MODERNER DC0530 Thermostatic Bath -5~ 100 ℃
MODERNER DC0530 Thermostatic Bath Temperature range is -5~ 100 ℃, small fluctuation, only +/- 0.05 ℃. DC0530 is a low temperature thermostatic circulating bath with a 30L volume working tank, using internal and external pump circulation mode, Heating power is 2KW.
Moderner-
HLM-4005 Magnetic Stirring Low Temperature Reaction Tank
$ 1485.00 -
YUEPING CH-1015 Thermostatic Bath Temperature range: room temperature + 8~ 100 ℃ accuracy up to 0.1 degrees
$ 350.00 -
Guohua HH-601 super constant temperature Water Bath domestic (CN) circulation
$ 349.00 -
NELE GDH-4030 Ultra high accuracy Thermostatic Bath 30L/-40 ℃
$ 4196.00 -
YIHENG MPG-40C desktop thermostatic Water Bath temperature range is -40~100 ℃ Power 3100W
$ 1967.00
Introduction
XD-26-DC series low-temperature Constant Temperature Circulating Bath (low-temperature constant temperature bath) adopts new high-performance single-chip microcomputer control, self-tuning PID adjustment, imported temperature sensor temperature measurement, high temperature control accuracy and small fluctuation; adopts high-quality refrigeration compressor (Some models are fully imported brand compressors or compressor units), with high refrigeration efficiency, fast cooling, and low noise; they use a good fully sealed mixing motor, the lubricating grease is not easy to volatilize, and they have low noise and long life. The DC series uses a large-screen backlit LCD display, with all parameters clear, beautiful and stylish.
The low-temperature constant-temperature circulating bath (low-temperature constant temperature bath) can not only conduct constant temperature tests directly in the Water Tank, but also use the external circulation function to guide the controlled constant-temperature liquid in the bath to other equipment through hoses connected to other equipment.
Application
Thermometer calibration, supporting viscometer, density meter, surface tensIon Meter, polarimeter, rotary evaporator, Spectrophotometer , etc.
main feature
1. Adopt high-performance single-chip microcomputer control, PID adjustment, and self-tuning control technology, with high temperature control accuracy and short stabilization time;
2. The liquid level protection device can prevent various failures caused by empty heating of the heating tube;
3. The upper limit over-temperature alarm function can be set by yourself. If it exceeds the range, it will alarm immediately;
4. High-performance stirring motor makes temperature fluctuations more uniform, low noise, low heat, fully enclosed, and long life;
5. Large screen backlit LCD, all parameters are clear and beautiful;
6. The circulation pump can lead the constant-temperature liquid in the tank to establish a second constant-temperature field;
7. The inner tank and countertop are made of high-quality stainless steel, which is corrosion-resistant and easy to clean;
8. The DC series is an ordinary low-temperature constant temperature bath with a temperature control accuracy of 0.1℃ and a fluctuation of 0.05℃. The temperature range is from -80℃ to 100℃ and the volume is 6 liters, 15 liters, 20 liters, and 30 liters. Using large-screen backlit LCD, all parameters are clear and clear.

DC low temperature thermostatic bath series parameter comparison
| model | Working temperature range (℃) | Fluctuation (℃) | Resolution (℃) | Volume (L) | Opening size mm (length*width*depth) | Low level protection | cycle mode | Pump flow L/min | Heating power (KW) | Opening size mm (length*width*depth) | Net weightKg |
| XD-26-DC0506 | -5~100 | 0.05 | 0.1 | 6 | 145*145*150 | have | inside and outside | 10 | 0.8 | 340*400*680 | 29 |
| XD-26-DC1006 | -10~100 | 0.05 | 0.1 | 6 | 145*145*150 | have | inside and outside | 10 | 0.8 | 340*400*680 | 29 |
| XD-26-DC2006 | -20~100 | 0.05 | 0.1 | 6 | 145*145*150 | have | inside and outside | 10 | 0.8 | 340*400*680 | 32 |
| XD-26-DC3006 | -30~100 | 0.05 | 0.1 | 6 | 145*145*150 | have | inside and outside | 10 | 0.8 | 340*400*680 | 38 |
| XD-26-DC4006 | -40~100 | 0.05 | 0.1 | 6 | 145*145*150 | have | inside and outside | 10 | 1 | 340*400*680 | 40 |
| XD-26-DC0515 | -5~100 | 0.05 | 0.1 | 15 | 235*140*180 | have | inside and outside | 10 | 1 | 340*400*680 | 33 |
| XD-26-DC1015 | -10~100 | 0.05 | 0.1 | 15 | 235*140*180 | have | inside and outside | 10 | 1 | 340*400*680 | 33 |
| XD-26-DC2015 | -20~100 | 0.05 | 0.1 | 15 | 235*140*180 | have | inside and outside | 10 | 1 | 340*400*680 | 35 |
| XD-26-DC3015 | -30~100 | 0.05 | 0.1 | 15 | 235*140*180 | have | inside and outside | 10 | 1.2 | 370*440*730 | 41 |
| XD-26-DC4015 | -40~100 | 0.05 | 0.1 | 15 | 235*140*180 | have | inside and outside | 10 | 1.5 | 370*440*730 | 43 |
| XD-26-DC0530 | -5~100 | 0.05 | 0.1 | 30 | 290*300*200 | have | inside and outside | 10 | 2 | 440*600*1100 | 59 |
| XD-26-DC1030 | -10~100 | 0.05 | 0.1 | 30 | 290*300*200 | have | inside and outside | 10 | 2 | 440*600*1100 | 62 |
| XD-26-DC2030 | -20~100 | 0.05 | 0.1 | 30 | 290*300*200 | have | inside and outside | 10 | 2 | 440*600*1100 | 62 |
| XD-26-DC3030 | -30~100 | 0.05 | 0.1 | 30 | 290*300*200 | have | inside and outside | 10 | 2 | 440*600*1100 | 68 |
| XD-26-DC4030 | -40~100 | 0.05 | 0.1 | 30 | 290*300*200 | have | inside and outside | 10 | 2 | 440*600*1100 | 70 |
Moderner DC0530 Thermostatic BathSpecifications
| LIST | VALUE |
|---|---|
| Temperature range | -5~100℃ |
| Temperature control mode | Self tuning PID |
| Temperature Fluctuation | 0.05℃ |
| Temperature Resolution | 0.1℃ |
| Temperature transducer | Imported temperature transducer |
| Tank Volume | 30L |
| Tank opening Dimensions | 290*300*200mm |
| Tank Material | stainless steel |
| number of holes | single hole |
| Circular mode | Internal/external circulation |
| Flow rate of pump | 10L/min |
| Total Power | 2kw |
| Dimensions | 440*600*1100mm |
| Net Weight | 59kg |
Moderner DC0530 Thermostatic Bath Packing list
machine X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveGB/T 26809-2011
- ActiveGB/T 26808-2011
- ActiveFZ/T 50010.3-2011
- ActiveJB/T 5376-1991
- ActiveGB 9278-2008
- ActiveGB/T 5561-2012


DC0530