JND MM6 Large range metal gloss meter Gloss range 0.0~1999GU
JND MM6 metal gloss meter is a smart large-range metal gloss meter with a measurement range of 0.0~1999GU and a projection angle of 60 °. MM6 conforms to ISO 2813 and GB/T9754 standards.
JND-
3NH YG60S 60 ° Single Angle Glossiness Meter
$ 161.00 -
JND MS6 Stone special Glossiness Meter
$ 223.00 -
Junengda JND-A60 high precision general Glossiness Meter
$ 234.00 -
IWAVE WG60 Glossmeter 60 ° inks paints, wood, marble, granite, ceramics, plastics, paper, etc
$ 270.00 -
Glossmeter AMITTARI AG-1268B 20 °, 60 ° and 85 ° three-angle portable Glossmeter
$ 382.00
MM6 portable gloss meter is a portable gloss meter designed and manufactured in accordance with the international standard ISO 2813 and Chinese national standards GB/T13891 GB9754 GB7706 GB8807. Its technical parameters comply with the provisions of ASTM D2457 and ASTM D523 standards at the same time, and all performance indicators meet the requirements of the second-level working machine in the national standard JJG 696-2002 "Mirror Image Glossmeter and Glossiness Plate" metrological verification regulations.
The gloss value of the instrument is traceable to the glossiness benchmark of the Shanghai Institute of Metrology and Testing Technology (SIMT).










JND MM6 Gloss meterSpecifications
| LIST | VALUE |
|---|---|
| Measurement angle | 60° |
| Measurement range | 0~1999GU |
| Measuring Areas | 9*18mm |
| Error of indication | ±1.0GU(0.0~199.9)/±1.5%GU(200~1999) |
| Graduation | 0.1GU|1GU |
| Standards | ISO 2813 GB/T13891 GB9754 GB7706 GB8807 |
| Operating language | Chinese |
| Dimensions | 131*39*81mm |
| Weight | 186g |
| Power | 1.2~ 1.5V AA (No. 5) rechargeable or alkaline battery |
| Zero Error | 0GU |
| Stability | 0.4GU(0.0~199.9)/1GU(200~1999) |
| Operating Time | >80h |
JND MM6 Gloss meter Packing list
Host x1, shockproof instrument bag x1, intelligent calibrating base x1, mirror work plate (for verification) x1, white work plate (for verification) x1, user manual x1, certificate x1, warranty card x1, lens cleaning cloth x1, anti-skid hand rope x1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Cause Analysis and Treatment of Poor Film Surface Glossiness
- Coating Gloss Determination
- Glossmeter Classification and Measurement principle
- [Film Properties and Measurements] - film fog shadow determination
- Gloss measurement: High Gloss, Medium Gloss to Low Gloss
- What is a gloss meter?
- Principle and application analysis of microporous gloss meter
- How is Film Gloss Measured?
- The importance of gloss meters in professional painting
- Determination of Film Gloss (glossiness)
- ActiveGB/T 13217.2-2024
- ActiveGB/T 13448-2019
- ActiveGB/T 21867.3-2008
- ActiveASTM D2457-2021
- ActiveGB/T 13891-2008
- ActiveGB/T 9754-2007
- ActiveISO 2813-2014
- AbolishJB/T 7706-1995
- AbolishGB/T 9754-1988


MM6