      Home> Viscosity Cup> Moderner> Moderner ISO-4 ISO Flow Cup

      MODERNER ISO-4 ISO Flow Cup inks Viscosity Cup

      Viscosity range 35~ 135cSt, outflow time 30~100s, flow hole diameter 4mm, cup body material anodic oxidation aluminum, filter material brass, applicable to standard ISO 2431.

      Brand
      SKU: NB021792
      China Moderner
      Stock
      Loading…
      Price
      Please contact customer service
      Promotion
      Service
        Service
        The delivery and service By NBchao.Com
        VS
        Genuinegoods
        • Moderner ISO-4 ISO Flow CupOverview

        • Specifications
        • Comments
        • FAQs
        ISO-4
        ISO Flow Cup
        • MODERNER ISO-4 ISO Flow Cup inks Viscosity Cup
        • MODERNER ISO-4 ISO Flow Cup inks Viscosity Cup Figure 1
        Viscosity range 35~ 135cSt, outflow time 30~100s, flow hole diameter 4mm, cup body material anodic oxidation aluminum, filter material brass, applicable to standard ISO 2431.

        The ISO outFlow Cup is used to determine the outflow time of paints with Newtonian or near-Newtonian fluids. The range of kinematic viscosity suitable for testing samples is 7-685mm2/s. The ISO outFlow Cup conforms to the national standard GB/T6753.4 Paint and varnish Use the outFlow Cup to measure the outflow time.

        Test Range

        cup numberKinematic Viscosity Test Rangecalculation method
        ISO-37~40mm2/sv=0.443t-200/t
        ISO-435~135mm2/sv=1.37t-200/t
        ISO-5100~300mm2/sv=3.28t-220/t
        ISO-6220~685mm2/sv=6.9t-570/t

        In the formula: v——kinematic viscosity mm2/s

        t——Outflow time s (measured value should be within 30~100s)


        preliminary test

        1. Choose a certain label outFlow Cup, so that the sample outflow time in the cup is within 30-100s.

        2. Before each measurement, wipe the outFlow Cup with a silk cloth dipped in solvent and dry it. The leak nozzle should be clean when observing the light.

        3. Adjust the level screw to make the end surface of the outFlow Cup level. in no airflow.


        Use and maintenance

        1. Place a container under the outFlow Cup, block the outflow hole with your hands, and slowly fill the outFlow Cup with the sample to avoid air bubbles. When the sample is filled with a convex surface and begins to overflow, use a straight-edged scraper or a flat glass plate to slide and push it along the upper edge to scrape off air bubbles and excess samples. Release the finger to allow the sample to flow, that is, start the stopwatch, and stop the stopwatch when the sample flow is interrupted for the first time. The total time that the sample flows out of the outFlow Cup is the outflow time of the sample. The difference between the two measured values should be less than 4% of the average value.

        2. If the calibrated cup is used as a standard cup, it should be multiplied by a correction factor (k) value to correct the outflow time deviation.

        3. The temperature of the sample is 25°C±0.5°C during the measurement, and it should be measured in a constant temperature room. If the test is not carried out in a constant temperature room, a thermometer should be placed in the sample stream, and the temperature shown should be kept the same as the temperature before the outflow. more than 0.5°C.

        4. After the test, the outFlow Cup should be wiped clean with solvent and coated with anti-rust oil. Do not use any sharp and hard metal objects when wiping to prevent scratching the surface.


        VS

        Moderner ISO-4 ISO Flow CupSpecifications

        LIST VALUE
        Viscosity range 35~135cSt
        outflow time 30~100s
        Flow hole diameter 4mm
        Cup body material Aluminum anode oxidation
        Filter material Brass
        Applicable standard ISO 2431

        Moderner ISO-4 ISO Flow Cup Packing list

        Column frame X1, viscosity cup X1, manual X1

        [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

        FAQ

        [Q]
        Measure the viscosity of the Coating, about 50mm ²/s, which flow cup should be selected?
        [A]
        It is recommended that you use an ISO-4 flow cup because its test range is 35 to 135mm ²/s, which exactly covers the 50mm ²/s viscosity you mentioned. The measured outflow time will be between 30 and 100 seconds, resulting in more accurate results.
        [Q]
        Our laboratory mainly tests the flowability of paints. Is ISO flow cup suitable?
        [A]
        Appropriate, ISO flow cup is designed to measure the outflow time of Newtonian fluids such as coatings and varnishes. It is commonly used in paints and inks industries to quickly judge viscosity, and the operation is simple and meets international standards.
        [Q]
        Which kinematic viscosity range is the ISO flow cup suitable for?
        [A]
        The ISO flow cup is suitable for the kinematic viscosity range of the test sample from 7 to 685mm2/s. The ISO flow cup is mainly used to determine the outflow time of fluids with Newtonian or near Newtonian type.
        [Q]
        What is the test viscosity range of ISO4 flow cup in modern environment?
        [A]
        Hello, the viscosity range is 35~ 135mm2/s.
        [Q]
        Does this ISO flow cup have any requirements for the tested environment temperature?
        [A]
        Hello, yes, the temperature range is 25 ° C ± 0.5 ° C, which should be measured in a constant greenhouse. If the test is not carried out in a constant greenhouse, a thermometer should be placed in the sample beam, and the temperature shown should not exceed 0.5 ° C.