deviation ± 0.5 (DIN IEC 751 Class A) K | ||
| Temperature sensor limit deviation | ≤ ± (0.15 + 0.002xITI) K | ||
| Housing material | Cast aluminium coating / thermoplastic polymer | ||
| Maximum remote distance (depending on building) | 150 m | ||
| Dimensions | 60 x 173 x 136 mm | ||
| weight | 1.657 kg | 1.26 kg | 1.663 kg |
| Allowable ambient temperature | 5 - 40 °C | ||
| Relative Humidity is allowed | 80% | ||
| DIN EN 60529 protection method | IP 54 | ||
| USB interface | be | ||
| Voltage | 100 - 240 V | ||
| frequency | 50/60 Hz | ||
| Instrument input power | 32 W | ||
| DC Voltage | 24 V= | ||
| Current consumption | 1300 mA | ||
IKA MICROSTAR 7.5 control Cantilever StirrerSpecifications
| LIST | VALUE |
|---|---|
| Rated Voltage | 100~240V |
| Rated Frequency | 50/60Hz |
| Input Power | 32W |
| output power | 22W |
| drive type | Brushless DC motor |
| Max Torque | 0.075Nm |
| Speed range | 30~2000rpm |
| Speed regulation mode | Control knob |
| Timer | without |
| Rotation speed display | LED |
| Impeller fixing method | Collet |
| Max Torque | 7.5N.cm |
| Rotary collet clamping range | Φ0.5~8mm |
| Processing Capacity | 5L |
| maximum viscosity | 4000mPa·s |
| Environmental temperature | 5~40℃ |
| Allowable Relative Humidity | ≤80% |
| Dimensions of the whole machine | 60*173*126mm |
| Machine Weight | 1.657kg |
| Shell material | Cast aluminum coating/thermal plasticity polymer |
IKA MICROSTAR 7.5 control Cantilever Stirrer Packing list
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- How to measure the chemical resistance of paint film?
- Onni full series Stirrer, disperse Mulser selection table [selection]
- Novel Stir - Non-Splash Stir
- How to determine the lacquer acid value for Paints and varnishes?
- Some introduction to shellac and shellac paint
- JB90-D type powerful electric Stirrer use and maintenance instructions
- How to choose Mulser?
- Development process of graphic analysis magneticstirrer
- Analysis of the characteristics and working principle of laboratory Stirrer
- Application of RK Scraper in Spreader paper whiteness performance test


MICROSTAR 7.5 control